SMD LED Extra SLiM FLooDLight
with Pir SEnSor
Model no’s:
LED112Pir, LED113Pir, LED114Pir, LED115Pir
thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT:
PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
1. SaFEty
1.1.
ELEctricaL
SaFEty
warning!
It is the user’s responsibility to read, understand and comply with the following:
warning!
THIs PRodUCT MUsT Be InsTAlled BY A QUAlIFIed eleCTRICIAn.
9
You must check all electrical equipment and appliances to ensure they are safe before using. You must inspect power supply leads
and all electrical connections for wear and damage.
9
You must ensure the risk of electric shock is minimised by the installation of appropriate safety devices. An RCCB (Residual Current
Circuit Breaker) should be incorporated in the main distribution board.
9
You must also read and understand the following instructions concerning electrical safety.
9
ensure the light is connected to an appropriate electrical on/off switch.
9
ensure the insulation on all cables and the product itself is safe before connecting to the mains power supply.
9
ensure that cables are always protected against short circuit and overload.
9
Regularly inspect power supply, leads and all electrical connections for wear and damage, especially power connections, to ensure
that none are loose.
9
ensure the voltage marked on the product is the same as the electrical power supply to be used.
8
Do not
pull power cable once installed.
8
Do not
use worn or damaged leads, or connections. Immediately replace or have repaired by a qualified Electrician.
9
Ensure the unit is correctly earthed and wired according to the following. (Installation should be undertaken by a qualified electrician)
a) Connect the green/yellow earth wire to the earth terminal ‘e’.
b) Connect the brown live wire to live terminal ‘l’.
c) Connect the blue neutral wire to the neutral terminal ‘n’.
9
After wiring, check there are no bare wires, that all wires have been correctly connected and that the wire restraint is tight.
1.2.
gEnEraL SaFEty
warning!
Turn off the mains power supply before servicing or performing any maintenance.
9
Maintain the light in good condition (Repairs must only be undertaken by a qualified electrician).
9
Replace or repair damaged parts. Use genuine parts only, non authorised parts may be dangerous and will invalidate the warranty.
9
ensure the light is installed correctly in accordance with these instructions.
9
only install the light on a vertical surface.
8
Do not
fix the light on any horizontal surface i.e. ceiling, or overhang.
9
Ideally the Installation should be away from flammable or combustible materials such as wood, cloth, paper etc.
▲
DangEr
!
Do not
direct the light into a persons eyes. The units have a very intensive light output, which if incorrectly used could
cause eye damage.
8
Do not
install the light where it is likely to be knocked or hit.
8
Do not
install in bathrooms, shower rooms, sauna or such locations.
8
Do not
install near an exhaust outlet. i.e. Boiler flue, dryer outlet, etc.
8
Do not
use the light without the front glass shield fitted.
2. introDuction
Mounted in die-cast powder coated aluminium extra slim housing with wall bracket. SMD LED technology allows ultra bright
illumination whilst still keeping costs lower than traditional halogen tubes. even spread of light across a 110° angle. Features a PIR
motion detector. supplied with power cable only and suitable for outdoor mounting.
3. SPEciFication
Model no: .........................................LED112Pir .......................... LED113Pir ........................... LED114Pir ..........................LED115Pir
Colour Temperature: ....3000K, 4000K and 6000K .... 3000K, 4000K and 6000K ..... 3000K, 4000K and 6000K ......3000k, 4000k and 6000k
IP Rating:...................................................... IP44 ......................................IP44 .......................................IP44 ..................................... IP44
led Qty: ..................................................30 sMd ................................ 75 sMd ................................. 89 sMd ..............................112 sMd
lumen output: ..........................................1700lm ................................. 4500lm .................................. 5600lm .................................8500lm
PIR Motion sensor: ........................................Yes ....................................... Yes ........................................ Yes .......................................Yes
Power: .......................................................... 20W ......................................50W .......................................70W ................................... 100W
supply: ........................................................ 230V .....................................230V ......................................230V .................................... 230V
Original Language Version
© Jack sealey limited
Refer to
instructions
led112PIR, led113PIR, led114PIR, led115PIR Issue 2(3) 23/09/19