background image

Page 2

GENERAL INFORMATION

The DL76 is a battery-powered data logger that can be used 

with any Seametrics flowmeter. It stores pulses for up to 3 

years, depending on the user-selected frequency of reading. 

Indicator lights on the unit flash to indicate when it is func

-

tioning and when the battery is low.

The DL76 can be factory-mounted on the meter or remotely 

mounted. Housings are rugged cast aluminum, gasketed for 

environmental protection.

When a DL76 logger is placed into operation, it is easily set 

up using a laptop computer. Data is also retrieved from the 

DL76 by means of a laptop and can be analyzed on the laptop 

or easily loaded on a desktop computer for analysis.

FlowInspector software (ordered separately) is required 

for 

the downloading, storing, viewing, graphing, charting and print-

ing of data in several formats. 

FlowInspector requires a PC with Windows 98, NT, 2000, XP, 

Vista, or Windows 7; CD-Rom drive; 800 x 600 screen resolu

-

tion; serial port or USB/serial adapter; and a Seametrics DC3 

data cable. FlowInspector comes in versions compatible with 

up to 4, up to 16, or 17+ dataloggers.

FEATURES

DL76

Data Logger

Data

Port

Active
Replace

Battery

Bright status LEDs flash to indicate 

logger activity and battery life

Sturdy gasketed cover with potted 

electronics

Cable to meter (wall mount only)

SPECIFICATIONS*

*Specifications subject to change • Please consult our website for current data (www.Seametrics.com).

Size C 3.6 Vdc lithium battery (included)

Estimated life is 3-5 years depending on usage.

0˚ to 130˚ F (-18˚ to 54˚C)

mL, liter, gallon, Imperial gallon, cubic foot, cubic meter, million gallon

Seconds, minutes, hours, days

Liter, gallon, Imperial gallon, cubic foot, cubic meter, million gallon,

acre-foot, acre-inch, megaliter, thousand-gallon

        Capacity          

at        

Sampling Interval

 

11 days  

at 

15 seconds

 

22 days  

at 

30 seconds

 

44 days  

at 

60 seconds

 

6 months  

at 

240 seconds

 

1 year  

at 

480 seconds

 

3 years  

at 

1450 seconds

500 Hz

Low battery; Power

Selectable options (Stop or Overwrite)

10 minutes/month (.02%)

Power

Battery Life

Temperature

Rate Units 

    Volume

 

    Time

Total Units

Data Storage Capacity

Maximum Input Frequency

Indicators

Memory Wraparound

Clock Accuracy

Removable foot brackets for remote 

mounting (wall mount model only)

Data port connector for Seametrics  

DC3 serial or USB data collection cable

Protective data port cap (shown open)

Reviews: