background image

20L 3-IN-1 ASH VACUUM CLEANER 
1200W/230V

MODEL NO: 

PC200A

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these 
instructions, and properly maintained, give you years of trouble free performance.

I

MP

PO

R

RTA

TANT:

 PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE 

TH

HE

P

PR

O

ODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR

PE

ER

S

SON

NAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

1. SAFETY

1.1. ELECTRICAL 

SAFETY

WARNING!

 It is the user’s responsibility to check the following:

 

Check all electrical equipment and appliances to ensure that they are safe before using. Inspect power supply leads, plugs and    

 

all electrical connections for wear and damage. Sealey recommend that an RCD (Residual Current Device) is used with  

 

 

all electrical products. You may obtain an RCD by contacting your local Sealey Stockist. 

 

If the product is used in the course of business duties, it must be maintained in a safe condition and routinely PAT (Portable  

 

 Appliance 

Test) 

tested.

 

Electrical safety information, it is important that the following information is read and understood.

1.1.1. 

  

Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. 

1.1.2. 

  

Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.

1.1.3.   Important

: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is 

fi

 tted with the    

 

correct fuse - see fuse rating in these instructions.

  DO 

NOT

 pull or carry the appliance by the power cable.

DO NOT

 pull the plug from the socket by the cable. Remove the plug from the socket by maintaining a 

fi

 rm grip on the plug.

  DO 

NOT

 use worn or damaged cables, plugs or connectors. Ensure that any faulty item is repaired or replaced immediately by a   

 quali

fi

 ed electrician.

1.1.4. 

  

This product is 

fi

 tted with a BS1363/A 13 Amp 3 pin plug. 

 

If the cable or plug is damaged during use, switch the electricity supply and remove from use. 

 

Replace a damaged plug with a BS1363/A 13 Amp 3 pin plug. If in doubt contact a quali

fi

 ed electrician.

 

Class II products are wired with live (brown) and neutral (blue) only, and are marked with the 

 

Class II symbol;

 

A) Connect the BROWN live wire to the live terminal ‘L’.

 

B) Connect the BLUE neutral wire to the neutral terminal ‘N’.

 

C) After wiring, check that there are no bare wires and ensure that all wires have been correctly

 

    connected. 

 

Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight. 

  DO 

NOT 

connect either wire to the earth terminal. 

 

Sealey recommend that repairs are carried out by a quali

fi

 ed electrician. 

1.2. GENERAL 

SAFETY

WARNING!

 This ash vacuum cleaner is for the vacuuming of cold ashes from 

fi

 replaces, wood or coal stoves, BBQ’s and grills.

 

 

NOTE:

 Cold ash is defined as ash that has sufficiently cooled down without any pockets of hot embers.

   Rake through the ash with metal tools, to check for any hot embers prior to using the ash vacuum cleaner.

DO NOT

 use for vacuuming materials with a temperature above 40ºC.

DANGER

DO NOT

 vacuum hot or glowing ash, cigarette ends, in

fl

 ammable, explosive, corrosive or other dangerous substances.

DO NOT

 use to vacuum soot.

DO NOT

 use to vacuum the following health hazardous dusts:

 

  Class L (soft woods and solid surface material).

 

  Class M (hard woods, board materials, concrete and brick dust).

   

  Class H (asbestos and mould).

DO NOT

 operate the ash vacuum cleaner without the 

fi

 lter in place. Using the ash vacuum cleaner without the 

fi

 lter may result in   

  motor failure and will invalidate the warranty.

DO NOT

 allow children or untrained persons to operate the ash vacuum cleaner.

DO NOT

 place the attachments close to your face.

DO NOT

 point the hose end at other persons or animals.

DO NOT

 leave the ash vacuum cleaner running unattended. Turn the power supply OFF when not in use.

DO NOT

 operate the ash vacuum cleaner while under the in

fl

 uence of drugs, alcohol or intoxicating medication.

DO NOT

 use the ash vacuum cleaner in the rain or in very damp conditions.

DO NOT

 use the ash vacuum cleaner for a task it is not designed to perform.

   Disconnect the ash vacuum cleaner from the power supply before servicing, changing accessories, or performing and    

 

 maintenance.

   Use only genuine parts and accessories. Unauthorised parts and accessories may be dangerous and will invalidate  your warranty.

Recommended fuse rating

13 Amp

PC200A  Issue 1 23/11/21

Original Language Version

© Jack Sealey Limited

Refer to 

instructions

Keep in dry area 

protect from rain

Summary of Contents for PC200A

Page 1: ...oubt contact a qualified electrician Class II products are wired with live brown and neutral blue only and are marked with the Class II symbol A Connect the BROWN live wire to the live terminal L B Connect the BLUE neutral wire to the neutral terminal N C After wiring check that there are no bare wires and ensure that all wires have been correctly connected Ensure that the cable outer sheath exten...

Page 2: ...ig 2 5 1 2 Place the HEPA filter and outer mesh filter onto the motor cover and secure by turning the filter in the direction of the lock arrow indicator fig 2 NOTE There is a safety switch fitted on the motor cover which prevents the ash vacuum cleaner from operating with no filter 5 2 REMOVING THE FILTER 5 2 1 To remove the filter follow section 5 1 but in reverse 5 3 ATTACHING THE MOTOR COVER 5...

Page 3: ...tor shows red this indicates that the filter needs replacing or cleaning 7 MAINTENANCE WARNING Prior to carrying out any maintenance or cleaning isolate the ash vacuum cleaner from the electrical power source 7 1 HEPA FILTER CLEANING 7 1 1 When there is a notable reduction of suction the HEPA filter will require cleaning 7 1 2 Remove the motor cover from the tank See section 5 4 7 1 3 Remove the f...

Page 4: ...pplicable into approved containers and dispose of the product and fluids according to local regulations WEEE REGULATIONS Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment WEEE When the product is no longer required it must be disposed of in an environmentally protective way Contact your local solid waste authorit...

Reviews: