background image

9L MANUAL/AIR VACUUM OIL & FLUID 

EXTRACTOR

Model no: 

S01168

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these 

instructions, and properly maintained, give you years of trouble free performance.

IMPORTANT:

 PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE 

THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR 
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

1.  SAFETy  

 

‰

  WARNING!

 ensure Health & Safety, local authority, and general workshop practice regulations are strictly adhered to when using this    

 equipment.

 

‰

   WARNING!

 disconnect the extractor from the air supply before changing accessories, servicing or performing any maintenance.

 

‰

  

WARNING! 

ensure that you wear protective clothing, gloves, goggles, face mask as appropriate for the fluid being extracted.

 

9

   Keep the extractor clean and maintain it in good condition (use an authorised service agent).

 

9

   Replace or repair damaged parts. Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.

 

9

   Check extractor connections and fittings before use. When the extractor is turned on check that there are no leaks.

 

9

   ensure that the extractor’s tank capacity exceeds the amount of fluid to be collected.

 

9

   Avoid unintentional starting of the extractor and ensure that the end of the suction tube is fully submerged in the fluid before operating.

 

9

   Keep the work area clean, uncluttered and ensure there is adequate lighting.

 

9

  Maintain correct balance and footing. ensure the floor is not slippery and wear non-slip shoes.

 

9

   Keep children and unauthorised persons away from the working area.

 

9

   dispose of waste fluids in accordance with local authority regulations.

 

9

   Use only to extract engine or transmission oils, or similar non-corrosive fluids. Unit may also be used for the transfer of water. 

 

‰

   WARNING! DO NOT

 allow uncontrolled discharge of fluids thus polluting the environment.

 

8

  DO NOT 

pull or yank any pipes or hoses and 

DO NOT

 attempt to move the extractor by pulling the hose.

 

8

  DO NOT

 leave the extractor operating unattended.

 

8

  DO NOT 

use to extract hazardous or harmful chemicals, solvents, petrol, diesel, kerosene, alkaline or acids. If by chance such fluids  

  are used in the unit, it must be immediately drained and thoroughly cleaned. Use with prohibited fluids will invalidate your warranty.

 

8

  DO NOT

 store fluids in the extractor’s tank. After extracting fluid, it must be emptied into an approved receptacle as soon as possible.

 

8

  DO NOT

 dismantle, tamper or adapt the extractor for any purpose other than for which it is designed.

 

8

  DO NOT

 store in areas of high temperature, direct sunlight, rain or snow.

 

8

 

DO NOT

 leave the unit in a pressurised state. 

 

‰

  

WARNING!

 When the extractor’s tank contains liquid that is under pressure 

DO NOT

 remove or insert the extension tube connector into  

  the inlet/outlet fitting as this may result in a sudden discharge of liquid that could be dangerous.

 

9

  Always press the pressure relief button before connecting or disconnecting the extension tube.

 

‰

  d

O NOT

 direct the air line at yourself or others.

2.  INTRODUCTION

 

9l Capacity device constructed from composite materials. Uses manual pump or compressed air supply to generate vacuum.  

 

 

Suitable for the extraction of all types of engine, transmission and lubricating oil from cars, motorcycles, marine engines, stationary  

 

engines and industrial machinery. Also suitable for low viscosity fluids such as water. Supplied with Ø4, Ø6, Ø8 x 1000mm suction  

 

probes, Ø10 x 1000mm extension tube and 1200mm brake bleed tube. Uses probes to extract engine oil through the dipstick tube.

3.  SpECIFICATION

Model: ........................................................................

S01168

Capacity: ........................................................................... 9 l 

Suction probes:   

 Ø4x1000, Ø6x1000, Ø8x1000mm, 1200mm Brake bleed tube

extension hose: .............................................

Ø10 x 1000mm

Supply: ................................................................

90psi(5cfm)

4.  AIR SUppLy

 

 

When using a workshop air supply, the recommended hook-up is shown below.

4.1. 

  

ensure that the air valve (see fig.3) is in the “off” position before connecting to the air supply.

4.1.1. 

  

You will require an air pressure and an air flow (cfm) according to the specification. 

 

‰

   WARNING! 

ensure the air supply is clean and does not exceed the pressure quoted. 

 

‰

   WARNING!

 Too high an air pressure and/or unclean air will shorten the life of the extractor due to excessive wear and may be  

 

  dangerous, causing damage and/or personal injury. 

S

01168    Issue 1   25/10/19

Original Language Version

© Jack Sealey limited

Refer to 

instructions

Wear eye 

protection

 Wear protective 

gloves

Summary of Contents for Siegen Tools S01168

Page 1: ...8 8 DO NOT leave the extractor operating unattended 8 8 DO NOT use to extract hazardous or harmful chemicals solvents petrol diesel kerosene alkaline or acids If by chance such fluids are used in the unit it must be immediately drained and thoroughly cleaned Use with prohibited fluids will invalidate your warranty 8 8 DO NOT store fluids in the extractor s tank After extracting fluid it must be em...

Page 2: ... shown below in fig 3 5 1 5 Connect an airline to the coupling at the back of the air valve and turn the air valve off as shown above Adjust the air source to 90psi with an air flow of 5cfm 5 1 6 To commence draining the sump turn the air valve on and press the button to start the suction as shown below in fig 4 When the fluid being drained reaches the top of the tank the unit will shut down autom...

Page 3: ...ervoir Fill the reservoir to its maximum mark 6 2 2 Identify the brake bleeding tube which has a flexible plastic brake nipple connector at one end and a rubber adaptor at the other 6 2 3 Connect the brake bleeding tube to the top of the fluid extractor s tank by pushing the black rubber adaptor into the fluid inlet coupling 6 2 4 Push the flexible plastic brake nipple connector onto the brake nip...

Page 4: ... the environment When the product becomes completely unserviceable and requires disposal drain any fluids if applicable into approved containers and dispose of the product and fluids according to local regulations Note It is our policy to continually improve products and as such we reserve the right to alter data specifications and component parts without prior notice Important No Liability is acc...

Reviews: