Summary of Contents for SAC32055B

Page 1: ... with correct capacity fuse 1 1 7 DO NOT pull or carry the powered appliance by its power supply lead or output cables 1 1 8 DO NOT pull power plugs from sockets by the power cable 1 1 9 DO NOT use worn or damage leads plugs or connections Immediately replace or have repaired by a qualified Electrician These particular compressors are supplied without a mains plug Follow the instructions below reg...

Page 2: ...r taken in by the compressor air in Air out is always less than air in due to losses within the compressor 2 INTRODUCTION SPECIFICATION 3 Keep children and unauthorised persons away from the working area 7 DO NOT disassemble compressor for any reason The unit must be checked by qualified personnel only 7 DO NOT use the compressor outdoors or in damp or wet locations 7 DO NOT operate within the vic...

Page 3: ...nk rises and that the compressor stops automatically when the maximum pressure is reached This value is written on the specification plate and may take in excess of 5 minutes The compressor will now operate automatically The pressure switch fig 5 stops the motor when the maximum tank pressure is reached and restarts it when pressure falls below the minimum threshold approximately 2bar 29psi less t...

Page 4: ...eat or if necessary replace the seal 3 Air leaks from tank body or tank welds Internal corrosion caused by infrequent tank draining or non permitted modifications to tank Cannot be repaired DISCONTINUE USE IMMEDIATELY 4A Motor stops and will not restart Thermal cut out has operated Allow unit to cool for 30 minutes before restarting 4B Motor stops or stalls and will not restart Supply breaker has ...

Page 5: ...Original Language Version Jack Sealey Limited 2013 SAC32055B SAC32775B Issue No 1 01 06 13 ...