background image

01284 757500

01284 703534

E-mail:

sales@sealey.co.uk

NOTE:

It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: 

No liability is accepted for incorrect use of this equipment

WARRANTY: 

Guarantee is 12 months from purchase date, proof of which will be required for any claim.

INFORMATION: 

For a copy of our latest catalogue call us on 01284 757525 and leave your full name and address, including postcode.

Sole UK Distributor

Sealey Group,

Bury St. Edmunds, Suffolk.

Declaration of Conformity  

We, the sole UK importer, declare that the products listed below 

are

in conformity with the following

standards and directives.

The construction files for th

ese

products

are

held by the

Manufacturer and may be inspected on request by contacting

Jack Sealey Ltd.

PREMIER LINE COMPRESSORS 

Models: SA2110/3, SA2115/3  &

SA2120/3

87/404/EEC Pressure Vessel Directive 

89/336/EEC EMC Directive 

73/23/EEC LV Directive

98/37/EC Machinery Directive

Signed by Mark Sweetman

1st September 1999

b) Check belt tension. A weight of 3kg applied at the belt mid-point should give a deflection of approx. 10mm (fig.7). If adjustment

is required remember to maintain the alignment of the two pulleys (fig.7). Adjust by repositioning motor.

c) Check all tube fittings and electrical connections.

d) Inspect pressure tank inside and out for damage or corrosion.

5.7. 

Scheduled maintenance table

Maintenance

Opera

tions

Daily

3 Monthly

Monthly

500 hrs.

1000 hrs.

Drain condensation

•

Check oil level

•

Clean intake filter

•

Check belt tension

•

Check condition of belt

and pulleys

Check tube fittings and

electrical connections

Replace oil

General cleaning of

compressor

Internal & external

inspection of tank

Replace air filter

Check tank for internal

corrosion

Check for oil leaks

•

•

•

•

•

•

•

•

SA2110/3, SA2115/3 & SA2120/3 - 1069 - (2) -150200

6. TROUBLE SHOOTING

5.8.

Recommended oils

Recommended oil for compressors, suitable for room 

temperatures ranging from +5

O

C to +25

O

C.

SEALEY CPO or equivalent SAE 40 compressor oil.

Room temperature below +5

O

C: SAE 20 compressor oil.

Approximate oil capacity: 1.0 litre.

For Jack Sealey Ltd. Sole UK importer of Sealey 

Power Products

ALIGNMENT

fig. 7

A

B

fig. 8

Fault

Cause

Remedy

Pressure drop in the tank

Air leaks at connections

Run compressor to max. pressure, switch off.

Brush soap solution over connections and look for

bubbles. Tighten connections showing leaks. 

If problem persists contact Authorised Service Agent.

Pressure switch valve leaks when compressor is idle

Non-return valve seal defective

Empty the air tank, remove the non-return valve cap

‘A’ (fig.8) and clean the seat ‘B’.

If necessary replace the seal. 

Compressor stops and does not restart

Overload cut-out operated - motor overheating

Press the button ‘D’ to restart (fig.6).

Compressor stops and does not restart

Motor failure

Contact Authorised Service Agent.

Compressor does not stop at max. pressure

Pressure switch fault

Contact Authorised Service Agent.

Compressor does not stop at max. pressure

Filter clogged

Head gasket or valve fault

Replace filter element.

Contact Authorised Service Agent.

Compressor speed fluctuates

Belt slipping

Adjust belt. See para. 5.6.b.

Compressor noisy with metallic knock

Bearing or piston damage

Contact Authorised Service Agent.

Summary of Contents for SA2110/3

Page 1: ...ctions for wear or damage You must ensure the risk of electric shock is minimised by the installation of appropriate safety devices An RCCB Residual Current Circuit Breaker should be incorporated in the main distribution board We also recommend that an RCD Residual Current Device is used with all electrical products It is particularly important to use an RCD with portable products that are plugged...

Page 2: ...ed 3 6 Confirm that the oil level is at the maximum mark on the sight glass fig 3 fig 1 Free Air Delivery cfm Model Max Motor Output hp Voltage Phase Current A Pump Type Pump Speed rpm Piston Displacement cfm At 2 5 Bar Max At 6 0 Bar Tank Capacity l Max Pressure psi bar Noise Level dB A SA2110 3 3 230 1 13 K17 1180 14 9 11 6 12 0 10 6 100 145 10 73 SA2115 3 3 230 1 13 K17 1180 14 9 11 6 12 0 10 6...

Page 3: ...quipped with an overload cut out to protect the motor The manual reset D fig 6 should not be operated until 3 minutes after cut out to allow the motor to cool To restart turn main switch off reset D and then turn main switch on If after restarting the compressor again automatically cuts out turn off at the main switch and contact Service Agent 4 6 SA2110 3 The output pressure is regulated by the p...

Page 4: ...oil level Clean intake filter Check belt tension Check condition of belt and pulleys Check tube fittings and electrical connections Replace oil General cleaning of compressor Internal external inspection of tank Replace air filter Check tank for internal corrosion Check for oil leaks SA2110 3 SA2115 3 SA2120 3 1069 2 150200 6 TROUBLE SHOOTING 5 8 Recommended oils Recommended oil for compressors su...

Reviews: