background image

CONTENTS

Introduction ........................................................................2

Warranty ..............................................................................2
Safety Rules..........................................................................2
Installation ........................................................................3-5
Service .................................................................................5
Repair Parts.......................................................................6-7

INTRODUCTION

Please read our instructions before you install and use your
new pump; this will help you obtain full value and good ser-
vice from it. It will also help you avoid needless service costs
that result from causes we cannot control and cannot cover
in our warranty.

Carefully read and follow all safety instructions in this
manual or on pump.

This is the safety alert symbol. 

When you see this

symbol on your pump or in this manual, look for one of the
following signal words and be alert to the potential for per-
sonal injury!

warns about hazards that will cause serious

personal injury, death or major property damage if ignored.

warns about hazards that can cause serious

personal injury, death or major property damage if ignored.

warns about hazards that will or can cause

minor personal injury or property damage if ignored.

The word 

NOTICE 

indicates special instructions which are

important but not related to hazards.

Electrically powered sump pumps normally give many years
of trouble-free service when correctly installed, maintained,
and used. However, unusual circumstances (interruption of
power to the pump, dirt/debris in the sump, flooding that ex-
ceeds the pump’s capacity, electrical or mechanical failure in
the pump, etc.) may prevent your pump from functioning
normally. To prevent possible water damage due to flooding,
consult your local Sears store about installing a secondary
sump pump or a DC backup sump pump. See  “Service”,
Page 5, for information about common sump pump prob-
lems and remedies.

1.

Read these Instructions and Safety Rules carefully.

Failure to follow them could cause serious bodily injury
and/or property damage.

2. Check your local Electrical and Plumbing Codes before

installing pump. You must comply with their rules.

Do not use in explosive atmospheres.

Pump water only with this pump. 

Do not touch an operating motor. Modern motors are de-
signed to run at high temperatures.

Risk of electric shock. Proceed as fol-

lows if pump needs servicing:

A. Disconnect power to pump outlet box before

pulling pump cord plug!

After plug is pulled, let

pump cool for 20 minutes before attempting to work
on it.

B. Take extreme care when changing fuses.

To re-

duce the chance of fatal electrical shocks, 

DO NOT

stand in water or put your finger in the fuse socket.

C. Ground 

the electrical outlet box.

D. Use only a grounded outlet

for cord plug.

E.

Do not handle pump motor with wet hands or when

standing on wet or damp surface, or in water.

3. Never run pump dry. To do so can damage internal parts,

overheat the pump (which can cause burns to people
handling or servicing the pump), and will void the war-
ranty!

FIRE HAZARD – Do not store or rest ob-

jects on or near motor or switch linkage. Keep all
flammable objects or liquids away from motor.

4. This pump is recommended for use in permanent instal-

lations only. Do not install on clay, earth, or sand surfaces.

Pump must be level (column must be verti-

cal) when operating. If motor is tilted, internal start/run
switch may overheat and damage motor.

2

FULL TWO YEAR WARRANTY ON CRAFTSMAN SUMP PUMP

For two years from the date of purchase, Sears will repair or replace this sump pump, free of charge, if defective in materials or
workmanship. This warranty does not cover repairs on replacement parts necessary because of abuse or negligence including
failure to install, adjust and operate this pump according to the instructions in the owner’s manual.

FULL ONE YEAR WARRANTY ON SEARS SUMP PUMP

For one year from the date of purchase, Sears will repair or replace this pump, free of charge, if defective in materials or work-
manship. This warranty does not cover repairs on replacement parts necessary because of abuse or negligence including failure
to install, adjust and operate this pump according to the instructions in the owner’s manual.

LIMITATION OF LIABILITY

SEARS WILL NOT BE LIABLE FOR LOSS OR DAMAGE TO PROPERTY OR ANY INCIDENTAL OR CONSEQUENTIAL LOSS OR
EXPENSE FROM PROPERTY DAMAGE DUE DIRECTLY OR INDIRECTLY FROM THE USE OF THIS PRODUCT.

Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion
may not apply to you.

WARRANTY SERVICE IS AVAILABLE BY SIMPLY CONTACTING THE NEAREST SEARS SERVICE CENTER/DEPARTMENT IN
THE UNITED STATES. 

This warranty applies only while the product is in the United States.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

Sears, Roebuck and Co., Dept. 817 WA, Hoffman Estates, IL 60179

RULES FOR SAFE INSTALLATION AND OPERATION

Summary of Contents for 390.303300

Page 1: ...ons Before First Use of This Product Save This Manual For Future Reference Sears Roebuck and Co Hoffman Estates IL 60179 U S A Safety Instructions Operation Installation Service Repair Parts PRINTED IN U S A PEDESTAL SUMP PUMP Form No F642 9611 Rev 4 2 97 CRAFTSMAN Model No 390 303490 SEARS Model No 390 303300 ...

Page 2: ...t B Take extreme care when changing fuses To re duce the chance of fatal electrical shocks DO NOT stand in water or put your finger in the fuse socket C Ground the electrical outlet box D Use only a grounded outlet for cord plug E Do not handle pump motor with wet hands or when standing on wet or damp surface or in water 3 Never run pump dry To do so can damage internal parts overheat the pump whi...

Page 3: ...e around the pump to allow the switch free movement as the sump water level changes Do not install on clay earth or sand Risk of flooding If a flexible discharge hose is used pump may move around in sump when motor starts If it moves far enough so that the switch hits the side of the sump the switch may stick and prevent pump from starting Make sure that pump is secured so that it cannot walk arou...

Page 4: ...e switch arm Its weight holds the switch off 2 When the water rises in the sump the float lifts the switch rod The buoyancy will push the switch arm up and turn the switch on 3 When the water is pumped out of the sump the float drops down again The weight of the float will allow the rod and switch arm to lower and turn the drainer switch off DO NOT ALLOW PUMP TO RUN DRY Pump should not be allowed ...

Page 5: ...t light the electrical circuit is faulty consult a licensed electrician 2 Pump starts but blows fuses trips circuit breakers After disconnecting power to pump remove it from sump Remove the plate from the bottom of the pump and make sure that the impeller turns freely Remove any debris obstructing impeller If pump still does not oper ate correctly return it to your nearest SEARS Service Department...

Page 6: ...h Cord and Switch 2 U30 932ZP Set Screw 3 Required 3 RP0005257 Shaft 4 RP0005246A Column 5 PS1 25P Volute 6 PS5 21P Impeller 7 PS4 17P Base Plate 8 U30 934ZP Screw 10 16 x 5 8 Hex Head 8 Required 9 S19 14GP Rod Guide 10 S23 23 Rod Bushing 4 Required 11 S28 21P Float 12 S28 18SS Rod 13 2773 Switch 14 U17 318 Cord and Plug F642 9611 Owner s Manual Not illustrated If motor fails replace entire pump ...

Page 7: ...Screw 4 Required 3 RP0005257 Shaft 4 S15 37SS Column 5 S1 32B Volute 6 S5 13P Impeller 7 PS4 17P Base Plate 8 U30 539SS Screw 8 32 x 1 2 Hex Head 8 Required 9 RP0005249 Rod Guide 10 RP0005248 Rod Bushing 2 Required 11 FT0013 63 Float 12 RP005168S Rod 13 2773 Switch U17 318 Cord and Plug U78 130P 1 1 2 x 1 1 4 Reducer Bushing F642 9611 Owner s Manual Not illustrated May be purchased locally If moto...

Page 8: ...tenance Agreement or to inquire about an existing Agreement call 9 am 5 pm Monday Saturday 1 800 827 6655 M A I N T E N A N C E A G R E E M E N T America s Repair Specialists REPAIRSERVICES America s Repair Specialists REPAIRSERVICES America s Repair Specialists REPAIRSERVICES OWNER S MANUAL Model No 390 303300 390 303490 The model number of your Pedestal Sump Pump will be located on the side of t...

Reviews: