  Ensure that the unit is fully charged before storage.

1.3 

ELECTRiCAL SAFETY (with respect to mains chargers)

  

WARninG!

 It is the user’s responsibility to check the following:

 

You must

 check the AC adaptor to ensure that it is safe before using. 

You must

 inspect the power supply lead, plugs and all 

 

electrical connections for wear and damage. 

You must

 ensure the risk of electric shock is minimised by the installation of  appropriate  

 

safety devices. An RCCB (Residual Current Circuit Breaker) should be incorporated in the main distribution board. We recommend that  

 

an RCD (Residual Current Device) is used with all electrical products. It is particularly important to use  an RCD with portable products  

 

that plug into an electrical supply not protected by an RCCB. If in doubt consult a qualified electrician. You can obtain a Residual  

 

 

Current Device through your Sealey dealer. 

You must

 read and understand instructions concerning electrical safety.

1.3.1  The 

Electricity At Work Act 1989 

requires all portable electrical appliances, if used on business premises, to be tested by a qualified  

 

person, using a Portable Appliance Tester (PAT), at least once a year.

1.3.2  The 

Health & Safety at Work Act 1974

 makes owners of electrical appliances responsible for the safe condition of the appliance and  

 

the safety of the appliance operator. If in any doubt about electrical safety, contact a qualified electrician.

1.3.3 

DO

 ensure that the insulation on all cables and the product itself is safe before connecting to the mains power supply. 

1.3.4 

DO

 ensure that cables are always protected against short circuit and overload.

1.3.5 

DO

 regularly inspect power supply, leads, plugs for wear and damage and power connections to ensure that none is loose.

1.3.6 

DO

 check product voltage is the same as power supply to be used.

1.4  

COMPRESSOR SAFETY (RS122 OnLY)

 

Keep children and non essential persons away from the inflation area.

 

WARninG! 

This compressor is capable of producing a high pressure (100psi). 

DO nOT

 inflate any item beyond its maximum capacity.

 

DO nOT

 direct inflation hose connector head at yourself, others or animals.

 

DO nOT

 leave the compressor operating unattended. Always monitor the inflation pressure gauge.

 

DO nOT

 carry by the hose, or yank the hose from an inflation valve.

 

DO nOT

 pull the power cable from the cigarette lighter socket by the power lead.

 

DO nOT

 get the compressor wet or use in the rain.

 

DO nOT

 use the compressor for a task it was not designed to perform.

 

DO nOT

 operate the compressor when you are tired, under the influence of alcohol, drugs or intoxicating medication.

 

DO nOT

 operate the compressor if any parts are missing or the generator is damaged as this may cause failure and/or possible 

 

personal injury.

nOTE:

 The pressure gauge is not a calibrated instrument. We recommend use of an approved dial/pressure gauge for a definitive reading.

  2.   inTRODUCTiOn AnD SPECiFiCATiOn

2.1 

introduction

 

Composite case with battery clip storage lugs and carry handle. Easy read, colour coded analogue gauge measures battery 

 

condition and charge indicator. Test cycle button gives true battery indication. 230Volt charger with automatic power cut-off prevents  

 

damage to battery whilst charging from the mains. Fitted with 12Volt power socket that will accept any 12Volt device with a cigarette  

 

lighter type plug. Supplied with mains charger and double plug adaptor for in-car charging. 

 

RS122 has Integral air compressor with pressure gauge for topping/pumping up tyres. 

2.2 

Specification

 

Models 

RS121 

RS122 

RS125

 

Cold Cranking amps ...................................400A .................................................. 400A .......................... 12V - 1200A  / 24V -   600A

 

Peak Amps .................................................900A .................................................. 900A .......................... 12V - 3000A  / 24V - 1500A

 

Voltage ......................................................... 12V .................................................... 12V ..................................12V or 24V Switchable

 

Auxiliary Output ........................................... 12V .................................................... 12V ................................................................ 12V

 

Cable and Clamp Length ............................1mtr. ...................................................1mtr. ...............................................................1mtr.

 

Weight .........................................................10kg ................................................... 11kg ...............................................................15kg

 

Compressor ................................................... No ..............................Yes / Max. 100psi ..................................................................No

RS121

RS122

RS125

RS125 Charging Socket

Fig.1

Original Language Version

RS121, RS122, RS125    Issue: 3 - 08/04/10