background image

  I n s t r u c t I o n   m a n u a l  f o r :

six litre COMPressOr

model no

:          

sA2306

thank  you  for  purchasing  a  sealey  product.  manufactured  to  a  high  standard  this  product  will,  if  used  according  to  these  instructions 

and properly maintained, give you years of trouble free performance.

sa2306  - 2 - 010208

IMPORTANT:

 

PleAse reAD tHese iNstrUCtiONs CAreFUllY. NOte tHe sAFe OPerAtiONAl reQUireMeNts, WArNiNGs & CAUtiONs. 

Use  tHe  PrODUCt  COrreCtlY  AND  WitH  CAre  FOr  tHe  PUrPOse  FOr  WHiCH  it  is  iNteNDeD.  FAilUre  tO  DO  sO  MAY  CAUse 

DAMAGe AND/Or  PersONAl  iNJUrY AND  Will  iNVAliDAte  tHe  WArrANtY.  PleAse  KeeP  iNstrUCtiONs  sAFe  FOr  FUtUre  Use.

1.2.   GeNerAl sAFetY iNstrUCtiONs

familiarise yourself with the application and limitations of the compressor.     

ensure that the compressor is in good order and condition before use. If in any doubt do    

 

not use. contact an electrician/service agent.

  WArNiNG! 

the compressor must be serviced by an authorised agent only. DO NOT  

 

tamper with, or attempt to adjust, the pressure switch or the safety valve.

Before moving, or maintaining the compressor

 

ensure that it is unplugged from the mains  

 

supply and that the air tank pressure has been vented. 

only use recommended parts and accessories. to use unauthorised items may be  

 

 

dangerous and will invalidate your warranty.

read the instructions regarding any accessory used with the compressor. ensure that  

 

the safe working pressure of any air appliance used exceeds the output pressure of the    

 

compressor.

ensure that the air supply valve is turned off before disconnecting the air supply hose.

Keep tools and other items away from the compressor when it is in use and keep the    

 

area clean and free of unrelated items.

ensure that the air hose is not tangled, twisted or pinched.

Keep children and unauthorised persons away from the work area.

DO NOt

 dis-assemble compressor for any reason. the unit must be checked by qualified personnel only.

DO NOt

 use the compressor outdoors, or in damp, or wet, locations and 

DO NOt

 operate it within the vicinity of flammable liquids, gases or solids.

DO NOt

 touch compressor cylinder, cylinder head or pipe from head to tank as these may be hot and will remain so for some time after shutdown.

DO NOt

 attempt to move the compressor by pulling the air supply hose. only move the compressor by the handle.

DO NOt

 attempt to lift or move the compressor by any means other than by the handle. 

 

use the compressor in a well ventilated area and ensure that it is placed on a firm, level surface.

1.1.   eleCtriCAl sAFetY

  

WArNiNG! 

It is the responsibility of the owner and the operator to read, understand and comply with the following:

You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and any other 

connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices. 

a residual current circuit Breaker (rccB) should be incorporated in the main distribution board. We also recommend that a residual current 

device (rcd) is used. It is particularly important to use an rcd with portable products that are plugged into a supply which is not protected 

by an rccB. If in any doubt consult a qualified electrician. You may obtain a residual current device by contacting your sealey dealer. 

You must

 also read and understand the following instructions concerning electrical safety.

1.1.1.  the 

electricity at Work Act 1989 

requires all portable electrical appliances, if used on business premises, to be tested by a qualified  

 

electrician, using a Portable appliance tester (Pat), at least once a year.

1.1.2.  the 

Health & safety at Work Act 1974 

makes owners of electrical appliances responsible for the safe condition of those appliances  

 

and the safety of the appliance operators. 

if in any doubt about electrical safety, contact a qualified electrician.

1.1.3.  ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. see 1.1.1. and 1.1.2.  

 

and use a Portable appliance tester.

1.1.4.  ensure that cables are always protected against short circuit and overload.

1.1.5.  regularly inspect power supply cables and plugs for wear or damage and check all  

 

connections to ensure that none is loose.

1.1.6. 

important:

 ensure that the voltage marked on the appliance matches the power supply 

 

to be used and that the plug is fitted with the correct fuse - see fuse rating at right.

1.1.7. 

DO NOt

 pull or carry the appliance by the power cable.

1.1.8. 

DO NOt 

pull the plug from the socket by the cable.

1.1.9. 

DO NOt

 use worn or damaged cables, plugs or connectors. Immediately have any faulty 

 

item repaired or replaced by a qualified electrician. When an asta/Bs approved uK 

 

3 pin plug is damaged, cut the cable just above the plug and 

dispose of the plug safely. 

 

fit a new plug according to the following instructions (uK only).

 

a)  Connect the GreeN/YellOW earth wire to the earth terminal ‘e’.

 

b)  Connect the BrOWN live wire to the live terminal ‘l’.

 

c)  Connect the BlUe neutral wire to the neutral terminal ‘N’.

 

d)  After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable outer insulation  

 

extends beyond the cable restraint and that the restraint is tight.

 

double insulated products, which are always marked with this symbol    , are fitted with live (brown) and neutral (blue) wires only.  

 

to rewire, connect the wires as indicated above - 

DO NOt

 connect either wire to the earth terminal.

1.1.10.  Products which require more than 13 amps are supplied without a plug. In this case you must contact a qualified electrician to ensure  

 

that a 30 amp supply is available. We recommend that you discuss the installation of an industrial round pin plug and socket with your electrician.

1.1.11.  If an extension reel is used it should be fully unwound before connection. a reel with an rcd fitted is preferred since any appliance  

 

plugged into it will be protected. the section of the cores in the cable is important and should be at least 1.5mm2, but to be  

 

 

absolutely sure that the capacity of the reel is suitable for this product and for others which may be used in the other output sockets, we  

 

recommend the use of 2.5mm

2

 section cable. 

1.  sAFetY iNstrUCtiONs

rAtiNG

 

13 AMP

Blue 

Neutral 

Wire

Yellow & Green 

Earth Wire 

Cable 

Restraint

Brown

Live 

Wire

Summary of Contents for SA2306

Page 1: ...e RCD is used It is particularly important to use an RCD with portable products that are plugged into a supply which is not protected by an RCCB If in any doubt consult a qualified electrician You may obtain a Residual Current Device by contacting your Sealey dealer You must also read and understand the following instructions concerning electrical safety 1 1 1 The Electricity at Work Act 1989 requ...

Page 2: ...ols for use with the compressor Air tool manufacturers normally express the volume of air required to operate a tool in cubic feet per minute cfm This refers to free air delivered by the compressor air out which varies according to the pressure setting Do not confuse this with the compressor displacement which is the air taken in by the compressor air in Air out is always less than air in due to l...

Page 3: ... maximum at which point the compressor will automatically cut out Tank pressure is shown on the larger gauge fig 4 6 5 9 Fully open the air outlet valve by turning it through 180 5 10 Begin to gradually open the regulator by turning the knob anticlockwise until the small gauge registers the required operating pressure specified for the tool to be used Always adjust up to the required pressure rath...

Page 4: ...nk Air leaks from safety valve Operate the safety valve manually by pulling on the ring If valve continues to leak when in the closed position it should be replaced 1C Pressure drop in the tank Air leaks from cylinder head gasket Check tightness of head bolts If leak continues contact authorised service agent 2 Pressure switch valve leaks when compressor is idle Non return valve seal defective Emp...

Reviews: