• 8 •
9. MAINTENANCE INSTRUCTIONS
1. After use and before performing maintenance, unplug and disconnect
the unit.
2. Use a dry cloth to wipe all battery corrosion and other dirt or oil from
the battery clamps, cords, and the outer case.
3. Do not open the unit, as there are no user-serviceable parts.
10. STORAGE INSTRUCTIONS
1. Charge battery to full capacity before storage.
2. Store this unit at temperatures between -20°C – +60°C.
3. Never completely discharge the battery.
4. Charge after each use.
5. Charge at least once every month, if not in frequent use, to prevent
over-discharge.
11. TROUBLESHOOTING
PROBLEM
SOLUTION
The jump starter’s display will
not turn on.
Make sure the unit is charged.
Connect to AC power, using the provided
wall charger, to reset.
Make sure the ON/OFF switch is set to
the ON position.
The display backlight is
flashing.
The unit is too hot or cold. The light will stop
flashing when the condition is removed.
The jump starter will not
recharge.
Make sure to use only the provided wall
charger.
The jump starter turns on, but
won’t jump start my vehicle.
Make sure you have pressed the smart
cable’s button.
Verify the charge level of the jump starter is
at least 40%.
Do not attempt to jump start your vehicle
more than three consecutive times. If
the vehicle still does not start, consult a
qualified service technician.
The green LED on the smart
cable does not light when its
button is pressed.
Check connections.
If an LED is flashing, refer to the table
below. When the condition is corrected,
the smart cable will automatically reset.