background image

INSTRUCTIONS FOR 

ELECTRONIC VERNIER CALLIPER 

Model No: AK962EV.V2

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according

to these instructions and properly maintained, give you years of trouble free performance.

IMPORTANT

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL

REQUIREMENTS, WARNINGS, AND CAUTIONS. USE THIS PRODUCT CORRECTLY AND

WITH CARE, FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY

CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY.

p

p

WARNING! Ensure Health and Safety, local authority and general workshop practice regulations 

are adhered to when using tools and equipment.

7

DO NOT

use calliper if damaged.

3

Maintain calliper in good and clean condition for best and safest performance.

3

Keep the work area clean, uncluttered and ensure there is adequate lighting.

3

Maintain correct balance and footing. Ensure the floor is not slippery and wear non-slip shoes.

3

Keep children and unauthorised persons away from the work area.

1. SAFETY INSTRUCTIONS

2. INTRODUCTION & SPECIFICATION

Hardened and tempered stainless steel calliper with satin finish. 11mm High figures in LCD display for ease of

reading. Metric and Imperial calibration with conversion between the two. Zero setting control allows for

comparative measurement. Supplied in carry-case.

p

p

WARNING! Ensure Health and Safety, local authority and general workshop practice regulations 

are adhered to when using tools and equipment.

7

DO NOT

use calliper if damaged.

3

Maintain calliper in good and clean condition for best and safest performance.

3

Keep the work area clean, uncluttered and ensure there is adequate lighting.

3

Maintain correct balance and footing. Ensure the floor is not slippery and wear non-slip shoes.

3

Keep children and unauthorised persons away from the work area.

1. SAFETY INSTRUCTIONS

2. INTRODUCTION & SPECIFICATION

Hardened and tempered stainless steel calliper with satin finish. 11mm High figures in LCD display for ease of

reading. Metric and Imperial calibration with conversion between the two. Zero setting control allows for

comparative measurement. Supplied in carry-case.

Specification

Resolution                                             0.01mm (0.0005”)

Range                                                   150mm (6”)

Accuracy                                               ±0.02mm (±0.001”) @ <100mm      ±0.03mm (±0.001”) @ >100mm

Repeatability                                          0.01mm (0.0005”)

Functions                                               Zero set, mm/inch select, incremental zero, ABS

Messages                                              Flashing display = replace battery 

Battery life                                              Approx. two years (approx. one year in continuous service)

Battery                                                   SR44 - 1.55V

Operational Temperature range                5 - 40

O

C

1 Internal Measure

5  LCD Display

9       Battery Cover

2 Metric/Imperial Selector

6

External Measure

10     Depth Measure

3 Locking Screw

7

On/Off Control

11     Step Measure

4 ABS/0 Switch

8

Zero Control

1 Internal Measure

5  LCD Display

9       Battery Cover

2 Metric/Imperial Selector

6

External Measure

10     Depth Measure

3 Locking Screw

7

On/Off Control

11     Step Measure

4 ABS/0 Switch

8

Zero Control

AK962EV.V2 - (2) - 191005

AK962EV.V2 - (2) - 191005

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according

to these instructions and properly maintained, give you years of trouble free performance.

IMPORTANT

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL

REQUIREMENTS, WARNINGS, AND CAUTIONS. USE THIS PRODUCT CORRECTLY AND

WITH CARE, FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY

CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY.

INSTRUCTIONS FOR 

ELECTRONIC VERNIER CALLIPER 

Model No: AK962EV.V2

Specification

Resolution                                             0.01mm (0.0005”)

Range                                                   150mm (6”)

Accuracy                                               ±0.02mm (±0.001”) @ <100mm      ±0.03mm (±0.001”) @ >100mm

Repeatability                                          0.01mm (0.0005”)

Functions                                               Zero set, mm/inch select, incremental zero, ABS

Messages                                              Flashing display = replace battery 

Battery life                                              Approx. two years (approx. one year in continuous service)

Battery                                                   SR44 - 1.55V

Operational Temperature range                5 - 40

O

C

Reviews: