ENGLISH
1. VERIFY THE CONTENT OF THE PACKING
PAR56 LED lamp ~12V
Cable gasket 7, 9 and 13 mm
Screws
O’ring
Manual of installation and maintenance
Wedging blocks
2. GENERAL CHARACTERISTICS
This lamp has been designed to be used immerged in fresh water. It is a Class III electric apparatus
with very low safety voltage ~12V.
This lamp complies with IP68 degree of protection and must be installed in a PAR56 niche at a
maximal immersion depth of 1 meter.
This lamp complies with international standards for lights, especially the EN 60598-2-18 standards,
lights for swimming pools and similar applications.
This lamp must be connected to a power supply cable with a minimum section of 2x1mm².
3. INSTALLATION
For a correct installation, the power socket which feeds the installation lamp will have to possess a
device of protection by residual current with a maximal intensity of 30 mA.
This projector will be only connected to a ~12V security transformer with double winding. Another type
of transformer is prohibited.
The power of this transformer will be always higher than the power of all projectors connected.
The manufacturer is not responsible in any circumstances for assembly, installation or start-up of any
electric components which have been inserted or handled at locations other than its own premises.
4. ASSEMBLY and REPLACEMENT
Before any operation, turn OFF the power supply to lamp
4.1 Traditional mounting
Remove existing bulb from housing to dry place and unscrew its back support
Unscrew the gland to make the cable free
Unscrew the 2 connectors from the back of the lamp
Change the O-ring of the projector
Connect the new LED lamp with no use of the back cap and nut, lube the lamp cup,
screw on the back support, the gland and replace the projector in its niche.
Control the sealing of the support and turn ON the power supply
4.2 Ecoproof mounting
Remove the cap and nut at the back part of the lamp
Select the gasket corresponding to the section of the cable gain and screw the cable
with the connectors placed into the lamp cup
First screw the cap and then, the nut with adapted tools
Place the lamp in the projector crown
Use 3 wedging blocks and screw them with the crown by using the projector screws
Control the sealing of the assembly and turn ON the power supply
5. MAINTENANCE
This lamp does not require any type of maintenance work. When the red LED of the remote controller
does not light anymore, replace the 12V MN23 type alkaline battery.
In case of improperly working, please contact our customer service or the customer service of our