2.  INTRODUCTION & SPECIFICATION

one of the quietest professional compressors on the market, noise level is the same as a refrigerator at only 40dB (at 1mtr). In comparison, the 
noise levels for a vacuum cleaner, dishwasher and washing machine are between 70-80dB. suitable for many applications including nail/staple 

guns, air brushes, blow guns, tyre inflators and any other small operated air tools.

3.  PREPARATION & ASSEMBLY

4. TOOL SELECTION

Model No

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SSQC0903P . . . . . . . . . . . .SSQC2405P. . . . . . . . . . . . . SSQC2409

Motor Output

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.3hp . . . . . . . . . . . . . . . . . 0.5hp . . . . . . . . . . . . . . . . .0.92hp

Voltage/Phase

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230V/1ph . . . . . . . . . . . . . . 230V/1ph . . . . . . . . . . . . . . 230V/1ph

Air Displacement

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.88cfm . . . . . . . . . . . . . . . 1.77cfm . . . . . . . . . . . . . . . . 3.53cfm

Max Free Air Delivery

. . . . . . . . . . . . . . . . . . . . . . . . . . 0.65cfm . . . . . . . . . . . . . . . . 1.3cfm . . . . . . . . . . . . . . . . . 2.6cfm

Receiver Capacity

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9ltr . . . . . . . . . . . . . . . . . . 24ltr . . . . . . . . . . . . . . . . . . .24ltr

Max Pressure

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116psi / 8bar . . . . . . . . . . . 116psi / 8bar . . . . . . . . . . . . 116psi / 8bar

Dimensions

 - length x Width x Height . . . .330 x 330 x 470mm . . . . . . 400 x 400 x 600mm . . . . . . 360 x 650 x 550mm

Weight

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18kg . . . . . . . . . . . . . . . . . . 27kg . . . . . . . . . . . . . . . . . . 50kg

Noise Level

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40dB.a . . . . . . . . . . . . . . . . 40dB.a. . . . . . . . . . . . . . . . 42dB.a

Original Language Version

ssQc0903P, ssQc2405P, ssQc2409    Issue: 3 (sP) -  22/07/13

  

WARNING! The compressor is supplied without any lubricating oil in the pump see para. 3.4.

3.1

 remove compressor from packaging and inspect for any shortages or damage. If anything is found to be missing or damaged contact  

 

your supplier. 

3.2

 confirm that the mains voltage corresponds with the voltage shown on the compressor data plate.

3.3

 the compressor should be installed on a flat surface, or one that does not exceed  15

°

 either transversely or longitudinally, and should  

 

be in a position that allows good air circulation around the unit.

3.4 

IMPORTANT! Remove air filter (fig.1) and the oil filler cap from the pump (fig.1A) and fill with synthetic compressor oil until   

 

the level is up to the centre of the sight glass (fig.1B). Replace the filler cap. 

 

DO NOT ATTEMPT TO RUN THE COMPRESSOR UNTIL THIS HAS BEEN DONE.

3.5 

Ensure that the air vent in the oil filler/breather is free from debris. If the air vent is blocked, pressure can build up in the   

 

crankcase causing damage to the compressor and possible personal injury.

3.6

 screw/insert air filter (fig.1) into inlet port.

  

IMPORTANT Take care when selecting tools for use with the compressor. Air  tool manufacturers normally express the volume  

 

of air required to operate a tool in cubic feet per minute (cfm). This refers to free air delivered by the compressor (‘air out’)   

 

which varies according to the pressure setting. Do not confuse this with the compressor displacement which is the air taken  

 

in by the compressor (‘air in’). ‘Air out’ is always less than ‘air in’ - due to losses within the compressor - and so it is   

 

important that, before choosing equipment, you study the ‘Free Air Delivery’ figures shown in the Specifications above. 

ssQc0903P

ssQc2405P, ssQc2409

fig.1

3

 use the compressor in a well ventilated area and ensure that it is placed on a firm, level surface.

DO NOT

 use this product to perform a task for which it is not designed.

DO NOT

 deface the certification plate attached to the compressor tank. 

DO NOT

 cover the compressor or restrict air flow around the machine whilst operating.

   DANGER! DO NOT direct the output jet of air towards people or animals.

DO NOT

 operate the compressor without an air filter.

DO NOT

 allow anyone to operate the compressor unless they have received full instructions.

  

WARNING! The air tank is a pressure vessel and the following safety measures apply:

DO NOT tamper with the safety valve and DO NOT modify or alter the tank in any way and DO NOT strap anything to the tank.

DO NOT subject the tank to impact, vibration or to heat and DO NOT allow contact with abrasive or corrosive materials.

DO drain condensation from tank daily and inspect inside walls for corrosion every three months. Have a detailed tank   

 

inspection carried out annually. The tank shell must not fall below the certified thickness at any point.. 

  

WARNING! If an electrical fuse blows, ensure that it is replaced with one of identical type and rating. 

 

When not in use, disconnect from the mains, vent the tank and store the compressor in a safe, dry, childproof location.

Summary of Contents for SSQC0903P

Page 1: ... not protected by an rccB If in any doubt consult a qualified electrician You may obtain a residual current Device by contacting your sealey dealer You must also read and understand the following instructions concerning electrical safety 1 1 1 the Electricity at Work Act 1989 requires all portable electrical appliances if used on business premises to be tested by a qualified electrician using a Po...

Page 2: ... crankcase causing damage to the compressor and possible personal injury 3 6 screw insert air filter fig 1 into inlet port IMPORTANT Take care when selecting tools for use with the compressor Air tool manufacturers normally express the volume of air required to operate a tool in cubic feet per minute cfm This refers to free air delivered by the compressor air out which varies according to the pres...

Page 3: ...e switch box indicates the pressure inside the main tank NOT the pressure supplied to the air equipment which is shown on the gauge attached to the regulator should the pressure in the main tank exceed the pre set maximum pressure the safety valve will activate the safety valve is adjacent to the regulator WARNING For this reason DO NOT tamper with or adjust the switch or the safety valve NOTE Whe...

Page 4: ...og the pump intake filter and may cause internal damage to pump motor components Please note that any parts damaged by any type of contamination will not be covered by warranty 6 MAINTENANCE Maintenance Procedure Once a Week Once a Month Once a Year check the oil level is in the middle of the sight glass add more synthetic compressor oil if needed 4 Drain the water collected in the air outlet filt...

Page 5: ...restart current overload trip has operated remove from main supply and Investigate and remedy reason for overload 5 compressor stops and does not restart motor failure contact authorised service agent 6a compressor does not stop at max pressure Pressure switch fault contact authorised service agent 6B compressor does not stop at max pressure filter clogged Head gasket or valve fault replace filter...

Reviews: