01284 757500
01284 703534
E-mail:
sales@sealey.co.uk
NOTE:
It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT:
No liability is accepted for incorrect use of this equipment
WARRANTY:
Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION:
For a copy of our latest catalogue call us on 01284 757525 and leave your full name and address, including postcode.
Sole UK Distributor
Sealey Group,
Bury St. Edmunds, Suffolk.
Declaration of Conformity
We, the sole UK importer, declare that the products listed below
are
in conformity with the following
standards and directives.
The construction files for th
ese
products
are
held by the
Manufacturer and may be inspected on request by contacting
Jack Sealey Ltd.
PREMIER LINE COMPRESSORS
Models: SA2110/3, SA2115/3 &
SA2120/3
87/404/EEC Pressure Vessel Directive
89/336/EEC EMC Directive
73/23/EEC LV Directive
98/37/EC Machinery Directive
Signed by Mark Sweetman
1st September 1999
b) Check belt tension. A weight of 3kg applied at the belt mid-point should give a deflection of approx. 10mm (fig.7). If adjustment
is required remember to maintain the alignment of the two pulleys (fig.7). Adjust by repositioning motor.
c) Check all tube fittings and electrical connections.
d) Inspect pressure tank inside and out for damage or corrosion.
5.7.
Scheduled maintenance table
Maintenance
Opera
tions
Daily
3 Monthly
Monthly
500 hrs.
1000 hrs.
Drain condensation
Check oil level
Clean intake filter
Check belt tension
Check condition of belt
and pulleys
Check tube fittings and
electrical connections
Replace oil
General cleaning of
compressor
Internal & external
inspection of tank
Replace air filter
Check tank for internal
corrosion
Check for oil leaks
SA2110/3, SA2115/3 & SA2120/3 - 1069 - (2) -150200
6. TROUBLE SHOOTING
5.8.
Recommended oils
Recommended oil for compressors, suitable for room
temperatures ranging from +5
O
C to +25
O
C.
SEALEY CPO or equivalent SAE 40 compressor oil.
Room temperature below +5
O
C: SAE 20 compressor oil.
Approximate oil capacity: 1.0 litre.
For Jack Sealey Ltd. Sole UK importer of Sealey
Power Products
ALIGNMENT
fig. 7
A
B
fig. 8
Fault
Cause
Remedy
Pressure drop in the tank
Air leaks at connections
Run compressor to max. pressure, switch off.
Brush soap solution over connections and look for
bubbles. Tighten connections showing leaks.
If problem persists contact Authorised Service Agent.
Pressure switch valve leaks when compressor is idle
Non-return valve seal defective
Empty the air tank, remove the non-return valve cap
A (fig.8) and clean the seat B.
If necessary replace the seal.
Compressor stops and does not restart
Overload cut-out operated - motor overheating
Press the button D to restart (fig.6).
Compressor stops and does not restart
Motor failure
Contact Authorised Service Agent.
Compressor does not stop at max. pressure
Pressure switch fault
Contact Authorised Service Agent.
Compressor does not stop at max. pressure
Filter clogged
Head gasket or valve fault
Replace filter element.
Contact Authorised Service Agent.
Compressor speed fluctuates
Belt slipping
Adjust belt. See para. 5.6.b.
Compressor noisy with metallic knock
Bearing or piston damage