GAS SYSTEM
General – The yacht is equipped with an LPG unit. The
LGP system for the cooker is installed in accordance
with the European standard EN ISO 10239. The
operating pressure of the LPG system is 30mbar.
Please heed the special regulations of the state under
which flag you are driving!
The gas cylinder locker for the max. 1.8 kg gas
cylinders is situated in the cockpit on the port side.
The cylinder box is ventilated outboard. Possible water
that has penetrated is drained through the opening.
NOTICE
Keep the ventilation opening free of blockages.
Check regularly the state of the opening!
WARNING
Never:
•
Change the state of the cylinder box.
•
Create openings to the inside of the boat
from the cylinder box.
•
Install electrical systems or conduits in the
cylinder box.
•
Use the cylinder box as a stowage space.
WARNING
Do not modify the craft’s LPG system. Installation,
alterations and maintenance shall be performed
by a competent person. Have the system
inspected at regular intervals or as required by
national requirements.
Please observe the following notes when operating it.
WARNING
If a leak is detected shut off the main LPG supply
valve and do not use LPG appliances..
Action in case of a smell of gas
If you smell gas, shut the valve of the gas cylinder and
ventilate the boat intensively. The presence of gas
fumes can be checked for by means of gas detectors.
Have a specialist examine and remedy the cause before
using the gas system again!
Notes on preventing malfunctions of the LPG unit:
•
LPG supply line valves and cylinder valves shall be
closed when appliances are not in use, before
refuelling and immediately in an emergency.
•
Make sure that the valves of the appliances are shut
before opening the valve of the cylinder!
•
Check the LPG unit for possible leakages before
each use:
Shut the valves of the appliance;
Open the valve of the cylinder;
Wait for stabilization from the pressure;
Shut the valve of the cylinder;
Watch on the manometer for 3 minutes; the pressure
should remain constant!
If pressure gauge reading falls, leak is present: do
not use LPG appliances!
WARNING
Do not use an installation that has leaked until
it has been inspected and repaired by a
competent person.
•
Manual leak testing with foam-producing, soapy
water or detergent solutions (with appliance burner
valves closed and cylinder and system valves open);
foam-producing solutions for leak detection on gas
installations in accordance with EN 14291 meet
these requirements;
•
If there are leakages, shut the valve of the cylinder
and have the system repaired by a specialist before
using the appliance again.
Summary of Contents for S450
Page 1: ... ...
Page 2: ... ...
Page 6: ... 6HDOLQH 2ZQHU V 0DQXDO 3DJH ...
Page 55: ... 75 6HDOLQH 2ZQHU V 0DQXDO 3DJH AC PANEL 10 10 16 10 16 16 16 16 16 10 16 10 ...
Page 81: ... 7 1 6HDOLQH 2ZQHU V 0DQXDO 3DJH ...
Page 82: ... 6HDOLQH 2ZQHU V 0DQXDO 3DJH DATA SHEETS DIAGRAMS PRINCIPAL DIMENSIONS ...
Page 84: ... 6HDOLQH 2ZQHU V 0DQXDO 3DJH DECK PLAN ...
Page 86: ... 6HDOLQH 2ZQHU V 0DQXDO 3DJH SYSTEM CONTROL POINTS ...
Page 88: ... 6HDOLQH 2ZQHU V 0DQXDO 3DJH EQUIPMENT LOCATION ACCOMMODATION SPACE ...
Page 90: ... 6HDOLQH 2ZQHU V 0DQXDO 3DJH GAS SYSTEM LAYOUT ...
Page 92: ... 6HDOLQH 2ZQHU V 0DQXDO 3DJH FIRE PROTECTION SYSTEM 3 4 1 5 6 8 1 2 7 8 8 1 ...
Page 94: ... 6HDOLQH 2ZQHU V 0DQXDO 3DJH BLACK WATER SYSTEM ...