background image

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions 

and properly maintained, give you years of trouble free performance.

IMPORTANT: 

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND 

CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO 

MAY CAUSE DAMAGE OR PERSONAL INJURY, AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR 

FUTURE USE.

Original Language Version

SFF04        Issue: 1 - 15/01/13

© Jack Sealey Limited

Instructions for:

Desk Fan Mini 4" 230V

Model No: 

SFF04

  1.  SAFETY  INSTRUCTIONS

1.2.  GENERAL SAFETY

 

Disconnect the fan from the mains power when not in use and before servicing or performing any maintenance.

 

Use the fan in dry areas only. Do not use in wet or areas with high condensation such as showers, pools etc. 

 

WARNING! 

If a fan falls into water or other liquid, immediately switch off  and disconnect from the mains power supply. Do not touch the    

  fan until the mains power supply has been disconnected.

 

Always disconnect the fan from the power supply when moving it from one location to another and ensure fan is stood on a level surface.

 

The fan air flow is powerful. Before use ensure that there is nothing nearby that will be damaged or displaced by the stream of air.

 

Keep the fan clean and maintained in good condition. For motor service contact an authorised service agent.

 

Use recommended parts only. Unapproved parts may be dangerous, and will invalidate your warranty.

 

DO NOT

 operate the fan where there are explosive or flammable gases, fumes or other hazardous substances.

 

DO NOT 

stand the fan on the power cable. 

 

DO NOT

 insert any objects through the fan guard.

 

DO NOT 

cover the fan when in use.

 

DO NOT

 immerse the fan in water or any other liquid.

 

DO NOT

 allow children to operate the fan.

 

DO NOT

 stand the fan where it may be knocked over or off a surface, or where the lead may cause a person to trip.

 

DO NOT

 use the fan outdoors.

 

DO NOT

 modify speed control or attempt to fit any additional external speed control device to the fan.

 

When not in use place the fan in its original box, or otherwise cover, to protect from dust and store in a safe, dry, childproof  

 

 location.

 NOTE:

 This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities   

  or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by  

  a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.

 

RECOMMENDED FUSE

RATING: 3A

1.1. 

ELECTRICAL SAFETY

  

WARNING!

 It is the responsibility of the owner and the operator to read, understand and comply with the following:

You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and any other 

connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices. A 

Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. We also recommend that a Residual Current 

Device (RCD) is used. It is particularly important to use an RCD with portable products that are plugged into a supply which is not protected by 

an RCCB. If in any doubt consult a qualified electrician. You may obtain a Residual Current Device by contacting your Sealey dealer. 

You must

 also read and understand the following instructions concerning electrical safety.

1.1.1. The 

Electricity at Work Act 1989 

requires all portable electrical appliances, if used on business premises, to be tested by a qualified  

 

electrician, using a Portable Appliance Tester (PAT), at least once a year.

1.1.2. The 

Health & Safety at Work Act 1974 

makes owners of electrical appliances responsible 

 

for the safe condition of those appliances and the safety of the appliance operators. 

If in

 

any doubt about electrical safety, contact a qualified electrician.

1.1.3.  Ensure that the insulation on all cables and on the appliance is safe before connecting it

 

to the power supply. See 1.1.1. and 1.1.2.  and use a Portable Appliance Tester.

1.1.4.  Ensure that cables are always protected against short circuit and overload.

1.1.5.  Regularly inspect power supply cables and plugs for wear or damage and check all

 

connections to ensure that none is loose.

1.1.6. 

Important:

 Ensure that the voltage marked on the appliance matches the power supply 

 

to be used and that the plug is fitted with the correct fuse - see fuse rating at right.

1.1.7. 

DO NOT

 pull or carry the appliance by the power cable.

1.1.8. 

DO NOT 

pull the plug from the socket by the cable.

1.1.9. 

DO NOT

 use worn or damaged cables, plugs or connectors. Immediately have any faulty item 

 

repaired or replaced by a qualified electrician. When an ASTA/BS approved UK 3 pin plug is

 

damaged, cut the cable just above the plug and 

dispose of the plug safely. 

 

Fit a new plug according to the following instructions (UK only).

 

a)  Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

 

b)  Connect the BROWN live wire to the live terminal ‘L’.

 

c)  Connect the BLUE neutral wire to the neutral terminal ‘N’.

 

d)  After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable outer  

 

 

  insulation extends beyond the cable restraint and that the restraint is tight.

 

Double insulated products, which are always marked with this symbol      , are fitted with live (brown) and neutral (blue) wires only.    

 

To rewire, connect the wires as indicated above - 

DO NOT

 connect either wire to the earth terminal.

1.1.10.  Products which require more than 13 amps are supplied without a plug. In this case you must contact a qualified electrician to ensure  

 

that a suitably rated supply is available. We recommend that you discuss the installation of an industrial round pin plug and socket    

 

with your electrician.

1.1.11.  If an extension reel is used it should be fully unwound before connection. A reel with an RCD fitted is preferred since any appliance    

 

plugged into it will be protected. The cable core section is important and should be at least 1.5mm², but to be absolutely sure that    

 

the capacity of the reel is suitable for this product and for others which may be used in the other output sockets, we recommend the    

 

use of 2.5mm² section cable. If extension reel is to be used outdoors, ensure it is marked for outdoor use.