WARNING!

 Ensure that you read, understand and apply the safety instructions before use.

 

WARNING!

 Do NoT attempt to overload the lift. The hydraulic pump is equipped with a safety valve which will prevent an excessive   

 

load from being lifted.

4.1. 

Position the lift in a suitable area, checking that the surface on which the lift will stand is solid and flat (preferably concrete). Ensure that  

 

the adjusting screws (18) are screwed down to raise the castor wheels off the ground and thus prevent the lift moving during use.

4.2. 

Check that the lift is fully lowered, that the vice jaws are open and that the sliding plate is in position.

4.3. 

Wheel  the bike up the lead plate (37) and onto the platform so that the front of the wheel is just beyond the vice. Support bike on    

 

centre/paddock stand as applicable. 

Note:

 1. If rear wheel is to be removed bike must be positioned so that the rear wheel is over the platform aperture.

 

2. There is a choice of mounting holes for the vice to cater for various sizes of bike.

4.4. 

Clamp front wheel in vice to prevent any movement of the bike.

4.5. 

Strap the bike securely to the platform.

4.6. 

Raise the lift by pumping the lift foot pedal (11).

4.7. 

When the lift is fully raised pass the locking bar (22) through the holes in the front lifting arm (38) so that the lift cannot be inadvertently  

 

lowered.

4.8. 

When work is complete, check under the lift to ensure that there are no obstructions and that it is safe to lower the unit.

 

Remove the locking bar from the front lifting arm and then SLoWLY press the release valve pedal (10) to GENTLY lower the lift.

s

 

IMPORTANT:

 The speed of lowering is controlled by the release valve. The more the valve is opened the more rapidly the lift  

 

 

descends. Ensure the descent is slow and controlled.

4.9. 

When the lift is fully lowered, open the vice jaws and remove the bike from the lift.

  4.  OPERATING INSTRUCTIONS

5.1. 

When the lift is not in use, it must be stowed in the lowest position to minimise ram and piston corrosion. 

 

5.2. 

Keep the lift clean and wipe off any oil or grease. Lubricate all moving parts. 

5.3. 

Before each use check all parts. If any part of the lift is damaged or suspect remove lift from service and take necessary action to repair. 

 

DO NOT

 use the lift if it is believed to have been subjected to abnormal load or shock. Inspect and take appropriate action.

5.4. 

Periodically check the ram and piston for signs of corrosion. Clean exposed areas with a clean oiled cloth.

5.5. 

The hydraulic oil level is checked as follows:

 

1) Remove hydraulic unit from lift and stand upright.

 

2) Remove vented plug (fig.1.A). Correct oil level is up to plug aperture - add hydraulic oil as necessary.

❐ 

 

WARNING!

 only a good quality hydraulic oil, such as SEALEY HYDRAuLIC oIL, must be used. Do NoT use brake fluid.

s

  

IMPORTANT:

 only fully qualified personnel should attempt maintenance or repair. Contact your authorised dealer.

  5.  MAINTENANCE

  6.  DECLARATION OF CONFORMITY

IMPORTANT: NO RESPONSIBILITY IS ACCEPTED FOR INCORRECT USE OF THE LIFT.

Hydraulic products are repaired by local service agents only. We have service/repair agents in all parts of the uK. 

DO NOT return THE product to us

. Please call us on 01284 757500 to obtain the address and telephone number of your local agent. 

If the product is under guarantee please contact your dealer.

De-commissioning

Should the lift become completely unserviceable, draw off the oil into an approved container and dispose of the lift and the oil according to local 

regulations.

Declaration of Conformity 

We, the sole importer into the uK, declare that the product listed here is 

in conformity with the following standards and directives.

For Jack Sealey Ltd. Sole importer into the UK of Sealey Quality Machinery.

390kG HYDRAULIC MOTORCYCLE LIFT

Model: MC390

2006/42/EC Machinery Directive

93/68/EEC CE Marking Directive

12th November 2007

Signed by Mark Sweetman

The construction file for this product is held by the Manufacturer and may be inspected, by a national 

authority, upon request to Jack Sealey Ltd.

NOTE:

 

It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: 

No liability is accepted for incorrect use of this product. 

WARRANTY: 

Guarantee is 12 months from purchase date, proof of which will be required for any claim. 

INFORMATION: 

For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

MC390 - 3 -121107

01284 757500

01284 703534

sales@sealey.co.uk

Sole Uk Distributor

Sealey Group,

Bury St. Edmunds, Suffolk.

www.sealey.co.uk

We b

email

Reviews: