background image

1.1.  ELECTRICAL SAFETY

  

WARNING!

 It is the responsibility of the owner and the operator to 

read, understand and comply with the following: You must check all 

electrical products, before use, to ensure that they are safe. You must 

inspect power cables, plugs, sockets and any other connectors for wear 

or damage. You must ensure that the risk of electric shock is minimised 

by the installation of appropriate safety devices. A Residual Current 

Circuit Breaker (RCCB) should be incorporated in the main distribution 

board. We also recommend that a Residual Current Device (RCD) is 

used. It is particularly important to use an RCD with portable products 

that are plugged into a supply which is not protected by an RCCB. If in 

any doubt consult a qualified electrician. You may obtain a Residual 

Current Device by contacting your Sealey dealer. You must also read and 

understand the following instructions concerning electrical safety.

1.1.1. The 

Electricity at Work Act 1989

 requires that all portable  

 

 

electrical appliances, if used on business premises, are  

 

 

tested by a qualified electrician, using a Portable Appliance  

 

 

Tester (PAT), at least once a year.

1.1.2. The 

Health & Safety at Work Act 1974

 makes owners of  

 

 

electrical appliances responsible for the safe condition of  

 

 

those appliances and the safety of the appliance operators. 

 

If in any doubt about electrical safety, contact a qualified    

 electrician.

1.1.3.  Ensure that the insulation on all cables and on the appliance is   

 

safe before connecting it to the power supply. See 1.1.1. and    

 

1.1.2. and use a Portable Appliance Tester.

1.1.4.  Ensure that cables are always protected against short circuit    

 

and overload.

1.1.5.  Regularly inspect power supply cables and plugs for wear or    

 

damage and check all connections to ensure that none is loose.

1.1.6. 

Important:

 Ensure that the voltage marked on the appliance    

 

matches the power supply to be used and that the plug is fitted   

 

with the correct fuse - see fuse rating below.

1.1.7. 

DO NOT

 pull or carry the appliance by the power cable.

1.1.8. 

DO NOT

 pull the plug from the socket by the cable.

1.1.9. 

DO NOT

 use worn or damaged cables, plugs or connectors.    

 

Have any faulty item repaired or replaced immediately by a  

 

 

qualified electrician. When a BS 1363/A UK 3 pin plug is  

 

 

damaged, cut the cable just above the plug and dispose of the   

 

plug 

safely. 

 

      

 

Fit a new plug according to the following instructions (UK only).

 

a) Connect the GREEN/YELLOW earth wire to the earth  

 

 

terminal ‘E’.

 

b) Connect the BROWN live wire to the live terminal ‘L’.

 

c) Connect the BLUE neutral wire to the neutral terminal ‘N’.

 

d) After wiring, check that there are no bare wires, that all    

 

wires have been connected

 correctly, that the cable outer    

 

insulation extends beyond the   

 

cable restraint and that the  

 

 

restraint is tight.

 

Double insulated products, which  

 

are always marked with this  

 

 

symbol    , are fitted with live  

 

 

(brown) and neutral (blue) wires    

 

only. To rewire, connect the wires  

 

as indicated in diagram. 

DO NOT

  

 

connect either wire to the earth    

 terminal.

1.1.10.Products which require more than  

 

13A are supplied without a plug. In  

 

this case you must contact a  

 

 

qualified electrician to ensure that  

 

a suitably rated supply is available. 

 

 

INSTRUCTIONS FOR:

COMPRESSOR 100ltr  V-Twin DIRECT DRIVE 3hp

 

MODEL No:

 

SAC10030VE

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly 

maintained, give you years of trouble free performance.

1.  SAFETY INSTRUCTIONS

IMPORTANT:

 

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE 

THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE OR 

PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.

SAC10030VE    Issue No: 2(I) - 17/04/14

  

We recommend that you discuss the installation of an  

 

 

  industrial round pin plug and socket with your electrician.

  

 

IMPORTANT!

  The use of extension leads to connect these   

 

  compressors to the mains is not recommended as the  

 

 

  resulting voltage drop reduces motor, and therefore pump    

 

 performance.

1.2.    GENERAL SAFETY 

3  

 

Familiarise yourself with the application and limitations of the  

 

  compressor.   

 

3  

 

Ensure the compressor is in good order and condition before  

 

  use. If in any doubt do not use the unit and contact an  

 

 

  electrician/service agent.

  

  WARNING! 

Compressor must only be serviced by an    

 

  authorised agent. DO NOT tamper with, or attempt to    

 

  adjust, pressure switch or safety valve.

3  

 

Before moving, or maintaining the compressor ensure it is    

 

  unplugged from the mains supply and that the air tank  

 

 

  pressure has been vented. 

3  

 

Maintain the compressor in good condition and replace any   

 

  damaged or worn parts. Use genuine parts only.    

 

  

Unauthorised parts may be dangerous and will invalidate    

 

  your warranty.

3  

 

Read the instructions relating to any accessory to be used    

 

  with this compressor. Ensure the safe working pressure of    

 

  any air appliance used exceeds compressors output  

 

 

  pressure. If using a spray a gun, check that the area selected  

 

  for spraying is provided with an air change/ventilation system.

3  

 

Ensure the air supply valve is turned off before disconnecting  

 

  the air supply hose.

3  

 

To move the compressor use the handle only. Maintain unit’s  

 

  centre of gravity when lifting. 

DO NOT

 attempt to lift or move  

 

  the compressor by any other means.

RECOMMENDED 

FUSE RATING:

  

13A

Original Language Version

© Jack Sealey Limited

Guide to symbols

 

  

Warning: 

Electricity

 

  

Warning: 

Hot Surface

 

  

Warning: 

Automatic  

 

   

start up

 

 

   Wear ear protection

 

  

Read the instruction  

 

  manual before use

 

DO NOT

 open the air    

 

cock before an air hose  

 

is attached

 

  

 

DO NOT

 operate the    

 

compressor with 

 

enclosure displaced  

 

Ensure oil level is 

 

correct before first use

 

  

 

Summary of Contents for SAC10030VE

Page 1: ... insulated products which are always marked with this symbol are fitted with live brown and neutral blue wires only To rewire connect the wires as indicated in diagram DO NOT connect either wire to the earth terminal 1 1 10 Products which require more than 13A are supplied without a plug In this case you must contact a qualified electrician to ensure that a suitably rated supply is available INSTR...

Page 2: ...pply Section 1 safety instructions 4 1 IMPORTANT The use of extension leads to connect this compressor to the mains is not recommended as the resulting voltage drop reduces motor and therefore pump performance and could damage your compressor 4 2 Take care when selecting tools for use with the compressor Air tool manufacturers normally express the volume of air required to operate a tool in cubic ...

Page 3: ...to maximum pressure Make sure that pressure in the tank rises and that the compressor stops automatically when the max pressure value allowed written on the specification plate and shown on the gauge fig 3 5 is achieved The compressor will now operate automatically The pressure switch fig 3 7 stops the motor when the maximum tank pressure is reached and restarts it when pressure falls below the mi...

Page 4: ... return valve cap 3 spring 2 and seal 1 Clean the seal and its seat or if necessary replace the seal 3 Air leaks from tank body or tank welds Internal corrosion caused by infrequent tank draining or non permitted modifications to tank Tank could rupture or explode Cannot be repaired DISCONTINUE USE IMMEDIATELY 4A Motor stops and will not restart Thermal cut out has operated Allow unit to cool for ...

Reviews: