background image

2. INTRODUCTION & SPECIFICATIONS

Ideal for use where an oil-free air delivery is required and especially suited to small low pressure, touch-up and airbrush spraying applications

as well as general-purpose applications. Simple construction with fewer components makes these units practically maintenance-free. Reduced

weight gives greater portability and compressor can be transported and even operated on its side. All models are supplied with a precision

welded receiver tank, manufactured to meet Pressure Vessel Directive 87/404/EEC, fully automatic pressure cut-out switch and air regulator

with gauge. All have a handle and wheels and ASTA/BS approved non-rewirable plug.

3. PREPARATION

3.1

Remove compressor from packaging and inspect for any shortages or damage. If anything is found to be missing or damaged contact your supplier.

3.2

Save the packing material for future transportation of the compressor. We recommend that you store the packing in a safe location, at

least for the period of the guarantee. Then, if necessary, it will be easier to send the compressor to the service centre.

3.3

Confirm that the mains voltage supply corresponds with the voltage shown on the compressor data plate.

3.4

The compressor should be operated in a position that allows good air circulation around the unit.

7

7

DO NOT

attempt to move the compressor by pulling the air tool’s hose. Only move the compressor by its handle.

7

7

DO NOT

use this product to perform a task for which it has not been designed.

7

7

DO NOT

deface the certification plate attached to the tank. 

7

7

DO NOT

cover the compressor or restrict air flow around the machine whilst operating.

s

s

DANGER! DO NOT direct the output jet of air towards people or animals.

7

7

DO NOT

allow anyone to operate the compressor unless they have received full instructions.

WARNING! The air tank is a pressure vessel and the following safety measures apply:

7

7

DO NOT tamper with the safety valve. 

7

7

DO NOT modify or alter the tank in any way and DO NOT strap anything to the tank.

7

7

DO NOT subject the tank to impacts, vibration or to heat. 

7

7

DO NOT allow contact with abrasives or corrosives.

4

4

DO drain condensation from tank daily and inspect inside walls for corrosion every 12 months. The tank shell must not fall 

below the certified thickness at any point. 

p

p

 

 

WARNING! If an electrical fuse blows, ensure it is replaced with an identical fuse type and rating.

When not in use, store the compressor carefully in a safe, dry, childproof location.

Model No: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SA951015

Motor Output:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.5hp

Voltage/Phase: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .230V - 1ph

Input Current:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5A

Air Displacement:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6.7cfm

Max. Free Air Delivery:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5.9cfm

Tank Capacity:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10ltr

Max. Pressure:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .116psi/8bar

Model No: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SA952515

Motor Output:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.5hp

Voltage/Phase: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .230V - 1ph

Input Current:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5A

Air Displacement:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6.7cfm

Max. Free Air Delivery:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5.9cfm

Tank Capacity:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25ltr

Max. Pressure:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .116psi/8bar

Model No: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SA955015

Motor Output:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.5hp

Voltage/Phase: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .230V - 1ph

Input Current:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5A

Air Displacement:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6.7cfm

Max. Free Air Delivery:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5.9cfm

Tank Capacity:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50ltr

Max. Pressure:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .116psi/8bar

SA951015, SA952515 & SA955015 - 1 - 310105

Model No. SA955015

Summary of Contents for SA951015

Page 1: ...ase you must contact a qualified electrician to ensure that a suitably rated supply is available We recommend that you discuss the installation of an industrial round pin plug and socket with your electrician 1 1 11 If an extension reel is used it should be fully unwound before connection A reel with an RCD fitted is preferred since any appliance plugged into it will be protected The cable core se...

Page 2: ...ct to perform a task for which it has not been designed 7 7 DO NOT deface the certification plate attached to the tank 7 7 DO NOT cover the compressor or restrict air flow around the machine whilst operating s s DANGER DO NOT direct the output jet of air towards people or animals 7 7 DO NOT allow anyone to operate the compressor unless they have received full instructions p WARNING The air tank is...

Page 3: ...sure The pressure applied to the tool is shown on the output pressure gauge fig 1 7 4 3 3 Turn on tap fig 1 3 NOTE To determine the correct working pressure and air flow requirements for any piece of equipment check the corresponding manual Be aware that the air flow figure stated on tools and accessories refers to Free Air Delivery and not the piston displacement of the compressor 4 3 4 To discon...

Page 4: ...ose leaking The head screws are too tight item 15 Bearing fault Back off 1 4 turn Check seals or renew hose Loosen the screws and then tighten them equally do not overtighten Return to dealer for checking Safety valve operates below max pressure Faulty valve www sealey co uk 01284 757500 01284 703534 sales sealey co uk Web email Sole UK Distributor Sealey Group Bury St Edmunds Suffolk NOTE It is o...

Reviews: