b) check belt tension. A weight of 3kg applied at the belt mid-point should give a deflection of approx. 10mm (fig.7). If adjustment  

 

 

is required remember to maintain the alignment of the two pulleys (fig.7). Adjust by repositioning motor.

 

c) check all tube fittings and electrical connections.

 

d) Inspect pressure tank inside and out for damage or corrosion.

5.7.   scheduled maintenance table

Maintenance 

Opera

tions

Weekly

3 Monthly

Monthly

500 hrs.

1000 hrs.

drain condensation

check oil level

clean intake filter

check belt tension

check condition of belt 

and pulleys

check tube fittings and 

electrical connections

replace oil

Internal & external 

inspection of tank

General cleaning of 

compressor

replace air filter

check tank for internal  

corrosion

check for oil leaks

Fault

Cause

remedy

Pressure drop in the tank

Air leaks at connections

run compressor to max. pressure, switch off.                   

Brush soap solution over connections and look for 

bubbles. tighten connections showing leaks. 

If problem persists contact Authorised service Agent.

compressor noisy with metallic knock

compressor speed fluctuates

compressor does not reach max. pressure

compressor does not stop at max. pressure

compressor stops and does not restart

compressor stops and does not restart

Pressure switch valve leaks when compressor is idle

Bearing or piston damage

Belt slipping

filter clogged

Head gasket or valve fault

Pressure switch fault

motor failure

overload cut-out operated - motor overheating

non-return valve seal defective

contact Authorised service Agent.

Adjust belt. see para. 5.6.b.

replace filter element.

contact Authorised service Agent.

contact Authorised service Agent.

contact Authorised service Agent.

Press the button ‘d’ to restart (fig.6).

empty the air tank, remove the non-return valve cap 

‘A’ (fig.8) and clean and, if necessary, 

replace the seal ‘B’. 

6.  trOUBle SHOOtinG

5.8. 

recommended oils

 

recommended oil for compressors, suitable for room  

 

temperatures ranging from +5°c to +25°c.

 

seAleY cPo or equivalent sAe 40 compressor oil.

 

room temperature below +5°c: sAe 20 compressor oil.

 

Approximate oil capacity: 0.45 litres.

AliGnMent

fig. 7

A

B

fig. 8

NOTE:

 It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

iMPOrtAnt: 

no liability is accepted for incorrect use of this product. 

WArrAntY: 

Guarantee is 12 months from purchase date, proof of which will be required for any claim. 

inFOrMAtiOn:

 for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

sales@sealey.co.uk

Sole UK Distributor, Sealey Group, 

Kempson Way, suffolk Business Park

Bury st. edmunds, suffolk,

IP32 7Ar

www.sealey.co.uk

Web

email

Original Language Version 

sA2010/3, sA2015/3, sA2020/3, sA2050/3    Issue: 

5  - 06/10/10

Summary of Contents for SA2010/3

Page 1: ...f appropriate safety devices A Residual Current Circuit Breaker RCCB should be incorporated in the main distribution board We also recommend that a Residual Current Device RCD is used It is particularly important to use an RCD with portable products that are plugged into a supply which is not protected by an RCCB If in any doubt consult a qualified electrician You may obtain a Residual Current Dev...

Page 2: ...5 Bar Max At 6 0 Bar Tank Capacity l Max Pressure psi bar Noise Level dB A SA2050 3 3 230 1 13 K12 C 1400 13 6 10 7 10 5 9 6 50 145 10 95 SA2010 3 3 230 1 13 K12 C 1400 13 6 10 7 10 5 9 6 100 145 10 95 SA2020 3 SA2015 3 3 3 230 1 230 1 13 13 K12 C K12 C 1700 1700 14 5 14 5 12 8 12 8 12 1 12 1 11 1 11 1 200 150 145 10 145 10 95 95 2 1 Specifications 2 2 Weights Dimensions fig 3 Model Weight kg Dime...

Page 3: ...eset D fig 6 should not be operated until 3 minutes after cut out to allow the motor to cool To restart turn main switch off reset D and then turn main switch on If after restarting the compressor again automatically cuts out turn off at the main switch and contact Service Agent 4 6 SA2050 3 SA2010 3 The output pressure is regulated by the pressure reducer fig 4 3 Lift and turn the knob clockwise ...

Page 4: ...damage Belt slipping Filter clogged Head gasket or valve fault Pressure switch fault Motor failure Overload cut out operated motor overheating Non return valve seal defective Contact Authorised Service Agent Adjust belt See para 5 6 b Replace filter element Contact Authorised Service Agent Contact Authorised Service Agent Contact Authorised Service Agent Press the button D to restart fig 6 Empty t...

Reviews: