2.  INTRODUCTION & SpECIFICATIONS

A range of pond pumps suitable for creating garden water features such as fountains and waterfalls. They also provide the important 

functions of filtration and water circulation which are necessary to maintain healthy plant and fish life. Each pump is supplied with 5 

fountain heads (fig.3) and 10m of cable.

3.  OpERATING INSTRUCTIONS

 

WARNING! Ensure that you read, understand and apply the safety instructions in Section 1.

3.1.   Start-up.

3.1.1.  Place the pump on a flat level surface which is raised from the bottom of the pond. This prevents the pump from clogging too quickly.

3.1.2.  You may use the pump lying on its side. You should however, make sure that the motor axis is horizontal, otherwise the shaft will be subject   

 

to increased wear.

3.2. 

Cascade Fountain Mode.

3.2.1.  When installing the pump in the pond, make sure that the fountain head projects above the water surface. Please refer to 

 

fig 1 and ensure the regulating valve fig 1.1 is set at o° (turned all the way to the right). The delivery heights and diameters in fig 1   

 

correspond to a condition in which the fountain head is placed 50mm above the water surface. 

Technical Data.

Model: 

Wpp2300 

Wpp2650 

Wpp3500

 

Power Consumption: 

55W 

75W 

95W

Max. Head: 

2.3mtr 

2.7mtr 

3.0mtr

Max. flow Rate: 

2300ltr/h 

2650ltr/h 

3500ltr/h

Max. Submersion Depth: 

2.3mtr 

2.7mtr 

3.0mtr

Power Cable: 

10mtr 

10mtr 

10mtr

Max. Temp. of the Pumped fluid: 

35°C 

35°C 

35°C

Input: 

230V 

230V 

230V

Protection Type: 

IP68 

IP68 

IP68

Fig 1

1

2

  Refer to Fig 1.

 

Wpp2300 

Wpp2650 

Wpp3500

  Diameter of 1st stage “C” 

1100mm 

1200mm 

1320mm

  Diameter of 2nd stage “B” 

800mm 

1000mm 

1100mm

  Delivery head of 1st stage “D” 

700mm 

900mm 

990mm

  Delivery of second stage “E” 

1100mm 

1450mm 

1595mm

  Max. delivery head “f” 

1300mm 

1800mm 

1980mm

  Refer to Fig 1

 

Wpp2300 

Wpp2650 

Wpp3500

  Distance from pump outlet to fountain head “G”   240-395mm  255-410mm  255-410mm

  Distance from pump base to fountain head “H”    365-520mm  380-535mm  380-535mm

3.3 

Fountain Heads.

3.3.1.  A selection of fountain heads are supplied with the pump (fig 3). Choose the desired style and install onto the outlet pipe. 

3.4. 

Fountain and Water Spout Connection.

3.4.1.  Additional water spectacles can be connected to the water spout connection (fig.1.2) with a hose of 19mm OD .

3.4.2.  To open the spout connection, turn the regulating valve (fig 1.1) anticlockwise between 0-90° to adjust the flow between    

 

 

the spout and the fountain head. 

3.5. 

Water Spout Only.

3.5.1.  Turn the regulating valve all the way anticlockwise to 90°. All the water flow will now be through the water spout.

Fig 2