background image

INsTRUCTIoNs FoR:

INVERTERS

Model Nos: 

MW80, MW125, MW155

Thank you for purchasing a sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained, 

give you years of trouble free performance.

IMPORTANT

BEFORE  USING THIS  PRODUCT,  PLEASE  READ  THE  INSTRUCTIONS  CAREFULLY.  MAKE  CAREFUL  NOTE  OF  SAFETY  INSTRUCTIONS, 

WARNINGS AND CAUTIONS. THIS PRODUCT SHOULD ONLY BE USED FOR ITS INTENDED PURPOSE. FAILURE TO DO SO MAY CAUSE DAMAGE 

AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. RETAIN THESE INSTRUCTIONS FOR FUTURE USE.

  1.  SAFETY INSTRUCTIONS

1.1.  ELECTRICAL SAFETY

  

WARNING!

 It is the responsibility of the owner and the operator to read, understand and comply with the following:

You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and any other 

connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices. A 

Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. We also recommend that a Residual Current 

device (RCd) is used. It is particularly important to use an RCd with portable products that are plugged into a supply which is not protected by 

an RCCB. If in any doubt consult a qualified electrician. You may obtain a Residual Current device by contacting your sealey dealer. 

You must also read and understand the following instructions concerning electrical safety.

1.1.1.  The 

Electricity at Work Act 1989

 requires that all portable electrical appliances, if used on business premises, are tested by a qualified  

 

electrician, using a Portable Appliance Tester (PAT), at least once a year.

1.1.2.  The 

Health & Safety at Work Act 1974

 makes owners of electrical appliances responsible for the safe condition of those appliances   

 

and the safety of the appliance operators. If in any doubt about electrical safety, contact a qualified electrician.

1.1.3.  ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. see 1.1.1. and 1.1.2.    

 

and use a Portable Appliance Tester.

1.1.4.  ensure that cables are always protected against short circuit and overload.

1.1.5.  Regularly inspect power supply cables and plugs for wear or damage and check all  

 

 

connections to ensure that none is loose.

1.1.6. 

Important:

 ensure that the voltage marked on the appliance matches the power supply 

 

to be used and that the plug is fitted with the correct fuse - see fuse rating at right.

1.1.7. 

DO NOT

 pull or carry the appliance by the power cable.

1.1.8. 

DO NOT

 pull the plug from the socket by the cable.

1.1.9. 

DO NOT

 use worn or damaged cables, plugs or connectors. Immediately have any faulty 

 

item repaired or replaced by a qualified electrician. When a Bs 1363/A UK 3 pin plug is  

 

 

damaged, cut the cable just above the plug and dispose of the plug safely. 

 

Fit a new plug according to the following instructions (UK only).

 

a)  Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

 

b) Connect the BROWN live wire to the live terminal ‘L’.

 

c)  Connect the BLUE neutral wire to the neutral terminal ‘N’.

 

d) After wiring, check that there are no bare wires, that all wires have been correctly    

 

connected, that the cable outer insulation extends beyond the cable restraint and that the restraint is tight.

 

double insulated products, which are always marked with this symbol      , are fitted with live (brown) and neutral (blue) wires only.    

 

To rewire, connect the wires as indicated above - 

DO NOT

 connect either wire to the earth terminal.

1.1.10. Products which require more than 13 amps are supplied without a plug. In this case you must contact a qualified electrician to ensure   

 

that a suitably rated supply is available. We recommend that you discuss the installation of an industrial round pin plug and socket with  

 

your electrician.

1.1.11. If an extension reel is used it should be fully unwound before connection. A reel with an RCd fitted is preferred since any appliance    

 

plugged into it will be protected. The cable core section is important and should be at least 1.5mm², but to be absolutely sure that the   

 

capacity of the reel is suitable for this product and for others which may be used in the other output sockets, we recommend the use of  

 

2.5mm² section cable.

1.1.12. 

  

WARNING!

 

Be very cautious if using a diesel generator. The generator must be stable with regard to frequency (H3),  

 

 

voltage and wave form. The output must be higher than the power (kVA) of the inverter. The diesel generator must also be self  

 

regulating. If any A.M. feature is not respected the working of the regulation card may be affected.  

 

Use of a generator without a regulator may be dangerous and will invalidate your inverter warranty.

FUSE RATING 13 AMP

Blue 

Neutral 

Wire

Yellow & Green 

Earth Wire 

Cable 

Restraint

Brown

Live 

Wire

1.2.     GENERAL SAFETY

  DANGER! Unplug the inverter from the mains power supply before connecting or disconnect cables or performing maintenance or  

  service. Direct contact with the inverter circuit is dangerous.

  

Keep the inverter and cables in good working order and condition. 

Take immediate action to repair or replace damaged parts.

  

Use genuine parts and accessories only. 

Unapproved parts may be dangerous and will invalidate the warranty.

 

 

 Keep the inverter clean for best and safest performance.

  

locate the inverter in a suitable work area. ensure that the area has adequate ventilation as welding fumes are harmful.

  

WARNING! Cable connectors must be turned fully into the quick plugs to ensure a good electrical contact. Loose connections will  

  cause overheating, rapid deterioration and loss in efficiency.

  

ensure that there is no obstruction to the flow of clean, cool air and ensure that there are no conductive dusts, corrosive vapours or humidity  

  which could enter the inverter and cause serious damage.

  

Keep the work area clean and tidy and free from unrelated materials. Also ensure that the work area has adequate lighting.

  

WARNING: Use welding head shield to protect eyes and avoid exposing skin to ultraviolet rays given off by electric arc. Wear safety  

  welding gauntlets.

  

Remove ill fitting clothing, remove ties, watches, rings and other loose jewellery and contain long hair.

  ensure that the workpiece is correctly secured before operating the inverter.

MW80, MW125,  MW155     Issue No.1    04/05/10

Original Language Version

Summary of Contents for MW80

Page 1: ...MW80 MW125 MW155 Models INSTRUCTIONS FOR INVERTERS MW80 MW125 MW155 Issue No 1 04 05 10 mw125 mw155 ...

Page 2: ...e to the live terminal L c Connect the BLUE neutral wire to the neutral terminal N d After wiring check that there are no bare wires that all wires have been correctly connected that the cable outer insulation extends beyond the cable restraint and that the restraint is tight Double insulated products which are always marked with this symbol are fitted with live brown and neutral blue wires only T...

Page 3: ... 2 description 3 specification 3 1 SPECIFICATION Model No MW80 MW125 MW155 Peak Power 80A 125A 150A Output 10 80A 10 130A 10 150A Duty Cycle 45 80A 60 125A 60 150A Electrode Capacity Ø1 6 2 5mm Ø1 6 3 2mm Ø1 6 4 0mm Max Absorbed Power 2 3kW 3 5kW 4 1kW Mains Voltage 230V 1ph 230V 1ph 230V 1ph Insulation Class F F F Protection IP21 IP21 IP21 Weight 3 7kg 5 5kg 5 5kg ARC Accessory Kit YES 6mm YES 10...

Page 4: ...e into the back of the arm with the bare wire under the plate Tighten the clamp screw 5 1 3 Slide the black rubber sleeve back over the clamp arm 5 2 Electrode Holder See fig 4 B 5 2 1 Undo the handle retaining screw Pull the handle from the head and thread the free end of the cable through it as shown Remove the pre cut section of insulation from the cable end 5 2 2 Loosen the clamp screw on the ...

Page 5: ... before striking the arc 9 1 ARC WELDING 9 1 1 Strike the electrode tip on the workpiece as if you were striking a match WARNING DO NOT hit the electrode on the workpiece as this may damage the electrode 9 1 2 As soon as the arc is struck maintain a distance from the workpiece equal to the diameter of the electrode Keep this distance as constant as possible for the duration of the weld As you adva...

Page 6: ...it may or may not be earthed for safety reasons Changing the earthing arrangements should only be authorised by a person who is competent to assess whether the changes will increase the risk of injury e g by allowing parallel welding cutting circuit return paths which may damage the earth circuits of other equipment Further guidance is given in IEC 974 13 Arc Welding Equipment Installation and Use...

Page 7: ...ection bonding the workpiece to earth may reduce emissions in some but not all instances Care should be taken to prevent the earthing of the workpiece increasing the risk of injury to others or damage to other electrical equipment Where necessary the connection of the workpiece to earth should be made by a direct connection to the workpiece but in some countries where direct connection is not perm...

Reviews: