background image

INSTRUCTIONS FOR:

 

3 IN 1 VALETING MACHINE 

& VACUUM CLEANER  

MODEL No:

 PC320.V2

Thank you for purchasing a Sealey cleaner. Manufactured to a high standard this product will, if used according to these instructions and 

properly maintained, give you years of trouble free performance.

IMPORTANT

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS, AND 

CAUTIONS. USE THIS PRODUCT CORRECTLY, AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY 

CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY.

1.  SAFETY INSTRUCTIONS

1.2 . 

GENERAL SAFETY

 

Disconnect the cleaner from the power source before servicing, changing accessories, or 

  performing other maintenance.

 

Maintain the machine in good condition. Use an authorised service agent. 

 

Use only genuine accessories and parts. 

Unapproved parts or accessories can be dangerous 

  and will invalidate your warranty.

 

Keep machine clean, but 

DO NOT 

use harsh abrasives or solvents. 

 

DO NOT

 place attachments close to your face and do not point hose at other persons or animals.

 

DO NOT

 use the cleaner on hot or glowing ashes, or cigarette ends.

 

DO NOT

 use the cleaner to vacuum inflammable, explosive or corrosive substances.

 

DO NOT

 vacuum hazardous dust (this may damage your health). 

 

DO NOT

 vacuum soot, talcum power or other fine powders.

 

DO NOT

 dry vacuum without the dry filter firmly in place. 

 

DO NOT

 wet vacuum with the dry filter in place, remove the dry filter and optional dust bag, if fitted.

 

DO NOT

 leave the cleaner running unattended. Always turn off the power supply.

 

DO NOT

 clean the filter with solvents.

1.1. 

ELECTRICAL SAFETY

  

WARNING!

 It is the responsibility of the owner and the operator to read, understand and comply with the following:

You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and any other 

connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices. A 

Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. We also recommend that a Residual Current 

Device (RCD) is used. It is particularly important to use an RCD with portable products that are plugged into a supply which is not protected 

by an RCCB. If in any doubt consult a qualified electrician. You may obtain a Residual Current Device by contacting your Sealey dealer. 

You must

 also read and understand the following instructions concerning electrical safety.

1.1.1.  The 

Electricity at Work Act 1989 

requires that portable electrical appliances, if used on business premises, are tested by a qualified  

 

electrician, using a Portable Appliance Tester (PAT), at least once a year.

1.1.2.  The 

Health & Safety at Work Act 1974 

makes owners of electrical appliances responsible for the safe condition of those appliances  

 

and the safety of the appliance operators. 

If in any doubt about electrical safety, contact a qualified electrician.

1.1.3.  Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. See 1.1.1. and 1.1.2.    

 

and use a Portable Appliance Tester.

1.1.4.  Ensure that cables are always protected against short circuit and overload.

1.1.5.  Regularly inspect power supply cables and plugs for wear or damage and check all  

 

connections to ensure that none is loose.

1.1.6. 

Important:

 Ensure that the voltage marked on the appliance matches the power supply 

 

to be used and that the plug is fitted with the correct fuse - see fuse rating at right.

1.1.7. 

DO NOT

 pull or carry the appliance by the power cable.

1.1.8. 

DO NOT 

pull the plug from the socket by the cable.

1.1.9. 

DO NOT

 use worn or damaged cables, plugs or connectors. Immediately have any faulty 

 

item repaired or replaced by a qualified electrician. When a BS 1363/A UK 3 pin plug is  

 

damaged, cut the cable just above the plug and 

dispose of the plug safely. 

 

Fit a new plug according to the following instructions (UK only).

 

a)  Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

 

b)  Connect the BROWN live wire to the live terminal ‘L’.

 

c)  Connect the BLUE neutral wire to the neutral terminal ‘N’.

 

d)  After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable outer  

 

 

  insulation extends beyond the cable restraint and that the restraint is tight.

 

Double insulated products, which are always marked with this symbol      , are fitted with live (brown) and neutral (blue) wires only.    

 

To rewire, connect the wires as indicated above - 

DO NOT

 connect either wire to the earth terminal.

1.1.10.  Products which require more than 13 amps are supplied without a plug. In this case you must contact a qualified electrician to ensure  

 

that a suitably rated supply is available. We recommend that you discuss the installation of an industrial round pin plug and  

 

 

socket with your electrician.

1.1.11.  If an extension reel is used it should be fully unwound before connection. A reel with an RCD fitted is preferred since any appliance    

 

plugged into it will be protected. The cable core section is important and should be at least 1.5mm2, but to be absolutely sure that the  

 

capacity of the reel is suitable for this product and for others which may be used in the other output sockets, we recommend the use   

 

of 2.5mm² section cable.

FUSE RATING

 

13 AMP

Blue 

Neutral 

Wire

Yellow & Green 

Earth Wire 

Cable 

Restraint

Brown

Live 

Wire

Original Language Version

PC320.V2    Issue: 2 - 13/01/10

Summary of Contents for PC320.V2

Page 1: ...siness premises are tested by a qualified electrician using a Portable Appliance Tester PAT at least once a year 1 1 2 The Health Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of those appliances and the safety of the appliance operators If in any doubt about electrical safety contact a qualified electrician 1 1 3 Ensure that the insulation on all...

Page 2: ...the filter cartridge and provides a quick hygienic means of emptying the cleaner Avoid sucking up sharp or damp material DO NOT SUCK DRY OBJECTS DUST ETC WITHOUT FILTER IN PLACE 3 4 For using as valet machine remove the cartridge Fig 4 filter and fit the foam filter supplied Put the detergent tank in place IMPORTANT When the motor emits a high pitched sound turn off the machine and empty the tank ...

Page 3: ...e IMPORTANT The filter is extremely delicate when wet Avoid using direct jets of water and rough physical handling that could cause damage 6 3 Make sure that the filter element is completely dry before fitting it back on 6 4 Replace the filter element not the entire cartridge if the filter has become excessively dirtied or worn 7 fitting optional dust collection bags IMPORTANT Only use the dust ba...

Page 4: ...tainer full of light soapy water DO NOT use solvents Allow to dry before use Check the filter condition and replace if necessary THE PROBLEM THE CAUSE THE SOLUTION Unit does not start Low suction No current Power cable switch or motor faulty Tank may be full of water Check the plug and fuse Repair or replace faulty part Empty tank if full Container full Filter obstructed Outlet filter obstructed H...

Page 5: ...0192BFA Container 22 186 50125BHA Trolley 23 186 30082BOX Castor wheel 24 186 50118BHU Handle 25 186 80041BDN Switch black bipolar 25A 186 80043BOE Switch illuminated bipolar 26 186 50073BHU Motor cover upper SO 27 186 50182B8N Grip cable replaces 186 50482B8M 28 186 80299BHU Pump EP7 29 186 70120BHN Support pump front 29A 186 70121BHN Support pump rear 30 186 50078ZOX Cable grip 31 186 60300BHN E...

Page 6: ...9 186 60255BON Round brush A11 186 40023BOX Aluminium extension tube A12 186 60257BON Upholstery nozzle A13 186 95001FON Large vacuum nozzle 36mm A14 186 60281BON Multi purpose frame 36mm A15 186 60278BON Liquids adaptor A16 186 50318BHN Tube lock nut A18 186 83140BOK Dust collection bags packet of 5 A19 186 83200BOG Cartridge filter A20 VAC92 250 DL Cartridge filter A21 186 83035BHB Foam filter 0...

Reviews: