8. INSTALLATION - ELECTROSPOT 9500
!
!
WARNING! Unplug from mains power supply before connecting cables and accessories.
8.1.
ELECTRICAL CONNECTION
Ensure that the machine is compatible with your mains supply.
8.2.
COOLANT (for water cooled clamp, arms)
8.2.1
Connect the coolant pipes to the water cooler, as shown in fig. 6.
8.2.2. Fill cooler with distilled water (approx. 5 litres).
8.2.3. Open vent plug (fig. 6.A) and run pump until all air is expelled - close plug.
8.3.
PNEUMATIC CLAMP CONNECTION (fig. 7)
8.3.1. Fit the cable connectors to the welder output plates and rotate to engage (fig.7.1).
8.3.2. Retain by tightening the lower nuts.
8.3.3. Connect the control cable and the two air lines (fig. 7.2).
8.4.
MANUAL CLAMP, CLAMP STUDDER & GROUND CABLE CONNECTION (fig. 8)
8.4.1. Connect the two Dinse adaptors to the welder output plates.
8.4.2. Plug the Dinse plugs into the adaptors and connect the control cable.
8.5.
AIR PULLER & GROUND CABLE CONNECTION (fig. 9)
8.5.1. Connect the two Dinse adaptors to
the welder output plates.
8.5.2. Connect the two Dinse plugs into
the adaptors.
8.5.3. Plug air-line from puller into welder
air outlet and connect control cable.
8.6.
DOUBLE SPOT CLAMP
CONNECTION
Proceed as for the Pneumatic
Clamp but note that there is
only one air line to connect.
9. FRONT PANEL - ELECTROSPOT 9500
fig. 8
fig. 10
9.1.
The following describes the functions of the key buttons
and the meanings of symbols, and refers to fig. 10.
Key 3
Key 1
Key 2
Key 4
7
5
fig. 7
fig. 9
Selects the appropriate sheet thickness and gives
access to the programming mode. See Section 9.2.
Adjusts the spot welding time above or below the
default setting and, in the programming mode, selects
welding current. See Section 9.2.
fig. 6
6
ElectroSpot 8000/9500.V2 - 2 - 040903