InstructIons for:
CALIBRATION RIG FOR MS070
MoDEL no:
MS070CR
thank you for purchasing a sealey product. Manufactured to a high standard this product will, if used according to these instructions
and properly maintained, give you years of trouble free performance.
1. SAFETY INSTRUCTIONS
IMPORTANT:
PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS.
USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE
DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
1.1
GENERAL SAFETY
WARNING!
Ensure Health & Safety, local authority, and general
workshop practice regulations are adhered to when using this
equipment.
Maintain the
calibration rig in good condition.
replace or repair damaged parts.
Use genuine parts only.
Non-authorised parts may be dangerous and will invalidate
the warranty.
Locate the
calibration rig in a suitable working area, keep
area clean and tidy and free from unrelated materials.
Keep the
calibration rig clean to ensure accurate
performance.
DO NOT
use outside in damp or wet weather conditions.
DO NOT
allow untrained persons to operate the
calibration rig.
DO NOT
leave the
calibration rig unattended.
WARNING!
the warnings, cautions and instructions
contained within this document cannot cover all possible
conditions and situations that may occur. It must be
understood that common sense and caution are factors
which cannot be built into this product, but must be
applied by the operator.
Original Language Version
Ms070cr Issue: 2 - 20/07/12
1.2 LASER SAFETY
the Ms070 utilises a class 2M laser that emits low
levels of visible radiation light (i.e. wavelengths between
630 and 640 nanometres) which are safe for the skin but
not inherently safe for the eyes. the class 2M emission limit is set
at the maximum level for which eye protection is normally afforded
by natural aversion responses to bright light. Accidental eye
exposure is therefore normally safe, although the natural aversion
response can be overridden by deliberately staring into the beam,
and can also be influenced by the use of alcohol or drugs.
WARNING!
Do not look or stare into the laser beam as
permanent eye damage could result.
DO NOT
direct the laser beam at any person’s (or animal’s)
eyes as eye damage could result. If the beam is obstructed by
a person during use, release the contact switch immediately.
DO NOT
use the equipment while under the influence of
alcohol, drugs or whilst on medication.
Be aware that reflections of the laser beam from mirrors or
other shiny surfaces can be as hazardous as direct eye
exposure.
2. INTRODUCTION
used to check and adjust the alignment of the lasers on Model no.
Ms070 Motorcycle Wheel Alignment tool. this unit will allow
workshops to check and adjust in-house.
© Jack sealey Limited
3. SET-UP
3.1
Rig set up:
the twin laser units as seen in fig.1 need to be
clamped either side of the calibration rig as shown in fig.2.
3.1.1 Position the left hand laser unit with the rod attached on the
left hand side of the rig and insert the rod through the hole in
the rig. slide the right hand laser unit onto the rod and up to
the other side of the rig, followed by the spring and clamp
unit.
3.1.2 Ensure that the shouldered fixing on the side of the left hand
laser from which the rod emerges passes into the hole in the
side of the rig so that both laser units lay completely flush
either side of the calibration rig.
fig.1
fig.2