background image

NOTE:   

  Efficiency of the dehumidifier is influenced by the air outside the room. For operating efficiency, try to avoid opening and closing the   

 

windows and doors. For best performance, operate the dehumidifier within the usable operating temperature. 

5.3.    

OPERATION

5.3.1. 

  

Plug the unit in to the mains socket, a beep will be heard when inserting the plug.

5.3.2.   

Press the “ON/OFF” switch and the operation light will illuminate, the humidity display will light to display the previous set humidity.    

 

The initial setting for humidity is 60%, after 3 seconds the display will show the current humidity. 

5.3.3. 

  

Press the humidity up or down buttons to adjust to the desired humidity required. 

 

If the required humidity is 3% below the current humidity the unit will start automatically, if the set humidity is 3% more than the current  

 

humidity the dehumidifier will automatically stop.

5.3.4.   

When setting the humidity to less than 30%, the unit will run continuously and the display will read “CO”.

5.3.5.   

To shut the dehumidifier down press the “ON/OFF” switch.  

 NOTE: 

If the humidity setting is greater than the current humidity the unit will not run.

 

‰

    WARNING!

 The fan motor and compressor must run for at least 3 minutes while dehumidifying. 

 

8

  

DO NOT

 start the dehumidifier immediately after shutting down, allow 3 minutes before restarting.

5.4.    

TIMER  FUNCTION

5.4.1.   

To set Timer for power ON mode, with the unit in power OFF state, press the Timer button (fig.4.6). The Timer ON LED (fig.4.1) will  

 

flicker and the current set time will be displayed. Use the Increase/ Decrease buttons (fig.4.10, fig.4.11) to set the required value to

 

between 0 and 24 hours. After 10 seconds the selected value is set and the Timer ON led will flicker.

5.4.2.   

To set the Timer for power OFF mode, with the unit in power ON state, press the Timer button (fig.4.6). The Timer OFF LED (fig.4.1)  

 

will flicker and the current set time will be displayed. Use the Increase/ Decrease buttons (fig.4.10, fig.4.11) to set the required value to  

 

between 0 and 24 hours. After 10 seconds the selected value is set and the Timer OFF led will flicker.

5.5.    

DEFROSTING 

 

   

5.5.1.   

The defrosting device works automatically at an interval of approximately every 30 minutes for a duration of approximately 5 minutes  

 

when the coil temperature is tested to be <= minus 1

o

C.

 

The dehumidifying function will stop during the defrosting operation.

 DO NOT

 disconnect the plug or turn off the unit during the 

 

defrosting operation. The defrosting led light (fig.4.7) will light up.

 NOTE:

 This dehumidifier does not have a cooling function, it produces heat during the operation and room temperature will rise 

 

by 1°C to 4°C. The temperature gets higher while it is operated in a closet, or similar. Furthermore, room temperature will rise because  

 

doors and windows are closed and heat is produced from other appliances in the room and from sun radiation.

5.6.    

EMPTYING THE WATER COLLECTION TANK

  

5.6.1. 

  

During the dehumidifying operation, water is collected in the water collection tank. When the tank is full of water, the dehumidifier stops 

 

operating automatically and the warning buzzer beeps twice. The unit will not restart until water collection tank has been emptied. 

5.6.2. 

  

Open the door and remove water collection tank from the dehumidifier by pulling it gently outwards by holding the sides of the tank.  

5.6.3. 

  

Hold the tank by the handle and carry it carefully to an emptying point.

5.6.4. 

  

Remove the plug at the bottom of the tank and slowly empty the water out of the tank.

5.6.5. 

  

Replace the drain plug and refit the tank in the dehumidifier, making sure it is properly back in place as the unit will not restart if it is    

 

not fitted correctly.

5.7.    

CONTINUOUS  DRAINING

5.7.1. 

  

If there is a place suitable for draining, continuous draining can be carried out. The continuous operation enables the dehumidfying    

 

operation  to continue uninterrupted. See Section 5.1.

6.  MAINTENANCE

6.1. 

  

CLEANING THE AIR FILTER

6.1.1.   

The dehumidifying capacity is lowered when the air cleaning filter becomes clogged.

6.1.2.   

Open the front door of the unit.

6.1.3.   

Lift up the filter element from the bottom and lift out of the holder.

6.1.4. 

  

To dislodge the dust from the filter, use a vacuum cleaner or tap it lightly.

6.1.5. 

  

If the filter is very dirty, wash it carefully in water with a neutral detergent, then rinse well with clean water and leave until dry.

6.1.6.   

To refit the air filter locate the top of the element into the locating bracket at the top of the door and then locate the lower section into  

 

the lower bracket.

6.1.7. 

  

Close the door of the dehumidifier. 

6.2. 

  

STORAGE

6.2.1.   

Unplug the unit, bundle the power cord, and hang the bundled cord at the back of the unit.

S

DH50110V   Issue 2   12/07/2021

Original Language Version

© Jack Sealey Limited

ITEM OPERATION

1

Timer Indicator

2

Temperature Indicator

3

D

ehumidification Indicator

4

Humidity Indicator

5

O

N/OFF Control

6

Time Set Control

7

Defrosting Indicator

8

Air Speed Indicator

9

W

ater Full Indicator

10

Increase Control

11

Decrease Control

1

2

3

4

5

6

7

8

9

10

11

  fig.4

Summary of Contents for SDH50110V

Page 1: ... and check all connections to ensure that none are loose 9 Ensure that the voltage marked on the appliance matches the power supply to be used 8 DO NOT pull or carry the appliance by its power supply lead 8 DO NOT pull the plug from the socket by the power cable 8 DO NOT use worn or damaged cables plugs or connectors Immediately have any faulty item repaired or replaced by a qualified electrician ...

Page 2: ... the appliance Cleaning and user maintenance shall not be made by children without supervision WARNING If the power cord is damaged it must be replaced by a professionally trained person 2 INTRODUCTION Powerful dehumidification capacity extracts up to 50 litres of water per day Removes excess moisture from air preventing build up of mildew and mould Features auto defrost function which activates i...

Page 3: ...tandby state the LED displays the Full Water signal and the dehumidifier will alarm When the water tank is emptied and put in place again the dehumidifier can continue its performance 5 1 2 CONTINUOUS DRAINAGE As shown in Fig 3 to restore the performance of the water tank you need to take out the water tank and mount the drain pipe Note When using continuous drainage the drainage pipe shall not be...

Page 4: ...during the defrosting operation The defrosting led light fig 4 7 will light up NOTE This dehumidifier does not have a cooling function it produces heat during the operation and room temperature will rise by 1 C to 4 C The temperature gets higher while it is operated in a closet or similar Furthermore room temperature will rise because doors and windows are closed and heat is produced from other ap...

Page 5: ... entire machine is defrosting Wait for the completion of defrosting cycle Unfavourable dehumidifying effect If the air inlet outlet is obstructed Remove the obstacle If the door and window are open Close the door and window If the indoor temperature is too low Don t run the dehumidifier Heavy noise If the ground is firm and flat Resettle the dehumidifier Dehumidifier is stood precariously Resettle...

Reviews: