5. STORAGE OF MORE THAN 30 DAYS
Note: If you store the generator for more than 30 days it is essential to protect the fuel system. This can be done by draining
all the fuel or by adding a fuel additive to prevent fuel gum deposits from forming.
Note: Store the generator in a safe, dry, childproof area, free of excessive humidity and dust.
WARNING! Petrol is highly flammable and petrol vapour is explosive. Do not permit smoking, naked flames, sparks or heat
in the vicinity while handling petrol. Avoid spilling petrol onto a hot engine. Comply with all laws regulating storage and
handling of fuels.
5.1
CLEAN
5.1.1
Remove debris and dust accumulations from the generating set surfaces.
5.2
DRAINING ALL THE FUEL
5.2.1
Turn the fuel valve On and siphon the fuel into an approved container.
5.3
USING A FUEL ADDITIVE
5.3.1
Fill the fuel tank with fresh fuel.
Note: If only partially filled, air in the tank will promote fuel deterioration during storage.
5.3.2
Add the fuel stabiliser following the manufacturer’s instructions.
5.3.3
Run the engine outdoors for ten minutes to ensure that all untreated fuel has been used.
5.3.4
Stop the engine and move the fuel valve to the OFF position.
5.4
BORE LUBRICATION
5.4.1
Remove the spark plug and pour approximately 25ml of clean engine oil into the cylinder.
5.4.2 crank the engine several times in order to circulate the the oil into the cylinder, then refit the spark plug.
5.4.3
Slowly pull the recoil starter cord until some resistance is felt, then keep pulling until the arrow on the starter pulley aligns with the hole
on the recoil starter.
6. TROUBLESHOOTING
PROBLEM
CAUSE
REMEDY
engine will not start
Fuel tap not turned on
Turn fuel on
no fuel in tank
Fill fuel tank
engine run switch not turned on
Switch to On position
choke not set correctly
Adjust choke position
Spark plug fouled
clean/replace spark plug
Air filter blocked
Clean/replace air filter
engine runs rough
Air filter blocked
Clean/replace air filter
Spark plug fouled
clean/replace spark plug
choke not set correctly
Adjust choke position
Dirty/stale fuel
Drain and replace fuel
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT:
no liability is accepted for incorrect use of this product.
WARRANTY:
Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION:
For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
01284 757500
01284 703534
sales@sealey.co.uk
Sole UK Distributor, Sealey Group,
Kempson Way, Suffolk Business Park
,
Bury St. edmunds, Suffolk,
IP32 7AR
www.sealey.co.uk
Web
Original Language Version
GG0720 Issue: 2 - 14/10/09