background image

  2.   INTRODUCTION &  SPECIFICATION 

1  Power Button

2  Battery Status Bar

3  Jump Start Button

4  SOS/Jump Start LED

5  White Warning LED

6  Light/SOS Button

7  Side Light Button

8  USB (5V) Outlet

 fig.1  Front Panel

1  Charging Socket
2  Low Battery Warning
3  Side Work Light

 fig.2  Left Side Panel

 fig.3  Right Side Panel

1  Booster Outlet
 Socket
2  Side Work Light

1  Booster Lead
2  Mains (230V) Charger
3   12V Charger

 fig.4   Accessory Leads

Powered by lithium-ion technology and fully protected against reverse charging and overload. The LSTART range of start/power packs benefit 

from being compact and lightweight yet have high amperage outputs. Li-ion batteries have numerous advantages over lead acid, including a flat 

discharge curve. This ensures a greater and extended performance and holds the charge for up to 5 times longer with high energy density 

levels giving more battery power per gram. The range includes three models starting with the LSTART235 (Max. 235A), LSTART405 (Max. 405A) 

and the professional LSTART810 (Max. 810A). All units are fitted with a USB socket for powering or charging a variety of small electronic 

devices including mobile phones, MP3 players and tablet PCs. LSTART235 and LSTART405 are supplied with AC 12V 1A Charger and 

in-vehicle charger lead.

 

Model No:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LSTART235. . . . . . . . . . . . . . . . LSTART405

 

Maximum Current:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 235A. . . . . . . . . . . . . . . . . . . . . .405A

 Voltage:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12V. . . . . . . . . . . . . . . . . . . . . . .12V

 

Auxilliary Output:  . . . . . . . . . . . . . . . . . . . . . . . . . . USB 5V/2A. . . . . . . . . . . . . . . . . USB 5V/2A

 

Cable & Clamp Length:  . . . . . . . . . . . . . . . . . . . . . . . . 500mm. . . . . . . . . . . . . . . . . . . . 500mm

 

Size (L x D x H): . . . . . . . . . . . . . . . . . . . . . 192 x 135 x 45mm. . . . . . . . . . . 192 x 135 x 45mm

 Weight: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1kg. . . . . . . . . . . . . . . . . . . . . 1.3kg

 

Maximum starting Capacity:. . . . . . 3000cc 4 Cylinder (petrol). . . . . 2000cc 4 Cylinder (diesel)

 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  .  .  .  .  .  4000cc 6 Cylinder (petrol) 

    Original Language Version 

© Jack Sealey Limited

1.3.1. The

 Electricity At Work Act 1989

 requires all portable electrical appliances, if used on business premises, to be tested    

 

 

by a qualified person, using a Portable Appliance Tester (PAT), at least once a year.

1.3.2. The 

Health & Safety at Work Act 1974

 makes owners of electrical appliances responsible for the safe condition of the appliance and  

 

the safety of the appliance operator. If in any doubt about electrical safety, contact a qualified electrician.

1.3.3. 

DO

 ensure that the insulation on all cables and the product itself is safe before connecting to the mains power supply. 

1.3.4. 

DO

 ensure that cables are always protected against short circuit and overload.

1.3.5. 

DO

 regularly inspect power supply, leads, plugs for wear and damage and power connections to ensure that none is loose.

1.3.6. 

DO

 check product voltage is the same as power supply to be used and check that all fused plugs are fitted with the correct capacity    

 fuses.

LSTART235, LSTART405    Issue No: 5(SP) - 13/07/14

Summary of Contents for LSTART235

Page 1: ...hese batteries may explode and cause personal injury and damage to property DO NOT charge or boost a frozen battery DO NOT use attachments other than those recommended To do so may risk damage to the unit and other equipment and possible personal injury DO NOT pull or carry the unit by its cables and do not pull the negative and positive clamps from the battery terminals DO NOT operate in vicinity...

Page 2: ...supplied with AC 12V 1A Charger and in vehicle charger lead Model No LSTART235 LSTART405 Maximum Current 235A 405A Voltage 12V 12V Auxilliary Output USB 5V 2A USB 5V 2A Cable Clamp Length 500mm 500mm Size L x D x H 192 x 135 x 45mm 192 x 135 x 45mm Weight 1kg 1 3kg Maximum starting Capacity 3000cc 4 Cylinder petrol 2000cc 4 Cylinder diesel 4000cc 6 Cylinder petrol Original Language Version Jack Se...

Page 3: ... 3 3 above 4 3 5 If the vehicle has started successfully remove the clips from the battery as soon as possible remove negative clip first 4 3 6 If after following the above procedures the vehicle has still failed to start and the red and white LED s on the front panel are flashing alternately the battery is potentially short circuiting It MUST be replaced NOTE These boosters are capable of startin...

Page 4: ...l 1 At the end of the product s life take it to a recycling centre that handles lithium ion batteries 2 If there is no recycling centre in the area contact the local environmental agency for disposal instructions Dispose of batteries according to local authority guidelines Under the Waste Batteries and Accumulators Regulations 2009 Jack Sealey Ltd are required to inform potential purchasers of pro...

Reviews: