background image

7

ASSEMBLY

BREAK-IN PROCEDURES

If repairing or replacing cord or plug, the grounding wire
must be kept separate from the current-carrying wires.
Never connect the grounding wire to a flat blade plug ter-
minal. The grounding wire has insulation with an outer sur-
face that is green with or without yellow stripes.

If these grounding instructions are not completely under-
stood, or if in doubt as to whether the compressor is prop-
erly grounded, have the installation checked by a qualified
electrician.

1. Attach the handle to the compressor saddle by inserting

the handle inside the compressor saddle and lining up
the two bolt holes on each side.  Install the four screws,
two on each side. Tighten securely.

2. Install one shoulder bolt and one nut for each wheel.

Tighten securely. The compressor will sit level if the
wheels are properly installed.

3. Clean and dry underside of air tank leg opposite wheels.

Remove the protective paper strip from the adhesive
backed rubber foot strip.  Attach the rubber 

foot strip to

the bottom of leg. Press firmly into place.

THE  WHEELS AND HANDLE DO NOT
PROVIDE  ADEQUATE  CLEARANCE,
STABILITY  OR   SUPPORT  FOR
PULLING THE UNIT UP AND  DOWN
STAIRS OR STEPS.  THE UNIT MUST
BE LIFTED,  OR  PUSHED  UP A RAMP.

This portable air compressor is equipped with a cord having
a grounding wire with an appropriate grounding plug.  The
plug must be used with an outlet that has been installed  and
grounded in accordance with all local codes and ordinances.
The outlet must have the same configuration as the plug.  DO
NOT USE AN ADAPTER.

Inspect the plug and cord before each use. Do not use if
there are signs of damage.

IMPROPER GROUNDING CAN RESULT
IN ELECTRICAL SHOCK.

Do not modify the plug that has been
provided. If it does  not fit the available
outlet, the correct outlet should be
installed by a qualified technician.

Installing Wheels, Handles, Rubber
Foot Strip

Locate the air compressor in a clean, dry and well ventilated
area.  The air filter must be kept clear of obstructions which
could reduce air delivery of the air compressor.  The air com-
pressor should be located at least 12" away from the wall or
other obstructions that will interfere with the flow of fresh
intake and cooling air.

Location of  the Air Compressor

This unit needs no lubrication or oiling.

Lubrication and Oil

Grounding Instructions

RISK OF ELECTRICAL SHOCK.  In the
event of  a short circuit, grounding
reduces the risk of shock by provid-
ing an escape wire for the electric
current. This air compressor must be
properly grounded.

Summary of Contents for 919.72512

Page 1: ...e Number can be found on the bar code label on the rear of the air tank 3 The Serial Number can be found on the bar code label on the rear of the tank 4 The Tank Registration Number is located on the...

Page 2: ...raftsman Air Compressor warranty gives you specific legal rights and you may have other rights which vary from province to province Sears Canada Inc Toronto Ont M5B 2B8 WARRANTY 2 SAFETY GUIDELINES 3...

Page 3: ...cause the tank to rupture Modifications to the air tank will cause it to weaken Hot Parts The metal compressor components such as manifold tubes etc become hot when the air compressor is running If yo...

Page 4: ...do not use accessories that contain aluminum or galvanized parts You must either change the material you intend to spray or use only stainless steel spray equipment Certain materials you are spraying...

Page 5: ...ator gauges and handle This air compressor requires no oil Now you can enjoy all the benefits of having an air compressor without ever having to purchase add or change oil Your air compressor can be u...

Page 6: ...cut out pressure setting the safety valve will protect the tank against high pressure by popping out at its factory set pressure slightly higher than the pressure switch cut out setting Tools Needed...

Page 7: ...AND DOWN STAIRS OR STEPS THE UNIT MUST BE LIFTED OR PUSHED UP A RAMP This portable air compressor is equipped with a cord having a grounding wire with an appropriate grounding plug The plug must be u...

Page 8: ...number decreases 10 AWG and 8 AWG may also be used DO NOT USE 14 OR 16 AWG a three wire extension cord that has a three connector grounding plug and a three slot receptacle that will accept the plug...

Page 9: ...pressure reaches cut out pressure 5 Open the regulator by turning it clockwise Adjust the regulator to the correct pressure setting Your compressor is ready for use 6 Always operate the air compressor...

Page 10: ...pressor pull the ring on the safety valve to make sure that the safety valve operates freely If the valve is stuck or does not operate smoothly it must be replaced with the same type of valve Risk of...

Page 11: ...release valve when there is pressure in the tank and the com pressor is shut off Remove and clean or re place check valve DO NOT OVERTIGHTEN Air tank must be replaced Do not repair the leak Return com...

Page 12: ...tions Return to Sears Service Center for inspection or replacement if necessary Bleed the line by pushing the lever on the pressure switch to the O position if the valve does not open replace it Inspe...

Page 13: ...rdered from any Sears Service Center and most Sears stores If the parts you need are not stocked locally your order will be electronically transmitted to a Sears Repair Parts Distribution Center for h...

Page 14: ...quette appos e l arri re du r servoir d air 3 Le num ro de s rie indiqu sur l tiquette appos e l arri re du r servoir d air 4 Le num ro d enregistrement du r servoir indiqu sur la plaque signal tique...

Page 15: ...ion 10 Moteur 10 Entreposage 10 GUIDE DE D PANNAGE 11 SCH MA APPAREIL 13 LISTE DES PI CES 14 SCH MA BLOC COMPRESSEUR 15 LISTE DES PI CES BLOC COMPRESSEUR 16 NOTES 17 POURCOMMANDERLESPI CESDERECHANGE 1...

Page 16: ...que dans des locaux bienventil setd pourvusdevapeursd essenceoude solvant Nepasfairefonctionnerlecompresseurpr s des locaux de vaporisation Ne pas r gler ter ni modifier la soupape de s ret ni le pre...

Page 17: ...erlebecoulegicleurversunepersonne ou une partie du corps Toujoursporterdesgantsetdeslunettesprotectrices quand on utilise le compresseur d air Arr ter toujours le compresseur avant de brancher ou de d...

Page 18: ...res de gonflage Un r gulateur de pression est g n ralement utilis dans ce genre d applications Desfiltres aird shydrateurssuppl mentairesqui liminent les impuret s et l humidit contenues dans l air do...

Page 19: ...f r duit l amp rage au d marrage Soupape de s ret Si le pressostat n arr te pas le compresseur au point d arr t la soupape de s ret prot ge l unit contre des pressions excessives en faisant vacuer l a...

Page 20: ...les deux vis de chaque c t et bien serrer 2 Pour monter les roues fixer un boulon paulement et une rondelle pour chaque roue Bien serrer Si les roues sont bien mont es le compresseur sera de niveau 3...

Page 21: ...La longueur de la rallonge ne doit pas d passer 50 pi La rallonge doit tre en bon tat Directives de rodage Cette proc dure n est requise qu une seule fois avant la mise en service initiale du compres...

Page 22: ...l Suivre scrupuleusement les tapes 3 et 5 suivantes chaque fois qu on utilise le compresseur ATTENTION L aircomprim peutcontenirdel eaudeconden sation Ne pas vaporiser avec de l air comprim non filtr...

Page 23: ...i la cause des observationssuivantes 1 Le moteur n atteint pas sa vitesse ni sa puissance maximales 2 Le fusible saute au d marrage Les lumi res baissent au d marrage et demeurent faibles pendant le f...

Page 24: ...etenued fectueux La capacit du compresseur est insuffisante la demande Filtre air bouch Mettrelelevierdupressostat lapositiond arr t O Si le compresseur ne s arr te pas d brancher l alimentation lectr...

Page 25: ...Lecompresseurd marreautomatiquementaussit t que la pression du r servoir baisse au niveau du point de d clenchement du pressostat 1 V rifier fusible ou disjoncteur Remplacer ou r armer Ne pas utiliser...

Page 26: ...es magasins Sears Si le magasin Sears auquel s adresse le client n a pas en stock les pi ces d sir es la commande sera transmise par ordinateur un centre de distribution de pi ces de rechange Sears po...

Reviews: