2. intRoduction
composite case with integral battery clamp storage and carry handle. suitable for starting 12V vehicles with 8 cylinder petrol engines up to
6ltr and 8 cylinder diesel engines up to 4.8ltr. suitable for starting 24V vehicles with 6 cylinder petrol engines up to 3.5ltr and 6 cylinder diesel
engines up to 3ltr. front panel displays internal or external battery charge levels and includes an integral led work light. Audible reverse
polarity warning. mains charger with automatic power cut-off prevents damage to battery whilst charging. inbuilt mosfet circuit protection.
fitted with two 12V power sockets that will accept any 12V device with a vehicle accessory socket plug. supplied with mains charger.
3. specification
model no ...................................................................rs105B
cold cranking Amps ............................12V/24V - 590A/290A
P
eak Amps .......................................12V/24V - 2400A/1400A
Voltage ..................................................................... 12V/24V
Auxiliary output ............................................................2x12V
cable/clamp length ........................................................ 0.7m
Weight .........................................................................14.5Kg
4. opeRation
4.1.
jump staRting
4.1.1.
ensure both the ignition of vehicle to be started and the jumpstarter main power switch is switched
off before any connections are
made to the battery.
4.1.2.
connect the red (+) alligator clamp of the jumpstarter to the red (+) positive battery terminal of the
vehicle.
4.1.3.
connect the BlAcK(-) alligator clamp of the jumpstarter to a non-moving metal part of the engine or chassis (avoid connecting to fuel
lines).
4.1.4.
switch the Jump start main switch to on position – either 12V or 24V selection depending on vehicle system required. listen for
audible beep indicating an accidental reversed polarity – the red led light within the display will illuminate solidly, and a continuous
audible tone will be heard. if beeping is heard, switch off main power switch, disconnect then reconnect clamps in the above order
ensuring polarity is correct
4.1.5.
once Jump starter main power switch is on (12V or 24V setting), leave for approximately 30 seconds.
4.1.6.
With the jumpstarter still connected and switched on, turn the vehicle ignition and crank the engine.
8
do not
crank the engine for any more than 5 seconds at a time.
4.1.7.
if the engine fails to start, wait for at least 2 minutes before trying again to avoid overloading the unit.
4.1.8.
once the engine is running, switch the Jumpstart power switch to the off position. disconnect the BlAcK(-) negative clamp from the
vehicle first, and return the cable to its storage position on the jumpstart unit.
4.1.9.
Disconnect the RED (+) Positive clamp last, and return the cable to its storage position on the
jumpstart unit. As soon as possible,
connect the Jumpstarter to the supplied 230V Ac charger and recharge the unit to maintain battery life.
4.2.
LED MULTI-FUCTION DISPLAY fig1/fig3.
the led Battery display on the front panel shows several important pieces of information
4.2.1.
With Jump start main switch in on position (12V or 24V setting), pressing display button will show internal Battery capacity. use this
to check if recharging is required.
4.2.2.
flashing red led indicator light when recharging is underway (to see battery bars press display button -
display will go out after a few
seconds but red led light will stay lit).
4.2.3.
Red indicator light signifies fully charged (a press of the display button will also illuminate
battery bar display).
4.2.4.
Reverse Polarity – the red LED at the top of the display panel will solidly illuminate. Also a continuous alert tone will be heard.
reverse polarity testing is only available when the Jump start main power switch is in the on position (12V or 24V setting). if an
accidental reverse polarity is made, the inbuilt mosfet protection system will prevent any damage to both the Jump start unit and the
connected vehicle battery.
4.2.5.
low Voltage alert – When main Jump start switch is in the on position (either 12V or 24V setting), a single beep will be heard every 25
seconds when recharging is required together with the red led indicator at the top of the battery display flashing, or approximately
60% remaining charge. When pressing the led display button during these alerts, the remaining bars will flash on the display.
fig.1
rs105B | issue 1 18/01/18
Original Language Version
© Jack sealey limited