2. INTRODUCTION
F
eatures tilt and swivel head for optimum air circulation. Remote control operation and fully guarded fan blades for ease of use and extra
safety. Smooth running motor powers both fan blades and head oscillation. Timer function allows user to pre-set running time between 30
minutes - 4 hours. Sleep mode for gradual reduction of fan speed. Supplied with wall bracket for quick and easy installation.
3. SPECIFICATION
Model No:.......................................................SWF16WR.V5
F
an diameter: ......................................................
400mm(16”)
Height: .......................................................................
500mm
Speeds: ................................................................................3
Supply: ...........................................................................
230V
M
aximum Fan Flow Rate (F):
..............................
44.7 m³/min
F
an Power Input (P): .......................................................
45W
S
ervice Value (SV):
.......................................
1.14 (m³/min)/W
Standby Power Consumption .....................................
0.20 W
F
an Sound Power Level (Lwa): ................................
67 dB(A)
M
aximum Air Velocity (c):
.........................................
2.80 m/s
M
easurement Standard for Service Value:
...
IEC 60879:1986
4. ASSEMBLY
4.1.
Remove the rear grill mounting nut by turning it counter-clockwise.
4.1.1.
Place the rear grill onto the motor housing aligning the 3 raised knobs on the top of the motor
housing with the three holes on the grill. fig.1.
4.1.2.
Place the rear grill mounting nut over spindle and tighten clockwise. fig.2.
4.1.3.
Align the blade with the shaft and slide into position. Secure in position by tightening the blade knob
counter-clockwise. fig.3.
4.1.4.
Align the front grill with the rear grill and push the clips together to secure .
4.2.
WALL MOUNTING
4.2.1.
Position the wall mounting bracket on the wall where the fan will be
mounted. Ensure the blades are move than 2.3 m above floor.
4.2.2.
Use the bracket as a template and mark the two holes ready for drilling.
fig.4.
4.2.3.
Use either fixings supplied or proprietary wall fixings, ensure fixings chosen
are suitable for the type of wall and the weight of the fan.
4.2.4.
Drill two holes suitable for the wall fixings.
4.2.5.
Attach bracket to wall.
4.2.6.
Slide fan back plate over bracket to hang fan from wall.
4.3.
BATTERY INSTALLATION
4.3.1.
To use remote control, open the cover on the back of the remote control
unit fig.5, and insert 2 x AAA batteries ensure they are correctly position
according to polarity see diagram in battery compartment.
5. OPERATION
5.1.
Position the fan on a level and dry wall surface.
5.2.
Plug the power cable into the socket and switch on the power supply.
5.3.
FAN CONTROL PANEL
5.3.1.
LED TIMER :- Visual display of time setting can only be set from remote control. fig.6.
5.3.2. LED FAN SPEED :- Visual display of speed. fig.6.
5.3.3.
FAN ON/SPEED CONTROL BUTTON :- Press to switch on, press again to scroll trough speed settings. fig.6.
5.3.4.
OSCILLATING BUTTON :- Press to switch on oscillation, press again to switch off oscillation. fig.6.
5.3.5.
STOP BUTTON :- Switches fan off. fig.6.
5.4.
REMOTE CONTROL
5.4.1.
FAN ON/SPEED CONTROL BUTTON :- Press to switch on, press again to scroll trough speed settings. fig.7.
5.4.2.
OSCILLATING BUTTON :- Press to switch on oscillation, press again to switch off oscillation. fig.7.
5.4.3.
STOP BUTTON :- Switches fan off. fig.7.
5.4.4.
TIMER BUTTON :- Press to select working time, 1,2,4, or 7.5 hours indicated by the LED lights on the fan control panel (ie. by
adding the selected fig. displayed above LED.) fig.7.
fig.1
fig.2
fig.3
fig.4
fig.5
fig.6
fig.7
Original Language Version
© Jack Sealey Limited
S
WF16WR.V5 Issue 1 18/02/2021