background image

INSTRUCTIONS FOR

PLASMA INVERTERS

PP25.V2

PP25PLUS.V2

MODEL No:

Original Language Version

PP25.V2, PP25PLUS.V2    Issue: 6 - 17/01/11

Summary of Contents for PP25.V2

Page 1: ...INSTRUCTIONS FOR PLASMA INVERTERS PP25 V2 PP25PLUS V2 MODEL No Original Language Version PP25 V2 PP25PLUS V2 Issue 6 17 01 11 ...

Page 2: ...with this symbol are fitted with live brown and neutral blue wires only To rewire connect the wires as indicated above DO NOT connect either wire to the earth terminal 2 1 10 Products which require more than 13 amps are supplied without a plug In this case you must contact a qualified electrician to ensure that a suitably rated supply is available We recommend that you discuss the installation of ...

Page 3: ...al or uncontrolled switching on of the torch may be dangerous and will wear the nozzle Keep unauthorised persons away from the work area Any persons working within the area must wear the same protective items as the operator DO NOT use cables and torch if the insulation is worn or connections are loose DO NOT attempt to fit any unauthorised torch or other component to the plasma cutting unit DO NO...

Page 4: ...st up to the required pressure 5 5 2 Push the pressure regulator knob downwards to lock it 5 6 Torch control When the machine is turned on the green indicator light fig 2 7 fig 3 6 will show that the torch is in Stand By mode 5 6 1 When the torch button is pressed the machine is activated and a yellow LED will illuminate fig 2 5 fig 3 3 indicating the presence of the pilot arc As a safety feature ...

Page 5: ...tand and apply Section 2 safety instructions and that you have familiarised yourself with the controls Ensure that the machine is disconnected from the power supply before moving or changing accessories 6 1 Set up 6 1 1 PP25 Ensure that the compressed air is connected correctly to the machine see Section 4 6 1 2 Check that the earth cable is correctly clamped to the workpiece or work bench see 5 2...

Page 6: ...tion when the equipment is used closer than 30m to the receiving antenna In special cases when highly susceptible apparatus is being used in close proximity additional mitigation measures may have to be employed in order to reduce the electromagnetic emissions At the same time there could occur some potential difficulties in having electromagnetic compatibility in a non industrial environment e g ...

Page 7: ...sition e g ship s hull or building steelwork a connection bonding the workpiece to earth may reduce emissions in some but not all instances Care should be taken to prevent the earthing of the workpiece increasing the risk of injury to others or damage to other electrical equipment Where necessary the connection of the workpiece to earth should be made by a direct connection to the workpiece but in...