Indicator LED
LED on: option memorised.
LED off: option not memorised.
Flashing LED: option selected.
MAIN MENU
LED Ref.
LED Off
LED On
1) MONO
Monostable
Impulse 1 sec.
2) TEMP.
Timer = OFF
Timer = ON
3) I. CMD
Relay Output NO
Relay Output NC
1) MONO
(Monostable Operation / Impulse 1 sec.)
The control unit is supplied with the Monostable operational mode
enabled (MONO LED OFF), meaning that the relay will activate every time
that the sensor determines that there is no light, and will deactivate in the
presence of light. When needing an Impulse type of functioning, meaning
that the relay is only activated for one second each time that the sensor
determines that there is no light, programming must be completed in the
following way: position the SEL key on the flashing of MONO LED then
press the SET key, the MONO LED will simultaneously switch on perma-
nently and the programming is completed. Repeat the procedure to
restore the previous configuration.
2) TEMP.
(Timer Function enabled / disabled)
The control unit is supplied with the Timer functioning disabled (TIMER
LED OFF).
When the device needs to be used with the timed function, meaning that
the control relay is active for the programmed amount of time after the
sensor has been activated.
Proceed as follows: position the SEL key on TIMER LED and press the
SET key to start programming, at the same time the TIMER LED will start
to double flash; every double flash of the TIMER LED corresponds to an
increase of 30 minutes up to a maximum of 12 hours (24 double flashes),
press the SET key until the desired time is reached; at the same time the
selected value is saved and the TIMER LED will stay on.
It is possible to repeat the operation in case of an incorrect programming.
Displaying the programmed Time
When verifying the previously programmed Time, it is possible to display
it in the following way: with the SEL key position yourself on TIMER LED,
the LED will start to double flash for the number of times equal to the
Time programmed in the memory (every double flash of the TIMER LED
corresponds an increase of 30 minutes), (
example: 4 TIMER LED flashes
= 120 minutes).
3) I. CMD
( Inversion of NO / NC control functioning )
The control unit is with a Normally Open output operational mode (LED I.
CMD OFF).
When needing an inverted mode of operation, with the control output set
at Normally Closed, proceed as follows: position the SEL key on the
flashing of LED I. CMD then press the SET key, the LED I. CMD will simul-
taneously switch on permanently and the programming is completed.
Repeat the procedure to restore the previous configuration.
R
ESET
In case it is necessary to reset the device to default factory settings,
press the SEL and SET keys together so that all indicator LEDs switch on
and then immediately off at the same time.