Summary of Contents for WMP-Series

Page 1: ...WMP Series PLASTIC BODIED MAGMETER instructions W M P S eries P L A S T I C B O D I E D M A G M E T E R i n str u ctio n s 2 inch 1 inch ...

Page 2: ...Flow rate and total can be displayed in a variety of units customer selected and factory set The WMP Series is used for tracking flow rate and total flow in usage monitoring applications for instance in compliance with regulatory requirements These would include wells industrial wastewater heap leach mining discharge cooling tower deduct metering turf and landscape applications and other water rec...

Page 3: ...unregulated power supply 18 Vdc may damage the meter due to AC line input voltage fluctuation 6 each AA alkaline cells replaceable Estimated life is 1 year with meter in typical use or 3 years dry 2 each C lithium batteries replaceable Estimated life is 3 years with meter in typical use or 10 years dry Current sinking pulse opto isolated 24 Vdc at 10 mA max 1 gal pulse out or 1 liter pulse out dep...

Page 4: ...eametrics Follow the diagram below to make the connections Position This is an all position meter which can be installed either vertically or horizontally register up down or angled However entrained air or solids may make some positions preferable to others See the position diagram for guidance Less Ideal Air bubbles and sediment on the electrodes can affect accuracy Intermittent air bubbles pass...

Page 5: ...deal Air can be trapped Not Ideal Post valve cavitation can create air pocket Recommended Allows air to bleed off Recommended Keep pipe full at meter for accuracy Recommended Keeps pipe full at meter for accuracy WMP WMP WMP WMP WMP WMP 1X 5X 5X Expanded Pipe Swirling Flow Partially Open Butterfly Valve 1X WMP WMP Reduced Pipe 4 ...

Page 6: ...the display Then connect the pulse output Operation Grounding WMP101 For best performance especially in chemically noisy environments the gray ground wire and the bare drain wire should be connected together and to a good earth ground as close to the meter as possible Metal pipe and fittings in contact with the fluid should also be bonded to the same earth ground with corrosion resis tant connecti...

Page 7: ... in place Be care ful not to lose the wash ers Move the top cover to one side and remove the foam retainer which covers the battery tray or pack For units with AA alkaline batteries remove the old bat teries from the battery tray and replace them with fresh ones taking care to fol low the polarity indicators in the battery tray For units with C lithium batteries carefully unplug each of the two ba...

Page 8: ...LT 65200337 B 4 12 10 Seametrics Incorporated 19026 72nd Avenue South Kent Washington 98032 USA P 253 872 0284 F 253 872 0285 1 800 975 8153 www seametrics com ...