background image

 

8

  

DO NOT

 over-fill fuel tank. Always leave room for fuel to expand.

 

8

  

DO NOT

 operate in the rain.

 

  

DANGER

! Do not tamper with the engine governed speed setting. Higher operating speeds are dangerous and increase    

  the risk of personal injury and/or equipment damage. The generator supplies the correct rated frequencies and voltage only  

  when running at the correct governed speed. Incorrect frequency and/or voltage can damage some connected electrical    

  loads. Operating at excessively low speeds may result in shortened engine life. Over-speeding will invalidate the warranty.

 

8

  

DO NOT

 operate the generator when you are tired, or under the influence of alcohol, drugs or intoxicating medication.

 

8

  

DO NOT

 store generator with fuel in tank where petrol vapours might reach an open flame or spark.

2.  INTRODUCTION

Heavy duty frame design provides full protection and portability. Suitable for running power tools and lighting units. Long running with 

up to 12 hours on a full tank. Fitted with one 230V 16A and one 110V 16A socket. Powerful and reliable generator. Smooth running 

unit fitted with anti-vibration engine mounts. Features low oil warning light, overload protection and fuel gauge.

3.  SPECIFICATION

Model no: .................................................................... G3801

Motor power: ................................................................. 9.2hp

Motor type: ...................................................... 4-stroke petrol

Output: ............................................................... 230V - 50Hz

Current rating: ..........................................................15.2/16A

Continuous power rating: ...................................3500/1800W

Maximum power rating: ......................................3800/2000W

Fuel capacity: ..................................................................25ltr

Maximum running time: ...................................................12hr

Noise rating: ....................................................... 80dB@ 7mtr

Dry weight: ..................................................................... 64kg

Dimensions (W x D x H): .........................685 x 540 x 535mm

Key for figures 1-10

1 Tank indicator

2 Tank lid

3A 110V 16A socket

3B 230V 16A socket

3C Socket selection switch

4 Earth connection

5 Overload cut-out

6 Voltmeter

7 Oil filler plug

8 Oil drain plug

9 Oil shortage cut-out switch

9A Oil shortage cut-out light

10 On/Off switch

11 Choke lever

12 Recoil starter

13 Petrol tap

14 Wheels

15 Axle

16 Foot

17 Push bar holder

18 Push bar

19 Screws size M8 x 40

19a Screws size M8 x 40

20 Screws size M8 x 16

21 Washers for wheels

22 Securing split pins for wheels

23 Nuts M8

24 Screwdriver

25 Spark plug wrench

26 Oil filler funnel

G3801 | Issue 1- 24/06/16

Original Language Version

© Jack Sealey Limited

3

1

2

Summary of Contents for G3801

Page 1: ...n fire or an explosion No user performed modifications including venting of the exhaust and or cooling ventilation will eliminate the danger DANGER If this unit is used for back up power in the event of a commercial power failure the following steps must be taken Before connecting the generator to the electrical system open the main circuit breaker to isolate the generator and system from the comm...

Page 2: ...nk Fitted with one 230V 16A and one 110V 16A socket Powerful and reliable generator Smooth running unit fitted with anti vibration engine mounts Features low oil warning light overload protection and fuel gauge 3 SPECIFICATION Model no G3801 Motor power 9 2hp Motor type 4 stroke petrol Output 230V 50Hz Current rating 15 2 16A Continuous power rating 3500 1800W Maximum power rating 3800 2000W Fuel ...

Page 3: ...G3801 Issue 1 24 06 16 Original Language Version Jack Sealey Limited 4 5 6 7 8 9 10 11 ...

Page 4: ...or see fig 3 4 and the other end to an external earth for example an earthing rod 6 OPERATION Important You must fill up with engine oil approx 1 1ltr and fuel before you can start the engine See 7 4 and fig 10 Oil shortage light will illuminate if engine oil is low see fig 3 9A 6 1 Make sure that the generator has sufficient ventilation 6 2 Make sure that the ignition cable is secured to the spar...

Page 5: ...he equipment regularly with a moist cloth and some soft soap Do not use cleaning agents or solvents these could attack the plastic parts of the equipment Ensure that no water can seep into the device 7 2 Air filter see figs 11 12 7 2 1 Clean the air filter at regular intervals and replace it if necessary 7 2 2 Open both clips see fig 11 A and remove the air filter cover see fig 11 B 7 2 3 Remove t...

Reviews: