b) check belt tension. A force of 3kg applied at the belt mid-point should give a deflection of approx. 10mm (fig.6). If adjustment is  

 

  required remember to maintain the alignment of the two pulleys (fig.6). Adjust by repositioning motor.

 

c) check all tube fittings and electrical connections.

 

d) Inspect pressure tank inside and out for damage or corrosion.

5.7.   Scheduled maintenance table

Maintenance 

Operations

Weekly

3 Monthly

Monthly

500 hrs.

1000 hrs.

Drain condensation

check oil level

clean intake filter

check belt tension

check condition of belt 

and pulleys

check tube fittings and 

electrical connections

replace oil

Internal & external 

inspection of tank

General cleaning of 

compressor

replace air filter

check tank for internal  

corrosion

check for oil leaks

Fault

Cause

remedy

Pressure drop in the tank

Air leaks at connections

run compressor to max. pressure, switch off.                   

Brush soap solution over connections and look for 

bubbles. tighten connections showing leaks. 

If problem persists contact Authorised service Agent.

compressor noisy with metallic knock

compressor speed fluctuates

compressor does not reach max. pressure

compressor does not stop at max. pressure

compressor stops and does not restart

compressor stops and does not restart

Pressure switch valve leaks when compressor is idle

Bearing or piston damage

Belt slipping

filter clogged

Head gasket or valve fault

Pressure switch fault

Motor failure

overload cut-out operated - motor overheating

non-return valve seal defective

contact Authorised service Agent.

Adjust belt. see para. 5.6.b.

replace filter element.

contact Authorised service Agent.

contact Authorised service Agent.

contact Authorised service Agent.

Press the button ‘D’ to restart (fig.5).

Empty the air tank, remove the non-return valve cap 

‘A’ (fig.7) and clean and, if necessary, 

replace the seal ‘B’. 

6.  trOUBle SHOOtinG

5.8. 

recommended oils

 

recommended oil for compressors, suitable for  

 

room temperatures ranging from +5°c to +25°c:

 

sEALEY cPo or equivalent sAE 40 compressor oil.

 

room temperatures below +5°c: 

 

sAE 20 compressor oil.

 

Approximate oil capacity: 0.45 litres.

AliGnMent

fig. 6

A

B

fig. 7

NOTE:

 It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

iMPOrtAnt: 

no liability is accepted for incorrect use of this product. 

WArrAntY: 

Guarantee is 12 months from purchase date, proof of which will be required for any claim. 

inFOrMAtiOn:

 for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

sales@sealey.co.uk

Sole UK Distributor, Sealey Group, 

Kempson Way, suffolk Business Park

Bury st. Edmunds, suffolk,

IP32 7Ar

www.sealey.co.uk

Web

email

Original Language Version

sA1050/3, sA1010/3, sA1015/3.V2, sA1020/3.V2    Issue: 2 - 21/10/09

Summary of Contents for SA1050/3

Page 1: ...r must not include any other socket which could be used for another appliance The distance of the socket from the mains distribution point must not exceed 5 metres An extension lead must not be used 1 1 11 Note Under certain conditions the compressor will draw more than 13 amps Consequently we recommend a 30 amp supply and suggest that a direct round pin plug socket is installed by a qualified ele...

Page 2: ...800 1800 13 6 13 6 9 6 9 6 9 9 9 9 9 3 9 3 50 100 145 10 145 10 79 79 2 1 Specifications 2 2 Weights Dimensions fig 1 SA1015 3 V2 3 230 1 13 K9 1800 14 10 2 10 6 9 9 150 145 10 79 SA1020 3 V2 3 230 1 13 K9 1800 14 10 2 10 6 9 9 200 145 10 79 Model Weight kg Dimensions Length x Width x Height mm SA1050 3 SA1010 3 63 70 805 x 400 x 740 1095 x 420 x 830 SA1015 3 V2 79 1280 x 420 x 830 SA1020 3 V2 91 ...

Page 3: ...r to cool To restart turn main switch off reset D and then turn main switch on If after restarting the compressor again automatically cuts out turn off at the main switch and contact Service Agent 4 6 SA1050 3 SA1010 3 The output pressure is controlled by a pressure regulator Lift and turn the knob clockwise to increase pressure anticlockwise to reduce push knob down to lock in required position T...

Page 4: ...ge Belt slipping Filter clogged Head gasket or valve fault Pressure switch fault Motor failure Overload cut out operated motor overheating Non return valve seal defective Contact Authorised Service Agent Adjust belt See para 5 6 b Replace filter element Contact Authorised Service Agent Contact Authorised Service Agent Contact Authorised Service Agent Press the button D to restart fig 5 Empty the a...

Reviews: