background image

p

 

WARNING!

 

Disconnect wrench from air supply before changing accessories, servicing or 

 

performing maintenance.

 

Replace or repair damaged parts. 

Use genuine parts only. 

 

Non-authorised parts may be dangerous and will invalidate the warranty.

5.1.

  Lubricate the air wrench daily with a few drops of Sealey air tool oil dripped into the air  

 

inlet to prolong its life. 

5.2.

   Clean the wrench after use. 

DO NOT

 use worn, or damaged sockets.

5.3.

   Loss of power or erratic action may be due to the following: 

 

a)

  Excessive drain on the air line. Moisture or restriction in the air pipe. Incorrect size or

 

  type of hose connectors. To remedy check the air supply and follow instructions in 

 

  chapter 3. 

 

b

)  Grit or gum deposits in the wrench may also reduce performance. If your model has an 

 

  air strainer (located in the area of the air inlet), remove the strainer and clean it. Flush  

 

  the wrench out with gum solvent oil or an equal mixture of SAE No 10 oil and paraffin. 

 

  Allow to dry before use. If you continue to experience problems, contact your local 

 

  Sealey service agent. 

5.4.

  For a full service contact your local Sealey service agent. 

5.5.

  When not in use, disconnect from air supply, clean wrench and store in a safe, dry, 

 

childproof location.

5. MAINTENANCE

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: 

No liability is accepted for incorrect use of this product. 

WARRANTY: 

Guarantee is 12 months from purchase date, proof of which will be required for any claim. 

INFORMATION:

 For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

sales@sealey.co.uk

Sole UK Distributor, Sealey Group, 

Kempson Way, Suffolk Business Park

Bury St. Edmunds, Suffolk,

IP32 7AR

www.sealey.co.uk

Web

email

Original Language Version

 SA20/S, SA21/S Issue:4(SP)-17/07/13

 

© Jack Sealey Limited

Summary of Contents for SA21/S

Page 1: ...shoes 3 Keep children and unauthorised persons away from the working area 7 DO NOT use the ratchet for a task it is not designed to perform p WARNING DO NOT use wrench if damaged or thought to be faulty Contact Service Agent 7 DO NOT use wrench unless you have been instructed in its use by a qualified person 7 DO NOT drop throw or abuse the wrench as it is a precision tool 7 DO NOT carry the wrenc...

Page 2: ...ar and make certain that all connections are secure 3 2 Couplings Vibration may cause failure if a quick change coupling is connected directly to the wrench To overcome this connect a leader hose to the wrench A quick change coupling may then be used to connect the leader hose to the air line recoil hose See fig 1 2 3 PREPARING WRENCH FOR USE 4 OPERATING INSTRUCTIONS p WARNING Ensure you read unde...

Page 3: ...gum solvent oil or an equal mixture of SAE No 10 oil and paraffin Allow to dry before use If you continue to experience problems contact your local Sealey service agent 5 4 For a full service contact your local Sealey service agent 5 5 When not in use disconnect from air supply clean wrench and store in a safe dry childproof location 5 MAINTENANCE NOTE It is our policy to continually improve produ...

Page 4: ...possible Ensure that the operator is sufficiently experienced in order to be able to handle and operate the tool correctly Ensure that the tool is held with a light but secure grip Avoid excessive grip force as this will increase the risk of vibration injury MAINTENANCE If the air system does not have an oiler lubricate the air tool daily with a few drops of Sealey air tool oil dripped into the ai...

Reviews: