WARNING!

 

 Never allow the red and black clamps to  

 

touch each other or a common conductor.

4.1.8   When engine is running, always disconnect the starter in the  

 

following order:

 

1.

  Disconnect the mounting socket from the starter (starter off). 

 

2.

  Disconnect the black (negative) clamp from the vehicle.

 

3.

  Disconnect the red (positive) clamp from the vehicle.

 

4. 

return the clamps to their housing. 

 

NOTE! Recharge the starter as soon as possible.

4.2   Using the starter as a 12V power supply.

4.2.1  fold back the protective rubber plug from the accessory  

 

socket (fig.4-8).

4.2.2  Insert the accessory plug of the appliance to be powered into the  

 

socket.

4.2.3  Incase of overload the re-settable safety switch will trip. (fig.4-7)  

 

Investigate and remedy the cause  of the overload before  

 

pushing the reset button.

4.3 

Recharging the starter.

 

IMPORTANT! To protect the battery and lengthen its  

 

working life, charge it for 12 hours before using it for the  

 

first time, then after every time it is used, and in any case, at  

 

least every three months.

4.3.1  recharge the unit using the 230V Ac  power adaptor supplied.  

 

see fig.5. We recommend keeping the batteries fully charged at  

 

all times. A low charge level could shorten the life of the battery.  

 

Bear in mind that the time required to recharge the battery will  

 

depend on the number of times it has been used.

 

WARNING:  Use the supplied charger only and exclusively to  

 

charge the starter.

4.3.2  Insert the charger mains plug (see fig.5) into the mains supply.

4.3.3  Insert the charger output plug (see fig.5) into the charging socket on  

 

the control panel. see fig.4-6.

4.34  the charge level LEDs (fig.4-4) will light up in succession to indicate  

 

that the unit is being charged.

4.3.5  check the battery charge level by pressing the 'tEst' button  

 

(fig.4-5). the 3 digit display (fig.4-3) indicates the battery voltage  

 

and the bank of 6 bar type LEDs below the display indicates the  

 

charge level (fig.4-4). the 3 digit display will show the 12 volt  

 

reading first. repeated presses of the test button will toggle the  

 

display between the 12 and 24 volt readings, indicated by the  

 

two single leds at the left hand side of the test button.(fig.4-5).

4.3.6  When 'EnD' is shown on the display the charging process is  

 

complete. now unplug the charger from the unit and the mains plug  

 

from the mains supply.

notE: the starter has a device for monitoring the charge status of the  

 

batteries. When charging is complete the charger automatically  

 

resets itself and can therefore  remain connected for as long as  

 

desired. 

4.3.7  the charging system is electronically controlled. the factory  

 

settings for the electronics board are suitable for recharging the  

 

AGM lead acid batteries contained by the starter.  

When the  

 

starters internal batteries have come to the end of their  

 

working life they should be replaced with batteries of the same  

 

type and specification.

fig.4

fig.5

 

Environmental Protection

 

recycle unwanted materials instead of disposing of them as  

 

waste. All tools, accessories and packaging should be sorted,  

 

taken to a recycle centre and disposed of in a manner which is  

 

compatible with the environment. When the product is no  

 

longer required, it must be disposed of in an environmentally  

 

protective way. contact your local authority for recycling  

 

information.

 

Battery Removal

 

At the end of its working life the batteries should be removed  

 

from the unit by a qualified electrician and be 

disposed  

 

according to local authority guidelines.

 

WArnInG: Do not dispose of by fire. this could result in an  

 

explosion. 

 

under the Waste Batteries and Accumulators regulations  

 

2009, Jack sealey Ltd are required to inform potential  

 

purchasers of products containing batteries (as defined within  

 

these regulations), that they are registered with Valpak’s  

 

registered compliance scheme. Jack sealey Ltd’s Batteries  

 

Producer registration number (BPrn) is BPrn00705.   

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: 

no liability is accepted for incorrect use of this product. 

WARRANTY: 

Guarantee is 12 months from purchase date, proof of which will be required for any claim. 

INFORMATION:

 for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

sales@sealey.co.uk

Sole UK Distributor, Sealey Group, 

Kempson Way, suffolk Business Park

Bury st. Edmunds, suffolk,

IP32 7Ar

www.sealey.co.uk

Web

email

Original Language Version

Parts support is available for this product. To obtain a parts listing and/or diagram, please log on to 

www.sealey.co.uk, email sales@sealey.co.uk or phone 01284 757500.

PWrstArt6000    Issue: 2 - 16/05/11

Reviews: