WMP-SERIES INSTRUCTIONS

Maintenance

There are no user-serviceable parts in the WMP-Series 

meters except the batteries in the WMP104.

Battery Replacement.

  When  the  “low  bat”  indicator 

appears, the batteries should be changed. Either six AA 

alkaline  cells  are  required,  or  two  C  lithium  cells  with 

integrated  wiring  harness,  depending  on  power  option 

ordered with meter. 

To change the batteries, first remove the four screws which 

hold the top cover in place. Be careful not to lose the 

washers. Move the top cover to one side and remove the 

foam retainer which covers the battery tray or pack.

• 

For units with AA alkaline batteries, remove the old 

bat teries from the battery tray and replace them 

with fresh ones, taking care to fol low the polarity 

indicators in the battery tray.

• 

For units with the optional C lithium batteries, 

carefully unplug each of the two battery wiring 

harness connectors. Slip the batteries out from 

under the elastic retainer, and replace them with 

the new batteries. Reconnect each of the two wiring 

harness connectors. The connectors are indexed for 

correct installation. 

Replace  the  foam  retainer,  and  then  put  the  top  cover 

back in  place. Replace the four screws and washers, and 

then tighten them securely using cross-pattern to evenly 

compress the gasket. 

Troubleshooting

MAINTENANCE and TROUBLESHOOTING

Problem

Probable Causes

Things to try…

Blank Display (WMP101)

No power to unit

Check power supply; check wiring

Blank Display (WMP104)

Batteries dead or misinstalled

Check polarity; replace batteries

Reading “-EP-”

Empty or partly filled pipe or 

excessive air pockets or foaming

Rearrange piping to ensure full pipe

Flow but no flow rate reading

Heavily coated electrodes

Remove meter and wipe electrodes

Warning! 

Use Extreme Caution not to pinch wiring 

or other assembly parts under the 

housing seal—this may cause an ingress 

of water, voiding the product warranty.

Environmental and Safety Note 

Take care to dispose of all batteries in 

accordance with Federal, State, and Local 

regulations.

Summary of Contents for WMP Series

Page 1: ...PROUDLY MADE IN THE USA C e rtified Compa n y ISO 9001 2008 WMP Series Plastic Bodied Magmeter Instructions 2 inch 1 inch 3 inch...

Page 2: ...ng is made of rugged powder coated diecast aluminum It can be fitted with cross drilled screws and seal wire for tamper evidence Flow rate and total can be displayed in a variety of units customer sel...

Page 3: ...Million Gallons Day Cubic Feet Second Cubic Feet Minute Liters Second Liters Minute Million Liters Day Cubic Meters Minute Cubic Meters Hour Acre Feet Acre Inch Gallons Gallons x 1000 Cubic Feet Lite...

Page 4: ...5 50 4 625 9 50 3 25 2 00 5 50 2 03 6 03 4 625 10 75 4 40 3 00 7 30 7 30 2 625 3 Inch Dimensions Dimensions shown without the Seametrics WMP Fitting Kit Flow Range 1 2 3 Gal Min Liter Sec Gal Min Lite...

Page 5: ...P NOTE Above installation instructions are for WMP101 104 200 2 and WMP101 104 300 3 only The WMP101 104 100 1 is provided with integrated NPT female threaded ends INSTALLATION Piping Conditions It is...

Page 6: ...lem Allows air pockets to form at sensor Better Installation Ensures full pipe Possible Problem Post valve cavitation can create air pocket Better Installation Keeps pipe full at sensor Air can be tra...

Page 7: ...umulated total in the units for which it was ordered The top line is the total the bottom line is the rate and indicators give the units ac ft GPM for instance Empty or partially full pipe is automati...

Page 8: ...efully unplug each of the two battery wiring harness connectors Slip the batteries out from under the elastic retainer and replace them with the new batteries Reconnect each of the two wiring harness...

Reviews: