background image

MODEL NO

 . .Units of measurement/spec. .

XRC25  . . . . .XRC40  . . . .XRC55  . . . .XRC90

Electrical power  . . . . . . . . . . .W  . . . . . . . . . . . . . 650 . . . . . . . . .800  . . . . . . . .831 . . . . . . . .1205
Max. current . . . . . . . . . . . . . .A  . . . . . . . . . . . . . .3 . . . . . . . . . . .4  . . . . . . . . . .5  . . . . . . . . . .7

Drying capacity . . .30

O

80%RH  (L 

24H)  . . . . .23  . . . . . . . . . .42  . . . . . . . . .53  . . . . . . . . .88

 . . . . . . . . . . . . . .27

O

60%RH  (L 

24H)  . . . . .11  . . . . . . . . . .27  . . . . . . . . .37  . . . . . . . . .54

 . . . . . . . . . . . . . .12

O

70%RH  (L 

24H)  . . . . .5 . . . . . . . . . . .7 . . . . . . . . . .18  . . . . . . . . .22

Working range (Humidity)  . . .%.  . . . . . . . . . . .40 -100  . . . . . .40 -100  . . . . .40 -100  . . . . .40 -100

Working range (Temperature)

O

C.  . . . . . . . . . . . .5 - 30  . . . . . . .5 - 30 . . . . . . .5 - 30 . . . . . . .5 - 30

Air flow  . . . . . . . . . . . . . . . .m

3

/h  . . . . . . . . . . . .350  . . . . . . . . .500  . . . . . . . .600  . . . . . . . .800

Cooling gas type  . . . . . . . . .Gas  . . . . . . . . . . .R407C  . . . . . .R407C . . . . . .R407C . . . . . .R407C

Cooling gas mass  . . . . . . . . .(g)  . . . . . . . . . . . . .350  . . . . . . . . .500  . . . . . . . .525  . . . . . . . .700

Compressor  . . . . . . . . . . . . . . . . . . . . . . . . .Reciprocating  . . . .Rotary  . . . . . .Rotary  . . . . . .Rotary

Container full LED  . . . . . . . . . . . . . . . . . . . . . . . .Yes  . . . . . . . . .Yes  . . . . . . . .Yes  . . . . . . . .Yes

Compressor protection  . . . . . . . . . . . . . . . . . . . . .Yes  . . . . . . . . .Yes  . . . . . . . .Yes  . . . . . . . .Yes

Filter  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Yes  . . . . . . . . .Yes  . . . . . . . .Yes  . . . . . . . .Yes

Tank capacity  . . . . . . . . . . .Litres  . . . . . . . . . . . .10  . . . . . . . . . .10  . . . . . . . . .10  . . . . . . . . .10

Weight  . . . . . . . . . . . . . . . . .Kg  . . . . . . . . . . . . .34  . . . . . . . . . .51  . . . . . . . . .57  . . . . . . . . .63

Dimensions  . . . . . . . . . . . . .mm . . . . . . . . .455x370x635  .540x460x860  .970x670x650  .985x700x700

3. TRANSPORT & ASSEMBLY

4. INSTALLATION

2. INTRODUCTION & SPECIFICATIONS

The XRC commercial/industrial dehumidfier range is designed to remove moisture from the air in high humidity environments such as cellars,

kitchens, bathrooms etc. The units are designed for continuous operation either manually or automatically if connected to an optional hygrostat

sensor. The internal cooling units use the more environmentally friendly R407C cooling gas. All units have an air filtering system, electronic

control, a defrost system for compressor protection, and an automatic stop when the water collection tank is full. The units are easy to move

and robustly constructed.

3.1

Transit. 

The unit should be transported in a vertical position or inclined on the handle 

side. If it has been transported in a horizontal position allow the unit to stand in the 

vertical position for about one hour to allow the lubrication to be rebalanced. 

3.2

Check that the unit has not been damaged in any way and that all parts are present. If

there are any problems contact your local Sealey dealer.

3.3

Packaging.

Packaging materials such as cartons, polythene bags etc should not be 

left within the reach of children as such items could be dangerous to them. Dispose of

all packaging materials in accordance with local authority requirements.

3.4

Assembly.

Assemble the main handle to the body of the unit as shown in fig.1 using 

the fixing screws provided.

fig.1

fig. 4

4.1

It is important that the air inlet and air outlet remain unobstructed at all times.

4.2

The following minimum safety distances are recommended between the unit and 

walls or objects. 

Ÿ

Ÿ

 

 

Minimum distance from air inlet - 0.6m.

Ÿ

Ÿ

 

 

Minimum distance from air outlet - 3.0m.

4.3

Ideally the unit should be installed in the centre of the room to guarantee the best 

possible air circulation. 

4.4

DO NOT

install the unit near heat sources. Keep windows and doors closed whilst the 

unit is operating.

4.5

Dual voltage models (XRC55 & 90).

The dual voltage models are designed to run off 

either a 230V 50Hz supply or a 110V 50Hz supply. To select the required voltage do 

the following:

Ÿ

Ÿ

 

 

Remove the two fixing screws holding the voltage selector cover plate.

Ÿ

Ÿ

 

 

Move the selector switch to the required voltage.     

Ÿ

Ÿ

 

 

Reverse the cover plate and screw it back into position.

4.6

Water drain. 

Drained water can be collected and eliminated in 2 ways:

A)

Using the tank supplied as shown in fig.2. The tank must be emptied when the  yelow ‘tank full’ LED lights up. Switch the unit off 

before emptying the tank and disconnect the mains plug. Remove the tank carefully to avoid spills and empty it. Slide the tank back 

into the unit ensuring that the level sensor is correctly placed within the tank.

NOTE: When the dehumidifier is switched off and then restarted, the compressor will not start to run immediately but will cut in again 

after some minutes. This waiting time protects the compressor from repeated starts at short intervals.

B)

Water may be removed by connecting a plastic hose with an internal diameter of 14mm to the hose holder in the drain 

compartment. ( Plastic hose not supplied.) See fig.3.

Special attention should be paid not to raise the outlet of the hose over the drain level of the unit. (Max height 1ft, see fig.4) Failure to 

do this will result in water spillage and flooding of the unit.

4.7

Connection of a Hygrostat

. A hygrostat control is also available as an optional accessory. This enables the unit to function automatically.

The remote hygrostsat will be located near the air inlet and is connected to the unit via a jack plug on the units control panel

fig. 2

fig. 3

XRC25,40,55,90 - 1 - 060503

Reviews: