INSTRUCTIONS FOR:
VACUUM CLEANER HAND-HELD
MODEL No:
PC700
1. SAFETY INSTRUCTIONS
1.1. GENERAL
Keep the
PC700 clean and in good condition.
Replace or repair damaged parts.
Use recommended parts only. Unauthorised parts may be dangerous and will invalidate the
warranty.
Keep children and non-essential persons away from the work area.
DO NOT
leave the PC700 operating unattended.
DO NOT
use the PC700 for a task it is not designed for.
DO NOT
operate the PC700 when you are tired or under the influence of alcohol, drugs or intoxicating medication.
DO NOT
operate the PC700 if any parts are missing or damaged, as this may cause failure and/or personal injury.
WARNING!
Sparks inside motor can ignite flammable vapours or dust. To avoid fire or explosion do not vacuum, or use near,
flammable or combustible liquids or gases.
DO NOT
vacuum anything that is burning or smoking such as cigarettes, matches or hot ashes.
DO NOT
vacuum toxic materials to avoid health hazards from vapours or dusts.
Keep the PC700 and all accessories where they will not be subjected to heat or flame. To avoid injury, shock, or fire, never use a
damaged vacuum, cleaner or power cable.
DO NOT
put any object into openings.
DO NOT
use with any opening blocked.
Keep free of dust, lint, hair, and anything that may reduce air flow. Keep hair, loose clothing, fingers away from openings and
moving parts.
DO NOT
use without filter in place.
When not in use disconnect from supply and store in a safe, dry, childproof location.
Blue
Neutral
Wire
Thank you for purchasing a Sealey Product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained, give you
years of trouble free performance.
IMPORTANT:
PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS
AND CAUTIONS. USE THIS PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE
INSTRUCTIONS FOR FUTURE USE.
FUSE RATING
THIS PRODUCT MUST BE
FITTED WITH A
13 AMP FUSE
Original Language Version
PC700 Issue: 2 - 22/10/09
Yellow & Green
Earth Wire
Cable
Restraint
Brown
Live
Wire
1.2
ELECTRICAL SAFETY.
WARNING! It is the user’s responsibility to read, understand and comply with the following:
You must check all electrical equipment and appliances to ensure they are safe before using. You must inspect power supply leads,
plugs and all electrical connections for wear and damage. You must ensure the risk of electric shock is minimised by the installation of
appropriate safety devices. An RCCB (Residual Current Circuit Breaker) should be incorporated in the main distribution board. We also
recommend that an RCD (Residual Current Device) is used with all electrical products. It is particularly important to use an RCD with
portable products that are plugged into an electrical supply not protected by an RCCB. If in doubt consult a qualified electrician. You
may obtain a Residual Current Device by contacting your Sealey dealer.
You must
also read and understand the following instructions
concerning electrical safety.
1.2.1
The
Electricity At Work Act 1989
requires all portable electrical appliances, if used on business premises, to be tested by a
qualified electrician, using a Portable Appliance Tester (PAT), at least once a year.
1.2.2
The
Health & Safety at Work Act 1974
makes owners of electrical appliances responsible for the safe condition of the
appliance and the safety of the appliance operator.
If in doubt about electrical safety, contact a qualified electrician.
1.2.3
Ensure the insulation on all cables and the product itself is safe before connecting to the mains power supply. See 1.1.1. &
1.1.2. above and use a Portable Appliance Tester (PAT).
1.2.4
Ensure that cables are always protected against short circuit and overload.
1.2.5
Regularly inspect power supply, leads, plugs for wear and damage and power connections to ensure that none is loose.
1.2.6
Important:
Ensure the voltage marked on the product is the same as the electrical power supply
to be used, and check that plugs are fitted with the correct fuse.
See fuse rating right.
1.2.7
DO NOT
pull or carry the powered appliance by its power supply lead.
1.2.8
DO NOT
pull power plugs from sockets by the power cable.
1.2.9
DO NOT
use worn or damage leads, plugs or connections. Immediately replace or have
repaired by a qualified electrician. A U.K. 3 pin plug with ASTA/BS approval is fitted. In case of
damage, cut off and fit a new plug according to the following instructions (discard old plug
safely).
(UK only - see diagram at right).
Ensure the unit is correctly earthed via a three-pin plug.
a) Connect the GREEN/YELLoW earth wire to the earth terminal ‘E’.
b) Connect the BRoWN live wire to live terminal ‘L’.
c) Connect the BLUE neutral wire to the neutral terminal ‘N’.
d) After wiring, check that there are no bare wires, that all wires have been correctly
connected, that the cable outer insulation extends beyond the cable restraint and that the restraint is tight.
Double insulated products are fitted with live (BROWN) and neutral (BLUE) wires only. Double insulated products are always
marked with this symbol .
To re-wire, connect the brown & blue wires as indicated above.
Do NoT
connect the
brown or blue to the earth terminal.
1.2.10
Cable extension reels
. When a cable extension reel is used it should be fully unwound before connection. A cable reel with
an RCD fitted is recommended since any product which is plugged into the cable reel will be protected. The section of the
cores of the cable is important and should be at least 1.5mm², but to be absolutely sure that the capacity of the cable reel is
suitable for this product and for others that may be used in the other output sockets, we recommend the use of 2.5mm²
section cable.