background image

 

8

  

DO NOT

 pull or carry by cable, use cable as handle, close a door on the cable, or pull cable around sharp edges or corners.

 

9

   If the supply cord is damaged, it must be replaced by the manufacturer, a qualified service agent or similarly qualified persons in order  

  to avoid a hazard.

 

8

   DO  NOT 

handle the plug or vacuum cleaner with wet hands.

 

9

   Frequently check that the float valve positioned underneath the motor is able to move freely.

 

8

  

DO NOT 

use this vacuum cleaner with a torn filter or without the filter installed.

 

8

  

DO NOT

 allow to be used as a toy. Close attention is necessary when used by or near children.

 

‰

  

WARNING!

 To reduce the risk of injury from accidental starting, unplug power cord before changing or cleaning filter.

 

‰

  

WARNING!

 Unplug from power supply when not in use and before carrying out maintenance.

 

8

  

DO NOT

 cover the ventilation openings. 

DO NOT

 vacuum with any ventilation openings blocked; keep free of dust, lint, hair or

 

anything that may reduce air flow.

 

9

   Keep hair, loose clothing, fingers, all parts of body away from openings and moving parts.

 

9

   This machine is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of  

  experience and knowledge. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children

 

without supervision. For additional protection: It is recommended that this vacuum cleaner can be used in conjunction with residual  

 

current device (RCD) with a rated residual current of 30mA or less.

 

9

   Only use the socket outlet on the machine for purposes specified in the instructions.

 

9

   If foam or liquid escapes from the machine, switch off immediately.

 

9

   Check the float valve regularly to ensure it is moving freely and examine it for signs of damage.

 

9

   Precautions should be taken when changing attachments.

 

9

   For user servicing, the machine must be dismantled, cleaned and serviced, as far as is reasonably practicable, without causing risk to  

  the maintenance staff and others. Suitable precautions include decontamination before dismantling.

 

9

   Provision must be made for local filtered exhaust ventilation where the machine is dismantled, cleaning of the maintenance area and  

  suitable personal protection must be worn whilst carrying out these tasks.

 

9

   Perform a technical inspection at least annually, consisting of, for example, inspection of filters for damage, air tightness of the

 

machine and proper function of the control mechanism.

 

9

   Besides the operating instructions and the binding accident prevention regulations valid in the country of use, observe recognized  

  regulations for safety and proper use.

 

9

   When dust removers are used, the rate at which air is exchanged in the room must be adequate if the exhaust air from the vacuum  

  cleaner is blown into the room (please observe regulations valid in the country of use).

 

9

 

  Before starting work, the operating staff must be informed on:

 

- use of the vacuum cleaner

 

- risks associated with the material to be picked up

 

- safe disposal of the picked up material.

 

9

   Before transporting the collection tank, close all the locks. 

 

8

  

DO NOT

 tilt the cleaner if there is liquid in the collection tank.

 

8

  

DO NOT

 use a crane hook to lift the cleaner.

 

9

   For class M machines, the outside of the machine should be decontaminated and wiped clean or treated with sealant before being  

  taken out of a hazardous area. All the machine parts shall be regarded as contaminated when removed from the hazardous area and  

  appropriate action taken to prevent dust dispersal.

 

If an extension reel is used it should be fully unwound before connection. A reel with an RCD fitted is preferred since any appliance    

 

plugged into it will be protected. The cable core section is important and should be at least 1.5mm², but to be absolutely sure that the  

 

capacity of the reel is suitable for this product and for others which may be used in the other output sockets, we recommend the use  

 

of 2.5mm² section cable. If an extension reel is to be used outdoors, ensure it is marked for outdoor use.

2.  INTRODUCTION

110V M Class wet and dry vacuum cleaner with a 38 litre stainless steel drum. Removes 99.9% of hazardous dust with the exposure limit value 

of >0.1mg/m³. When the air velocity starts to fall below 20 metres per second a visual LED warning light on the top of the unit will show. Built-in 

push clean system that forces air back through the filter restoring the suction power. Uses a combination of filters and lining bags to create a 

2-stage collection to stop any hazardous dust being left in the tank or becoming airborne, it also has the option of using a foam filter for wet 

cleaning which is reusable (all consumables are included, 5 x Tank liners, 5 x dust bags and 1 x foam filter). Included accessories are antistatic 

crevice tool, antistatic round brush, multi-surface floor nozzle 12” and Power tool adaptor.

3.  SPECIFICATION

Model no .......................................................... PC380M110V

A

irflow

 ...................................................................147.6m³/hr

Consumable parts

F

oam filter (x3)

 .....................................................PC380MFF 

C

artridge filter Class M

 ........................................PC380MCF

Tank liner Class M (x5) ......................................  PC380MTL,

Dust bag class M (x5) ........................................  PC380MDB

Drum size ......................................................................... 38L

Max. vacuum pressure .................................................22Kpa

Motor power ................................................................1100W

Power tool capacity ............................................110V - 660W

Supply .....................................................................110V-16A

Vacuum accessories diameter ..................................... 35mm

Original Language Version

© Jack Sealey Limited

PC380M110V  Issue:1  08/04/21

Summary of Contents for PC380M110V

Page 1: ... none are loose 9 Ensure that the voltage marked on the appliance matches the power supply to be used 8 DO NOT pull or carry the appliance by its power supply lead 8 DO NOT pull the plug from the socket by the power cable 8 DO NOT use worn or damaged cables plugs or connectors Immediately have any faulty item repaired or replaced by a qualified electrician 9 Ensure the unit is correctly earthed vi...

Page 2: ...t prevention regulations valid in the country of use observe recognized regulations for safety and proper use 9 When dust removers are used the rate at which air is exchanged in the room must be adequate if the exhaust air from the vacuum cleaner is blown into the room please observe regulations valid in the country of use 9 Before starting work the operating staff must be informed on use of the v...

Page 3: ...sing on the base Insert a washer onto the axle followed by the rear wheel and another washer Insert the wheel retaining pin into the hole on the end of the axle to lock into place Push fit the hub cap onto the wheel Repeat the same steps on the other end of the axle Fig 3 5 5 To position the hose storage rack insert one end into the channel on the side of the power head making sure it is secured i...

Page 4: ...rrect suction across different floor surfaces and applications 5 15 2 To remove the floor nozzle attachments turn the floor tool holder upside down 5 15 3 Using a flathead screwdriver or other suitable tool locate the holding clips on each outer edge 5 15 4 Insert a flat edged object directly next to the holding clip between the insert and the floor tool holder Pry the attachment up from underneat...

Page 5: ... of the suction hose nozzle into the channel located within the filter cleaner button 6 4 4 Move the on off switch to the I position 6 4 5 Turn the power regulator to the MAX position 6 4 6 Press the filter cleaning button down and hold it down for 3 4 seconds Fig 16 6 4 7 Repeat the process two more times 6 5 WET AND DRY VACUUMING OPERATION WARNING ENSURE YOU READ UNDERSTAND AND APPLY SECTION ENT...

Page 6: ...3 When this happens switch the vacuum cleaner off immediately and empty the container 7 MAINTENANCE e WARNING REMOVE THE POWER CABLE FROM THE POWER SUPPLY BEFORE CARRYING OUT ANY MAINTENANCE WARNING ALWAYS USE A P2 RESPIRATOR WHEN PERFORMING ANY MAINTENANCE AND OR REMOVING THE CARTRIDGE FILTER AFTER VACUUMING HAZARDOUS DUSTS 7 1 Keep all safety devices air vents and the motor housing free of dirt ...

Page 7: ...nd fuse Functional fault in the mains cable switch or motor Have damaged part checked by qualified personnel or contact Sealey stockist Dust is escaping from the motor cover The cartridge filter is missing or damaged Fit cartridge filter or replace it Foam filter accidentally fitted when dry vacuuming Replace foam filter with the cartridge filter Power tool take off socket does not work Power tool...

Reviews: