5.

OPERATION

5.1.   

OPERATING THE GUN

‰

WARNING!

 Ensure that the trigger is not depressed before opening the nozzle valve.

5.1.1.

  

Press the Reset button for 1 sec to zero the display.

5.1.2.

  

With the nozzle pointing into the receiving container, open the nozzle valve as shown in fig.1.

5.1.3.

  

Depress the trigger and dispense the liquid the amount dispensed is shown on the display (fig.2.4).

5.1.4.

 

Release trigger and close the nozzle valve.

5.2.   

LCD INTERFACE USAGE

5.2.1.

  

User Buttons (fig.5) 

  

1. LCD displays delivery volume and totals
2. Units: L, GAL, PT, QT
3. Two decimal place values
4. Low battery indicator
5. MOVE and RESET buttons

5.2.2.

  

Display key (fig.6)

1. Volume since last RESET
2. Battery state
3. Calibration mode indicator

 

4. Reset to zero indicator

5. Total register
6. Flow rate mode
7. Units (Lts/gall/pint/quart)

5.2.3.

  

MOVE / RESET Usage (fig.5.5)

 MOVE key enters ‘calibration’ mode
 RESET key for register and total 

 

Both keys pressed enters ‘configuration’ mode

5.2.4.

  

To RESET current total (fig.7)

From standby press RESET
All segments light up
Current total resets to 0.00

5.2.5.

To display correction factor and To

tal (fig.8) 

Hold MOVE and RESET for 3 seconds
Value “1.4000” is correction factor.
”1234567” overall total

5.2.6.

  

To change Units (fig.9)

Hold MOVE and RESET for several seconds

Area 2 in fig.5 shows units

Press RESET to change units

 

Press and hold MOVE to confirm choice

5.3.   

DETERMINING THE CORRECTION FACTOR

5.3.1.  

Dispense at least 1 litre of liquid into a calibrated container.

5.3.2.

Record the quantity of liquid in the container and record the quantity of 
liquid dispensed as indicated on the meter display. Press the 

 

Move + Reset buttons (fig.5.5 and fig.5.5) simultaneously to display 

the current correction factor.

Qty Dispensed

Qty Indicated

x  Current Correction Factor = New Correction Factor.

5.4.   

ALTERING CORRECTION FACTOR DIRECTLY

5.4.1.

  

Wait for meter to go to standby (fig.10).

5.4.2.

Reset total (5.2.4)

 fig.11 to zero.

5.4.3.

Press and hold MOVE key until all digits illuminate and display 

 

shows ‘Cal’ (fig.12).

5.4.4.

  

Press RESET to set digit values (from right to left) (fig.13).

5.4.5.

Once value is correct hold down MOVE key until Cal mode quits.

Original Language Version

© Jack Sealey Limited

fig.4

fig.5

fig.6

fig.7

fig.9

AK4562D  Issue 3 (H, 5, F)  24/09/18

fig.11

fig.10

fig.8

Summary of Contents for AK4562

Page 1: ...nnect air pressure from equipment when not in use 8 DO NOT exceed the maximum air pressure of 115psi 8 DO NOT point the nozzle at people or animals 8 DO NOT use the equipment near open flames 8 DO NOT smoke whilst using this equipment 8 DO NOT use to extract corrosive fluids 8 DO NOT dismantle tamper with or adapt the pump for any purpose other than for which it is designed 8 DO NOT use the unit i...

Page 2: ...the base plate and secure using four bolts washers and nuts not shown in fig 1 4 2 PUMP AND AIR REGULATOR LUBRICATOR ASSEMBLY 4 2 1 Apply a small amount of liquid thread sealant onto the threads of the air inlet of the pump and attach the air regulator lubricator fig 2 WARNING DO NOT allow thread sealant to enter the pump 4 2 2 Attach the outlet pipe to the male outlet thread on the pump and attac...

Page 3: ...urrent total resets to 0 00 5 2 5 To display correction factor and Total fig 8 Hold MOVE and RESET for 3 seconds Value 1 4000 is correction factor 1234567 overall total 5 2 6 To change Units fig 9 Hold MOVE and RESET for several seconds Area 2 in fig 5 shows units Press RESET to change units Press and hold MOVE to confirm choice 5 3 DETERMINING THE CORRECTION FACTOR 5 3 1 Dispense at least 1 litre...

Page 4: ...es sealey co uk www sealey co uk ENVIRONMENT PROTECTION Recycle unwanted materials instead of disposing of them as waste All tools accessories and packaging should be sorted taken to a recycling centre and disposed of in a manner which is compatible with the environment When the product becomes completely unserviceable and requires disposal drain any fluids if applicable into approved containers a...

Reviews: