2. INTRODUCTION & SPECIFICATIONS
The SA9925/1.5 & /2 and the SA9950/2 Direct Drive Compressors have single cylinder pumps powered by 230V 1ph motors and are capable
of supplying air at up to 8 bar from a 25 litre tank in the case of SA9925 models, and a 50 litre tank in the case of the SA9950/2. In addition to
pneumatic tools, the compressors may be connected to accessories suitable for blowing, washing and spraying. All compressors have two
rear wheels and a handle for ease of movement.
SA9925/1.5 & /2 & SA9950/2 - 1069 - (2) - 280600
3. PREPARATION
3.1.
Remove compressor from packaging and inspect for any shortages or damage. If anything is found to be missing or damaged contact your supplier.
3.2.
Save the packing material for future transportation of the compressor. We recommend that you store the packing in a safe location, at
least for the period of the guarantee. Then, if necessary, it will be easier to send the compressor to the service centre.
3.3.
Confirm that the mains voltage corresponds with the voltage shown on the compressor data plate.
3.4.
The compressor should be operated on a flat surface, or one that does not exceed 15
O
either transversely or longitudinally (fig.1), and
should be in a position that allows good air circulation around the unit.
3.5.
Replace transit plug in oil filler aperture with filler plug ( para.5.4.A) provided.
3.6.
Confirm oil level is at maximum mark on the sight glass (fig.2).
3.7.
Screw air filter (fig.3.A) into inlet port.
fig. 1
fig. 3
Free Air Delivery
(cfm)
Model
Motor
Output
(hp)
Voltage/
Phase
Current
(A)
Pump
Type
Pump
Speed
(rpm)
Piston
Displacement
(cfm)
At
2.5 Bar*
Max.
At
6.0 Bar*
Tank
Capacity
(l)
Max.
Pressure
(psi/bar)
Noise
Level
(dB.A)
SA9925/1.5
1.5
230/1
7
D10
2850
7.4
6.5
6.9
5.5
25
116/8
84
SA9925/2
2
230/1
8.5
D11
2850
8.8
7.4
7.8
6.5
25
116/8
85
SA9950/2
2
230/1
8.5
D11
2850
8.8
7.8
7.4
6.5
50
116/8
85
2.1.
Specifications
* Note:
2.5 bar is recommended pressure setting for spraying
6.0 bar is recommended pressure setting for air tools
2.2.
Weights & Dimensions
Model
Weight
(kg)
Dimensions
Length x Width x Height (mm)
SA9925/1.5
21
600 x 300 x 650
SA9925/2
22
600 x 300 x 655
SA9950/2
35
620 x 375 x 725
fig. 2
DO NOT cover the compressor or restrict air flow around the machine whilst operating.
s
DANGER!
DO NOT direct the output jet of air towards people or animals.
DO NOT
operate the compressor without an air filter.
DO NOT
allow anyone to operate the compressor unless they have received full instructions.
p
WARNING!
The air tank is a pressure vessel and the following safety measures apply:
DO NOT tamper with the safety valve and DO NOT modify or alter the tank in any way and DO NOT strap anything to the tank.
DO NOT subject the tank to impact,
vibration
or to heat and DO NOT allow contact with abrasives or corrosives.
DO drain condensation from tank daily and inspect inside walls for corrosion every three months and have a detailed tank inspection
carried out annually.
The tank shell must not fall below the certified thickness at any point.
p
WARNING!
If an electrical fuse blows, ensure it is replaced with an identical fuse type and rating.
When not in use, store the compressor carefully in a safe, dry, childproof location.
All performance figures are ± 5%