7.1.4   Fit item 38A the mid height wall channel to the panel and position it by the pre-punched holes and 10mm   

 

long self tapping screws. Note this channel is fitted with the flat face uppermost, ie. nearest the “top”.

7.1.5  With self tapping screws fix items 20B and 20C to top and bottom edges.

© Jack Sealey Limited

GSS150819SD    Issue: 1 - 20/08/12

Original Language Version

Summary of Contents for Power Products GSS150819SD

Page 1: ...ere is adequate lighting Keep children and unauthorised persons away from the working area DO NOT use the shed for any purpose other than that for which it is designed Use appropriate safety clothing including eye protection Note The assembly of this product will require assistance 1 SAFETY instructions 2 INTRODUCTION Before commencing the assembly we recommend that you read the instructions thoro...

Page 2: ...b 100mm bigger than the base dimensions of your shed This will allow for a 50mm edge around your shed We recommend that you slope the 50mm edges downward by 10mm so that rain water will drain away from your shed 5 contents Check contents Lay out all components with the part numbers facing upwards and check off against the parts lists on the next four pages In the unlikely event of a missing compon...

Page 3: ...sue 1 20 08 12 Jack Sealey Limited Original Language Version sheet 1980 x 770 sheet 1980 x 770 sheet 1900 1980 x 770 sheet 80 160 x 770 sheet 855 x 770 sheet 1900 x 770 sheet 1900 x 770 sheet 1780 x 720 channel 1508 ...

Page 4: ...GSS150819SD Issue 1 20 08 12 Jack Sealey Limited Original Language Version ...

Page 5: ...GSS150819SD Issue 1 20 08 12 Jack Sealey Limited Original Language Version Ø4 x 10mm Rivet Ø3 x 10mm Rivet Pad shoot bolt Part No 70 Keeper Part No 71 Mid height wall bracket Part No 72 ...

Page 6: ...ealey Limited Original Language Version 5 1 Please note some component descriptions may differ in manual text to listings always use pictures from listings to double check component identity ie M8 fixings may be supplied in lieu of 5 16 ...

Page 7: ...6 parts diagram GSS150819SD Issue 1 20 08 12 Jack Sealey Limited Original Language Version ...

Page 8: ... using nylon cable ties or similar safe method 7 1 2 Place panel 1A and 1L on your work table and join them together with the 10mm long self tapping screws See the pre punched holes and both diagrams 7 1 3 Fit top and bottom channels 20B and 20C to panels by firstly sliding and finally tapping into place as indicated by arrows in the diagrams Note that the smaller flange on the channels should alw...

Page 9: ...he pre punched holes and 10mm long self tapping screws Note this channel is fitted with the flat face uppermost ie nearest the top 7 1 5 With self tapping screws fix items 20B and 20C to top and bottom edges Jack Sealey Limited GSS150819SD Issue 1 20 08 12 Original Language Version ...

Page 10: ... the top face in both diagrams 7 2 3 Fit item 32D the mid height wall channel to the panel and position it by the pre punched holes and 10mm long self tapping screws Note this channel is fitted with the flat face uppermost ie nearest the top 7 2 4 With self tapping screws fix item 21B to bottom edge but do not screw fix item 21A to top edge at this stage see places marked with asterisk 7 2 ASSEMBL...

Page 11: ... screws See the pre punched holes and both diagrams 7 3 2 Fit top and bottom channels 20B and 20C to panels by firstly sliding and finally tapping into place Note that the smaller flange on the channels should always be adjacent to the outside face of the panel The outside face is the diagram Fix both with 10mm long self tapping screws except for positions marked with asterisk which are not fixed ...

Page 12: ...nnel to the panel and position it by the pre punched holes and 10mm long self tapping screws Note this channel is fitted with the flat face uppermost ie nearest the top Jack Sealey Limited Original Language Version GSS150819SD Issue 1 20 08 12 ...

Page 13: ... bottom channels item 20A to panels by firstly sliding and finally tapping into place as previously explained in 7 1 3 Note that the smaller flange on the channels should always be adjacent to the outside face of the panel The outside face is the top face in both diagrams 7 4 ASSEMBLE THE ROOF PANEL GSS150819SD Issue 1 20 08 12 Jack Sealey Limited Original Language Version ...

Page 14: ... 4 3 Fit item 50 angles to each edge refer to diagram this page for flange orientation Fix with 10mm long self tapping screws GSS150819SD Issue 1 20 08 12 Jack Sealey Limited Original Language Version 50 ...

Page 15: ...DE AND FRONT PANELS TOGETHER 7 5 1 Attach the side wall 2E to the rear wall 1A 1L then the front wall 9A 9S Fix all walls with the 10mm long self tapping screws GSS150819SD Issue 1 20 08 12 Jack Sealey Limited Original Language Version ...

Page 16: ...door mullion sections are fixed with 16mm long self tapping screws Do not fix self tapping screws marked in enlarged ballooned views at this stage FIX DOOR MULLION SECTIONS WITH SIX 16mm LONG SELF TAPPING SCREWS GSS150819SD Issue 1 20 08 12 Jack Sealey Limited Original Language Version ...

Page 17: ... fix with 16mm long self tapping screws Fix the channel item 21H with 16mm long self tapping screws 7 6 3 Slide and tap on top channel item 21J but do not screw fix at this stage Jack Sealey Limited GSS150819SD Issue 1 20 08 12 Original Language Version ...

Page 18: ... pre punched holes with 4mm diameter rivets Check action of door before crimping rivets 7 7 2 Fit the shoot bolt item 70 and the bolt keeper item 71 and fix with 10mm long self tapping screws or 4mm diameter rivets fitting method A or B Jack Sealey Limited GSS150819SD Issue 1 20 08 12 Original Language Version ...

Page 19: ...ab position the 6 anchor steel angles M8 machine screw fix to internal compartment This will require spotting and drilling 8mm diameter holes through to shed panels Spot through holes to plinth slab remove anchor angles and masonry drill slab for anchor bolts Please note anchor bolts and M8 machine screws are supplied see FITTINGS PACK 7 8 3 Insert anchor bolts re fit steel angles and anchor shed ...

Page 20: ...latest catalogue and promotions call us on 01284 757525 and leave your full name and address including postcode 01284 757500 01284 703534 sales sealey co uk Sole UK Distributor Sealey Group Kempson Way Suffolk Business Park Bury St Edmunds Suffolk IP32 7AR www sealey co uk Web email 7 9 SHED RIGIDITY AND USER SAFETY 7 9 1 For shed rigidity self tapping screw fix the 2 mid height wall brace bracket...

Reviews:

Related manuals for Power Products GSS150819SD