background image

Original Language Version

7.  tROUBLESHOOtiNG  

FAULt

CAUSE

REMEdY

1A)  Pressure drop in the tank

Air leaks at connections

run  compressor  to  max.  pressure,  switch  off                   

Brush soap solution over connections and look for 

bubbles. tighten connections showing leaks 

If problem persists contact Authorised service Agent

1B)  Pressure drop in the tank

Air leaks from safety valve

operate the safety valve manually by pulling on the 

ring. If valve continues to leak when in the closed 

position it should be replaced

1c)  Pressure drop in the tank

Air leaks from cylinder head gasket

check tightness of head bolts. If leak continues 

contact authorised service agent

2)  Pressure switch valve leaks when 

    compressor is idle

non-return valve seal defective

empty the air tank. referring to fig.6, remove the 

non-return valve cap (3), spring (2) and seal (1) 

clean the seal and its seat, or if necessary replace 

the seal

3)  Air leaks from tank body or tank welds

Internal corrosion caused by infrequent tank 

draining or non permitted modifications to tank

tank could rupture or explode. Beyond repair 

diSCONtiNUE USE iMMEdiAtELY

4A)  motor stops and will not restart

thermal cut out has operated

Allow unit to cool for 30 minutes before restarting

4B)  motor stops and will not restart

supply fuse has tripped

reset fuse and restart unit. If repeated tripping 

occurs replace the check valve or contact 

authorised service agent

5)  compressor stops and does not restart

motor failure

contact Authorised service Agent

6A)   compressor does not stop at max. pressure

Pressure switch fault

contact Authorised service Agent

6B)   compressor does not stop at max. pressure

filter clogged

Head gasket or valve fault

replace filter element

contact Authorised service Agent

7)  compressor noisy with metallic knock

Bearing or piston damage

contact Authorised service Agent

8)  excessive moisture in discharged air

High humidity environment

drain tank after each use

NOTE:

 It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

iMPORtANt: 

no liability is accepted for incorrect use of this product. 

WARRANtY: 

Guarantee is 12 months from purchase date, proof of which will be required for any claim. 

iNFORMAtiON:

 for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

sales@sealey.co.uk

Sole UK distributor, Sealey Group, 

Kempson Way, suffolk Business Park

Bury st. edmunds, suffolk,

IP32 7Ar

www.sealey.co.uk

Web

email

fig.6  

Parts support is available for this product. to obtain a parts listing and/or diagram, please log on to www.sealey.co.uk, 

email sales@sealey.co.uk or phone 01284 757500.

© Jack sealey limited

sAc2420e110V     Issue no: 4 (I) - 15/07/13

Summary of Contents for SAC2420E110V

Page 1: ...safe You must inspect power cables plugs sockets and any other connectors for wear or damage You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices A Residual Current Circuit Breaker RCCB should be incorporated in the main distribution board We also recommend that a Residual Current Device RCD is used It is particularly important to use an RC...

Page 2: ... these may be hot 7 DO NOT use this product to perform a task for which it has not been designed 7 DO NOT deface the certification plate attached to the compressor tank 7 DO NOT cover the compressor or restrict air flow around the unit whilst operating q DANGER DO NOT direct the output jet of air towards people or animals 7 DO NOT operate the compressor without an air filter 7 DO NOT allow anyone ...

Page 3: ...sential 6 1 After the first 50 working hours replace the lubricating oil see paragraph 6 4 fig 5 b The main gauge fig 5 6 indicates the pressure inside the main tank NOT the pressure supplied to the air equipment which is shown on the smaller gauge fig 5 5 Should the pressure in the main tank exceed the pre set switch fig 5 8 maximum the safety valve fig 5 7 will activate WARNING For this reason D...

Page 4: ...restart unit If repeated tripping occurs replace the check valve or contact authorised service agent 5 Compressor stops and does not restart Motor failure Contact Authorised Service Agent 6A Compressor does not stop at max pressure Pressure switch fault Contact Authorised Service Agent 6B Compressor does not stop at max pressure Filter clogged Head gasket or valve fault Replace filter element Cont...

Reviews: