background image

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, 
and properly maintained, give you years of trouble free performance.

PC35230V | Issue 3 (I) 05/10/16

Original Language Version

© Jack Sealey Limited

InStruCtIonS For: 

VACUUM CLEANER INDUSTRIAL WET/DRY 35L 1200W/230V PLASTIC DRUM 

M CLASS FILTRATION SELF CLEANING FILTER & AUTO START

modeL no:

 PC35230V

refer to 

Instruction 

manual

1.  SAFETY

1.1.    

ELECTRICAL SAFETY

 

‰

WARNING!

 It is the user’s responsibility to check the following:

Check all electrical equipment and appliances to ensure that they are safe before using. Inspect power supply leads, plugs and   

all electrical connections for wear and damage. Sealey recommend that an rCd (residual Current device) is used with all electrical  

products. You may obtain an rCd by contacting your local Sealey dealer. 

If the vacuum is used in the course of business duties, it must be maintained in a safe condition and routinely PAt (Portable   

Appliance test) tested.

Electrical safety information. 

It is important that the following information is read and understood.

1.1.1.   

ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. 

1.1.2.   

regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.

1.1.3. 

Important

: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with the    

correct fuse - see fuse rating in these instructions.

 

8

DO NOT

 pull or carry the appliance by the power cable.

 

8

DO NOT

 pull the plug from the socket by the cable. Remove the plug from the socket by maintaining a firm grip on the plug.

 

8

DO NOT

 use worn or damaged cables, plugs or connectors. ensure that any faulty item is repaired or replaced immediately by a   

qualified electrician.

1.1.4. 

This product is fitted with a BS1363/A 13 Amp 3 pin plug. 

If the cable or plug is damaged during use, switch the electricity supply and remove from use. 

Replace a damaged plug with a BS1363/A 13 Amp 3 pin plug. If in doubt contact a qualified electrician.

Class II products are wired with live (brown) and neutral (blue) only are marked with the Class II symbol;

A) Connect the BROWN live wire to the live terminal ‘L’.

B) Connect the BLUE neutral wire to the neutral terminal ‘N’.

C) After wiring, check that there are no bare wires and ensure that all wires have been correctly connected. 

 ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight. 

DO NOT 

connect either wire to the earth terminal. 

Sealey recommend that repairs are carried out by a qualified electrician.

1.2.    

GENERAL SAFETY 

 

9

disconnect the cleaner from the power supply before servicing, changing accessories, or performing any 

maintenance.

 

9

use only genuine parts and accessories. unauthorised parts and accessories may be dangerous and will invalidate your warranty.

 

9

maintain the cleaner in good condition. use an authorised agent for servicing. Keep machine clean, but 

DO NOT

 use solvents.

 

9

  

For dry vacuuming ensure the cartridge filter is firmly in place before operating the cleaner.

 

8

DO NOT

 operate the unit without the cartridge filter in place (except when wet vacuuming). 

Using the cleaner without a cartridge   

filter may cause damage to the vacuum cleaner and will invalidate your warranty.

 

 

8

DO NOT 

use when the filter system is damaged.

 

 

9

Wear protective clothing and gloves. 

 

8

DO NOT

 allow children or untrained persons to operate the cleaner. 

 

8

DO NOT

 place attachments close to your face (especially eyes, ears, etc). 

DO NOT

 point the hose end at other persons or animals.

DANGER! DO NOT

 vacuum hot or glowing ash, cigarette ends, inflammable, explosive, corrosive or other dangerous substances.

 

8

DO NOT

 operate the unit without the dust bag or optional cartridge filter (except when wet vacuuming). 

 

8

DO NOT

 leave machine running unattended. turn power supply 

OFF

, and 

DO NOT 

leave the vicinity until motor has come to a complete stop.  

 

DO NOT

 operate the cleaner while under the influence of drugs, alcohol or impairing medication, or if you are tired. 

 

8

  

DO NOT

 use the cleaner in the rain or in very damp conditions. 

 

8

  

DO NOT

 use the cleaner for a task it is not designed to perform. 

 

9

When not in use, store the cleaner indoors in a safe, dry, childproof location.

  

WARNING! The warnings, cautions and instructions in this manual cannot cover all possible conditions and situations that  

  

may occur. It must be understood by the operator that common sense and caution are factors which cannot be built into   

  

this product, but must be applied by the operator. 

 

NOTE: This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or  

 

mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use  

 

of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and  

 

user maintenance shall not be made by children without supervision.

  

recommended fuse rating

13 Amp

Summary of Contents for PC35230V

Page 1: ...e live terminal L B Connect the BLUE neutral wire to the neutral terminal N C After wiring check that there are no bare wires and ensure that all wires have been correctly connected ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight DO NOT connect either wire to the earth terminal Sealey recommend that repairs are carried out by a qualified electr...

Page 2: ...sert wet floor 12 Adaptor 5 ASSEMbLY 5 1 ensure the electrical supply is disconnected 5 2 undo the clasps 5 3 Lift off the motor housing assembly fig 1 5 4 For dry vacuum cleaning use the locking cartridge filter supplied 5 5 For dry vacuum cleaning and containment use the vacuum bag supplied 5 6 For wet vacuum cleaning fit the supplied foam filter NOTE DO NOT operate the cleaner without a filter ...

Page 3: ...r tool 7 2 7 When you have completed vacuuming press the switch B to Off position O 7 2 8 When the bag is 3 4 full or vacuuming efficiency drops remove the bag and seal the opening with the attached plug Dispose of the bag in accordance with local regulations DO NOT re use 7 2 9 Avoid using bag for sharp or damp materials 8 WET VACUUMING WARNING Ensure you read understand and apply Section 1 Safet...

Page 4: ... a new cleaned filter over the filter basket 9 4 Lock in place as described in 7 1 2 0mm clearance 10 MAINTENANCE 10 1 ensure the machine is unplugged from the power supply 10 2 disconnect the hose from the drum container 10 3 undo the clasps and remove motor housing from the drum container 10 4 Clear out any dirt or debris from the drum container and hoses 10 5 Clean the foam filter by washing it...

Reviews: