1.  SAFETY

1.1 

  ELECTRICAL SAFETY

 

‰

  

WARNING!

 It is the user’s responsibility to check the following:

 

Check all electrical equipment and appliances to ensure that they are safe before using. Inspect power supply leads, plugs and    

 

all electrical connections for wear and damage. Sealey recommend that an RCD (Residual Current Device) is used with all 

 

electrical products. You may obtain an RCD by contacting your local Sealey stockist. 

 

If the lamp is used in the course of business duties, it must be maintained in a safe condition and routinely PAT (Portable  

 

 

Appliance Test)  tested.

 

Electrical safety information, it is important that the following information is read and understood.

1.0.1.   

Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. 

1.0.2.   

Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.

1.0.3. 

  

Important

: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with the    

 

correct fuse - see fuse rating in these instructions.

 

8

   DO  NOT

 pull or carry the appliance by the power cable.

 

8

  

DO NOT

 pull the plug from the socket by the cable. Remove the plug from the socket by maintaining a firm grip on the plug.

 

8

   DO  NOT

 use worn or damaged cables, plugs or connectors. Ensure that any faulty item is repaired or replaced immediately by a   

  qualified electricia

n.

1.0.4. 

  

This product is fitted with a BS1363/A 13 Amp 3 pin plug. 

 

If the cable or plug is damaged during use, switch the electricity supply and remove from use. 

 

Replace a damaged plug with a BS1363/A 13 Amp 3 pin plug. If in doubt contact a qualified electrician.

 

Class II products are wired with live (brown) and neutral (blue) only are marked with the 

 

Class II symbol;

 

A) Connect the BROWN live wire to the live terminal ‘L’.

 

B) Connect the BLUE neutral wire to the neutral terminal ‘N’.

 

C) After wiring, check that there are no bare wires and ensure that all wires have been correctly 

 connected. 

 

Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight. 

 

8

   DO  NOT 

connect either wire to the earth terminal. 

 

Sealey recommend that repairs are carried out by a qualified electrician.

1.2 

   GENERAL SAFETY 

 

9

   Disconnect the cleaner from the power supply before servicing, changing accessories, or performing any maintenance.

 

9

   Use only genuine parts and accessories. Unauthorised parts and accessories may be dangerous and will invalidate your warranty.

 

9

  Maintain the cleaner in good condition. Use an authorised agent for servicing. Keep machine clean, but 

DO NOT 

use solvents.

 

9

   For dry vacuuming ensure the cartridge filter is locked in place before operating the cleaner.

 

8

   DO NOT

 operate the unit without the locking cartridge filter in place (except when wet vacuuming). 

Using the cleaner without a    

  cartridge filter will cause machine faults and will invalidate your warranty.

 

 

 

9

   Wear protective clothing and gloves. 

 

8

   DO  NOT

 allow children or untrained persons to operate the cleaner. 

 

8

   DO NOT

 place attachments close to your face (especially eyes, ears, etc). 

 

8

   DO NOT

 point the hose end at other persons or animals.

 

‰

   DANGER! DO NOT

 vacuum hot or glowing ash, cigarette ends, inflammable, explosive, corrosive or other dangerous substances.

 

8

   DO NOT

 operate the unit without the dust bag or optional cartridge filter (except when wet vacuuming). 

 

8

  DO NOT

 leave machine running unattended. Turn power supply OFF. 

DO NOT

 leave the vicinity until motor has come to a complete stop. 

 

8

   DO NOT

 operate the cleaner while under the influence of drugs, alcohol or impairing medication, or if you are tired. 

 

8

   DO NOT

 use the cleaner in the rain or in very damp conditions. 

 

8

   DO NOT

 use the cleaner for a task it is not designed to perform. 

 

9

   When not in use, store the cleaner in a safe, dry, childproof location.

Recommended fuse rating

13 Amp

P

C200SD.V3   Issue 4 (4,F)  08/09/20

Original Language Version

© Jack Sealey Limited

Read before 

first use

Wear 

protective

clothing 

Wear 

protective

gloves 

Wear 

eye

protection

Summary of Contents for PC200SD.V3

Page 1: ... with a BS1363 A 13 Amp 3 pin plug If in doubt contact a qualified electrician Class II products are wired with live brown and neutral blue only are marked with the Class II symbol A Connect the BROWN live wire to the live terminal L B Connect the BLUE neutral wire to the neutral terminal N C After wiring check that there are no bare wires and ensure that all wires have been correctly connected En...

Page 2: ...sure they are pushed all the way in and fix them with the self tapping screws provided fig 2 5a DO NOT overtighten 5 6 The wheel assembly mouldings are marked 1 and 2 Insert the wheel assembly mouldings into the two remaining slots in the base ensuring that the number on each moulding matches the number to be found on the base Ensure they are pushed all the way in and fix them with the self tappin...

Page 3: ...e desired nozzle fig 4 3 7 4 Ensure the switch is Off position 0 before plugging into the power supply 7 5 Press the switch to On position I fig 4 5 NOTE To vacuum large quantities of liquid from a sink or tank etc DO NOT immerse the nozzle completely in the liquid leave a gap at the top of the nozzle opening to allow an air inflow The machine is fitted with a float valve which stops the suction a...

Page 4: ... container inlet blocked Check nozzle hose container inlet for blockage Sealey Group Kempson Way Suffolk Business Park Bury St Edmunds Suffolk IP32 7AR 01284 757500 01284 703534 sales sealey co uk www sealey co uk WEEE REGULATIONS Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment WEEE When the product is no longe...