5.  Maintenance

risk of Hand arm Vibration injury. 

The 

Gsa6000

 Air Impact Wrench, when operated in accordance with these instructions and tested in accordance with 

EN 28662-2: 1994 results in the following vibration emission declared in accordance with  BS EN12096: 1996. 

Gsa6000

 Measured vibration emission value: ......8.9m/s

2

  

Uncertainty:  ..............................................3.5m/s

2

these values are suitable for comparison with emission levels of other tools that have been subject to the same 

test.

this tool may cause hand-arm vibration syndrome if its use is inadequately managed.

recommended Measures to reduce risk of hand-arm vibration syndrome:

This tool should not be used by an individual regularly for more than 77 minutes in any 8 hour period.

This duration of use should be reduced if the individual is exposed to hand-arm vibration from other sources.

 

WarninG!

 

Disconnect wrench    

 

from air supply before changing  

 

 

accessories, servicing or 

 

performing maintenance.

 

 

Replace or repair damaged parts.  

 

Use genuine parts only.  

 

 

Unauthorised parts may be  

 

 

dangerous and will invalidate the  

 

 

warranty.

5.1

  If the air system does not have an  

 

oiler lubricate the air wrench daily  

 

with a few drops of Sealey air tool  

 

oil dripped into the air inlet. 

5.2

  Check and top up the gearbox by  

 

removing grub screw located under  

 

the impact head.

5.3

   Clean the wrench after use. 

 

Do not

 use worn, or damaged sockets.

5.4

   Loss of power or erratic action may be due to the following:

 

a)

  Excessive drain on the air line. Moisture or restriction in the air pipe. Incorrect size or  

 

  type of hose connectors. To remedy check the air supply and follow instructions in  

 

  chapter 3. 

 

b

)  Grit or gum deposits in the wrench may also reduce performance. If your model has an  

 

  air strainer (located in the area of the air inlet), remove the strainer and clean it. Flush  

 

  the wrench out with gum solvent oil or an equal mixture of SAE No 10 oil and paraffin.  

 

  Allow to dry before use. 

5.5

  For a full service contact your local Sealey service agent.

5.6

  When not in use, disconnect from air supply, clean wrench and store in a safe, dry,    

 

childproof location.

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

iMPortant: 

No liability is accepted for incorrect use of this product. 

Warranty: 

Guarantee is 12 months from purchase date, proof of which will be required for any claim. 

inforMation:

 For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

sales@sealey.co.uk

sole uK Distributor, sealey Group, 

Kempson Way, Suffolk Business Park

Bury St. Edmunds, Suffolk,

IP32 7AR

www.sealey.co.uk

Web

email

Original Language Version

GSA6000   Issue: 3 - 14/12/11

Reviews: