background image

1.1.

ELECTRICAL SAFETY. 

WARNING! It is the user’s responsibility to read, understand and comply with the following:

You must check all electrical equipment and appliances to ensure they are safe before using. You must inspect power supply leads, plugs and

all electrical connections for wear or damage. You must ensure the risk of electric shock is minimised by the installation of appropriate safety

devices. An RCCB (Residual Current Circuit Breaker) should be incorporated in the main distribution board. We also recommend that an RCD

(Residual Current Device) is used with all electrical products. It is particularly important to use an RCD with portable products that are plugged

into an electrical supply not protected by an RCCB. If in doubt consult a professional electrician. You may obtain a Residual Current Device by

contacting your Sealey dealer. 

You must

also read and understand the following instructions concerning electrical safety.

1.1.1. The 

Electricity At Work Act 1989

requires all portable electrical appliances, if used on business premises, to be tested by 

a qualified electrician, at least once a year, using a Portable Appliance Tester (PAT).

1.1.2. The 

Health & Safety at Work Act 1974

makes owners of electrical appliances responsible for the safe condition of those appliances, 

and the safety of appliance operators. 

If in any doubt about electrical safety, contact a qualified electrician.

1.1.3. Ensure the insulation on all cables and the product itself is safe before connecting to the mains power supply. 

See 1.1.1. & 1.1.2. above and use a Portable Appliance Tester (PAT).

1.1.4. Ensure that cables are always protected against short circuit and overload.

1.1.5. Regularly inspect power supply leads and plugs for wear or damage and connections to ensure that none is loose. 

1.1.6.

Important:

Ensure the voltage marked on the product is the same as the electrical power supply

to be used, and check that plugs are fitted with the correct capacity fuse. A 13Amp plug may require 

a fuse smaller than 13Amps for certain products (

subject to 1.1.10. below) -

see fuse rating at right. 

1.1.7.

DO NOT

pull or carry the powered appliance by its power supply lead. Products such as

welders must not be pulled or carried by their output cables.

1.1.8.

DO NOT

pull power plugs from sockets by the power cable.

1.1.9.

DO NOT

use worn or damage leads, plugs or connections. Immediately replace or have repaired by 

a qualified electrician. Where a U.K. 3 pin plug with ASTA/BS approval is fitted, in case of damage, cut off 

and fit a new plug according to the following instructions (discard old plug safely).

(UK only - see diagram at right). 

Ensure the unit is correctly earthed via a three-pin plug. 

a)  Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

b) Connect the BROWN live wire to the live terminal ‘L’.

c)  Connect the BLUE neutral wire to the neutral terminal ‘N’.

After wiring, check there are no bare wires, that all wires have been correctly connected, that the cable outer insulation 

extends past the cable restraint and that the cable restraint is tight.

Double insulated products are often fitted with live (BROWN) and neutral (BLUE) wires only. Double insulated products are always marked with

this symbol      . 

To re-wire, connect the brown & blue wires as indicated above. DO NOT 

connect the brown or blue wires to the earth terminal.

1.1.10.

NOTE: 

If this product requires more than a 13Amp electrical supply, then 

NO

plug is fitted. 

You must

therefore contact a qualified electrician to ensure 

a 30 amp fused supply is available. We recommend you discuss the installation of a industrial round pin plug & socket with your electrician. 

1.1.11.

Cable extension reels

. When a cable extension reel is used it should be fully unwound before connection. A cable reel with an RCD

fitted is recommended since any product which is plugged into the cable reel will be protected. The section of the cores in the cable

is important and should be at least 1.5mm

2

, but to be absolutely sure that the capacity of the cable reel is 

suitable for this product and for others that may be used in the other output sockets, we recommend the use of 2.5mm

2

section.

INSTRUCTIONS FOR:

DIRECT DRIVE COMPRESSORS

MODELS

:

SA9925/2, SA9925/2.5

& SA9950/2.5

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions 

and properly maintained, give you years of trouble free performance.

SA9925/2 & /2.5 & SA9950/2.5 - 1069 - (1) - 070601

1. SAFETY INSTRUCTIONS

IMPORTANT:

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS.

USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE

DAMAGE OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.

Blue

Neutral 

Wire

Yellow & Green 

Earth Wire 

Cable 

Restraint

FUSE RATING

THE PLUG FITTED TO PRODUCT 

MUST BE EQUIPPED WITH A 

13 AMP FUSE

Brown

Live 

Wire

1.2. 

GENERAL SAFETY INSTRUCTIONS

Familiarise yourself with the application and limitations of the compressor. 

Ensure the compressor is in good order and condition before use. If in any doubt do not use the unit and contact an electrician/service agent.

p

WARNING! 

Compressor must only be serviced by an authorised agent. DO NOT tamper with, or attempt to adjust, pressure switch or safety valve.

Before moving, or maintaining the compressor ensure it is unplugged from the mains supply and that the air tank pressure has been vented. 

Only use recommended attachments and parts. To use non-recommended items may be dangerous and will invalidate your warranty.

Read the instructions regarding any accessory used with the compressor. Ensure the safe working pressure of any air appliance used exceeds

unit’s output pressure. If using spray gun, check that the area selected for spraying is provided with air change system/ventilation.

Ensure the air supply valve is turned off before disconnecting the air supply hose.

To move the compressor use the handle only.  Lift the compressor so that the front leg gives enough clearance for manoeuvring but maintain

unit’s centre of gravity in front of the wheels. DO NOT attempt to lift or move the compressor by any means other than by the handle. 

Use the compressor in a well ventilated area and ensure it is placed on a firm surface.

Keep tools and other items away from the compressor when it is in use, and keep area clean and clear of unnecessary items.

Ensure the air hose is not tangled, twisted or pinched.

Keep children and unauthorised persons away from the working area.

DO NOT

dis-assemble compressor for any reason. The unit must be checked by qualified personnel only.

DO NOT

use the compressor outdoors, or in damp, or wet, locations and DO NOT operate within the vicinity of flammable liquids, gases or solids.

DO NOT

touch compressor cylinder, cylinder head or pipe from head to tank as these may be hot and will remain so for some time after shutdown.

DO NOT

attempt to move the compressor by pulling the air tool hose. Only move the compressor by the handle.

DO NOT

use this product to perform a task for which it has not been designed.

DO NOT

deface the certification plate attached to the end of the compressor tank.

Summary of Contents for SA9925/2

Page 1: ... is available We recommend you discuss the installation of a industrial round pin plug socket with your electrician 1 1 11 Cable extension reels When a cable extension reel is used it should be fully unwound before connection A cable reel with an RCD fitted is recommended since any product which is plugged into the cable reel will be protected The section of the cores in the cable is important and...

Page 2: ...put hp Voltage Phase Current A Pump Type Pump Speed rpm Piston Displacement cfm At 2 5 Bar Max At 6 0 Bar Tank Capacity l Max Pressure psi bar Noise Level dB A SA9925 2 2 230 1 8 5 D10 R 2850 8 7 7 3 7 7 6 3 25 116 8 82 SA9925 2 5 2 5 230 1 9 5 D11 R 2850 9 5 8 1 8 4 7 0 25 116 8 82 SA9950 2 5 2 5 230 1 9 5 D11 R 2850 9 5 8 4 8 1 7 0 50 116 8 82 2 1 Specifications Note 2 5 bar is recommended press...

Page 3: ...he compressor air out which varies according to the pressure setting Do not confuse this with the compressor displacement which is the air taken in by the compressor air in Air out is always less than air in due to losses within the compressor and so it is important that before choosing equipment you study the Free Air Delivery figures shown in the Specification chart section 2 p WARNING Ensure th...

Page 4: ... out for damage or corrosion 5 6 Scheduled maintenance table 5 7 Recommended oils Recommended oil for compressors suitable for room temperatures ranging from 5O C to 25O C SEALEY CPO or equivalent SAE 40 compressor oil Room temperature below 5O C SAE 20 compressor oil Approximate oil capacity 0 16 litres fig 5 6 TROUBLE SHOOTING Internal external inspection of tank General cleaning of compressor C...

Reviews: