model No
IFSH1809R
IFSH1809lR
Power:
1800W
1800W
Input supply:
230V 50Hz 13A
230V 50Hz 13A
Dimensions (W x H x D):
650 x 200 x 240mm
890 x 200 x 240mm
minimum / maximum Height:
1530mm / 1850mm
1530mm / 1850mm
lED Quantity:
-
40
3. MOUNTING INSTALLATION
3.1 Assembly (fig.1).
3.2
Insert the welded plate end of section 9 into the base 10 and
secure using washer 11 and screw 12.
3.3
Silde section 8 onto section 9 and secure using screw 14. Slide section
5 upwards from inside of section 7, turn lock screw 6 clockwise to secure
and then slide section 7 onto section 8 and secure with screw 14.
3.4
Insert the end of section 5 into the base of the heater 1 and secure with
screw 13.
3.5
Align Clip 3 to the holes in sections 7 and 9 and secure with screw 4.
3.6
Insert cable 2 into the clips 3.
2. INTRODUCTION & SPECIFICATION
A totally dry heat, no condensation, no gas, no fumes and no smell. Reaches maximum heat output within seconds of being turned on. Highly polished
aluminium reflector for maximum heat efficiency. Adjusts horizontally through 25° while mounted. Controlled by push on/off switch or remote control,
allowing unit to be on full, half or low power. IFSH1809lR features two banks of 20 lED's for added lighting in evenings and dark areas. Ideal for indus-
trial or domestic applications. Suitable for indoor and outdoor use, if weather protected (IP24 rated).
4. OPERATION
5. MAINTENANCE
WARNING!
Ensure you read, understand and apply the safety
instructions in Section 1 before using the heater.
4.1
Ensure the heater is at least 1m from any object. The heater can be tilted
from 0° to 25°, set it to the required angle before switching the heater on.
4.2
Plug in the heater and switch it on using the ON/OFF Heat button on the base
of the heater, a blue indicator light will flash indicating that the unit is in stand
by mode. Press either the ON/OFF button on the control panel or on the
remote to turn the heater on, the blue indicator light will be on.
4.3
On models fitted with lED lights, switch on the lights by using the ON/OFF
light button on the base of the unit, a blue indicator light will flash indicating
that the unit is in stand by mode press the button again or the button on the
remote to switch on the lED's, the blue indicator light will be on.
4.4
When the heater or lights are no longer required, switch off using the
appropriate ON/OFF button(s) on the base and unplug the unit.
NOTE:
When switching off using the remote, the heater and lights will be in
stand by mode.
4.5
The heater has a built in tilt switch safety mechanism that switches off the unit
if it is tilted beyond 25° either forwards or backwards. This prevents fire in the
event of the unit being knocked over. If the unit does not turn on again when
returned to the vertical, tip it approximately 25° in the opposite direction until
you hear the internal switch operate. As the heater switches on return it to the
vertical position.
fig.1
fig.2
5.1
make sure the heater plug is disconnected from the mains supply
before any cleaning is attempted. Also allow the heater to cool
completely.
DO NOT
use water, other liquids, or harsh abrasive
cleaners to clean the heater.
DO NOT
touch the carbon fibre
element with fingers as this may damage the tube.
5.2
Clean the exterior with a soft damp cloth with some mild
detergent.
5.3
To replace the element or any of the lamps, contact your
authorised Sealey dealer.
5.4
To change the remote batteries, press down and push back the
battery cover (fig.2), remove old batteries and replace with two
new AAA batteries.
WARNING! DO NOT mix old and new batteries and dispose of
old batteries in accordance with local authority regulations.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT:
No liability is accepted for incorrect use of this product.
WARRANTY:
Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION:
For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
01284 757500
01284 703534
sales@sealey.co.uk
Sole UK Distributor, Sealey Group,
Kempson Way, Suffolk Business Park
,
Bury St. Edmunds, Suffolk,
IP32 7AR
www.sealey.co.uk
Web
Original Language Version
IFSH1809R, IFSH1809lR Issue: 3 - 29/03/10